Business Type:
Trading Company
Business Range:
High and low voltage appliance, Instrument and apparatus, Industrial control products
Establishment:
2010
R&D Capacity:
OEM, ODM, OwnBrand(LF/E)
OEM/ODM Service
Sample Available

Limit Switch, Limitting Switch, Wld2 manufacturer / supplier in China, offering Wld2 Limit Switch, 380VAC, Wld2 Limit Switch, Ce Proved Limit Switch, ISO9001 Proved Switch, Float Switch Lfs-3, Lfs-3 Water Level Controller Lfs-3 Tank Level Switch, 3 Meters Float Switch, Ce Proved Float Switch, Lrt8-S2 Asymmetric Cycler Time Relay, AC220V Lrt8-S2 Asymmetric Cycler Time Relay, Ce Proved Time Relay, ISO9001 Proved Time Relay and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Breaker & Protector Circuit Breaker China Lfw1 Air Circuit Breaker; 2000A Air Circuit Breaker; Fixed Type Air Circuit Breaker

China Lfw1 Air Circuit Breaker; 2000A Air Circuit Breaker; Fixed Type Air Circuit Breaker

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $680.00/ Pieces
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
LFW1 ACB Intelligent Universal air circuit breaker 2000A
1.1 Application scope

LFW1 Acb Intelligent Universal Air Circuit Breaker 2500A
LFW1 series air circuit breaker is suitable for the circuit of AC 50Hz/60Hz with rated service voltage 400V, 690V and rated service current up to 6300A.It is mainly used to distribute electric energy and protect circuits and electric equipment against over-load, under-voltage, short-circuit and single-phase earthing fault.

With intelligentized and selective protection functions, the breaker can improve the reliability of power supply, and avoid unnecessary power failure.The breaker is applicable for power stations, factories, mines (for 690V) and modern high- buildings, especially for the distribution system of intelligentized building.

1.2 Standard:IEC/EN 60947-2.

2.Operation conditions

2.1 Temperature condition:-5°C~40°C;The average value within 24h shall not exceed+35°C(special situation excluded);

2.2 Altitude:≤2000m;

2.3 Pollution grade:Grade 3;

2.4 Air conditions:

At mounting site, relative humidity not exceed 50% at the max temperature of +40°C, higher relative humidity is

Allowable under lower temperature,

RH could be 90% at +20°C, special measures should be

Taken to occurrence of dews;
Feature of Intelligent Air Circuit Breaker(ACB)
1. Rated AC current: 630A-6300A
2. Short-circuit breaking capacity: 80KA-120KA
3. Rated Voltage: under AC690V
4. Two Types: draw-out type and fixed type
5. Equipped with many types of intelligent controllers, of different functions.
6. Both the 3 Pole and 4 Pole air circuit breakers are available.
7. Standards: IEC60947-2, GB14048.2,CE.