Business Type:
Trading Company
Business Range:
High and low voltage appliance, Instrument and apparatus, Industrial control products
Establishment:
2010
R&D Capacity:
OEM, ODM, OwnBrand(LF/E)
OEM/ODM Service
Sample Available

Limit Switch, Limitting Switch, Wld2 manufacturer / supplier in China, offering Wld2 Limit Switch, 380VAC, Wld2 Limit Switch, Ce Proved Limit Switch, ISO9001 Proved Switch, Float Switch Lfs-3, Lfs-3 Water Level Controller Lfs-3 Tank Level Switch, 3 Meters Float Switch, Ce Proved Float Switch, Lrt8-S2 Asymmetric Cycler Time Relay, AC220V Lrt8-S2 Asymmetric Cycler Time Relay, Ce Proved Time Relay, ISO9001 Proved Time Relay and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Capacitor China Lf111-a 10kvar Power Capacitor Power Capacitor 10kvar Powr Capacitor

China Lf111-a 10kvar Power Capacitor Power Capacitor 10kvar Powr Capacitor

Get Latest Price
Min. Order / Reference FOB Price
10 Pieces US $15.20/ Pieces
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Aluminum Electrolytic Capacitor
Application: General Purpose, AC / Motor, Power
Packaging Type: Through Hole
LF111-A 10kvar 440V epoxy resin dielectric Power Capacitor for reactive power supply
Wax type dielectrical shunt Power capacitor
All inductive devices operating in the AC system convert electrical energy from the power supply system into mechanical energy and thermal energy, which is called active power.
Reactive power: In order to achieve this transformation, it is necessary to establish magnetic fields in the equipment, and these magnetic fields are related to another form of electrical energy provided in the power supply system, which is called reactive power energy.
The existing forms of reactive power are as follows:
Reactive Power (Transformer, Motor, etc.) Required by Inductance Circuit
Reactive Power (Cable, etc.) Required by Capacitance Circuit
Active power KW = P, reactive power KVAR = Q, inductance reactive power + Q, capacitor reactive power - Q
Apparent power KVA = S
As long as the user has electric load such as motor transformer on site, he will consume reactive power, so the demand for reactive power is just needed for the user.
What is the power factor?
The power factor is the active power KW. The closer the power factor is to the maximum value of 1, the more favorable PF = P (KW)/S (KVA) is for users and power supply departments.
For example, if the power factor is only 0.7, if the power factor is not up to the standard, there will be a penalty for the electricity charge. The power factor reaches 0.95. If the power factor exceeds the assessment index, the power supply bureau will award a calendar.
Increase of efficiency
Correction of Power Factor to Improve Equipment Efficiency