Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, PayPal, WesternUnion, Small-amountpayment, MoneyGram
Main Markets:
North America, South America, Eastern Europe, Southeast Asia, Africa, Oceania, Mid East, ...
OEM/ODM Service
Sample Available

CO2 Laser Cutting Machine, CNC Laser Cutting Machine, Laser Angraving Machine manufacturer / supplier in China, offering MDF Wood Art Single or Dual Head Laser Cutting Machine in China, Nonmetal Large-Format Flexible Material Laser Cutting Machine, Cheaper Universal CO2 Laser Cutting Machine for Textile Cutter and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Optical Fiber, Cable & Wire Power Cable China Low Medium Voltage XLPE Insulated PVC Sheathed Copper Aluminum Conductor Sta Swa Steel Armored Electric Wire Power Cable

China Low Medium Voltage XLPE Insulated PVC Sheathed Copper Aluminum Conductor Sta Swa Steel Armored Electric Wire Power Cable

Get Latest Price
Min. Order / Reference FOB Price
1 Sets US $3500.00/ Sets
Local Area: Qingdao, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion, Small-amountpayment, MoneyGram
Voltage: Low and Medium Voltage Cable
Current: DC & AC
Insulation Material: PVC
Product Description

Low Voltage Cable
1. Application

1) The long-time permissible operation temperature of conductor shall not be higher than 70oC.
2) Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 160 oC.
3) The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0 oC.
If so, the cable should to be preheated.
4) Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame.
5) Light weight, perfect bending properties, installed and maintained easily and conveniently

2. Operating Characteristic

1) The rated voltage U0/U of cable is 0.6/1KV.

2) The long time allowable working temperature of conductor is 70 °C FOR cable with PVC insulation, 90 °C for cable with XLPE insulation.

3) The cable laying temperature is not less than 0°C, and the allowable bending radius of a cable is not less 20 times than cable overall diameter for single core unarmored cable, 15 times of that for single core armored, 12 times of that for 3 cores armored cable.
3.Cores and Nominal Cross Section Area:

Rated voltage 0.6/1kV Single core Basic parameter of Power CableNominal cross section mm2Thickness of insulation mmYJV,YJLVApproximate weight of cable kg/km Approximate weight of cable kg/kmThickness of sheath mmApprox. overall diameter of cable mmYJVYJLVInner covering mmThickness of steel tape mmThickness of sheath mmApprox. overall diameter of cable mmYJV62YJLV621.50.70.75.645 35 2.50.70.76.056 41 40.70.76.574 49 60.70.77.095 59 100.70.78.2139 79 160.70.79.1197 102 250.90.910.6293 143 0.90.21.814.0451 301 350.90.911.6386 178 0.90.21.815.0558 349 501.01.013.0507 225 0.90.21.816.4698 416 701.11.114.9708 300 0.90.21.818.3926 519 951.11.116.8959 394 0.90.21.820.01194 628 1201.21.218.51193 479 0.90.21.821.71450 737 1501.41.420.61470 590 0.90.21.823.61745 865 1851.61.622.81831 730 0.90.21.825.62122 1021 2401.71.725.72380 933 0.90.21.928.52706 1259 3001.81.828.32960 1144 0.90.21.930.93304 1488 4002.02.031.33755 1433 1.20.52.135.94494 2173

Rated voltage 0.6/1kV Two cores Basic parameter of Power CableNominal cross section mm2Thickness of insulation mmYJV,YJLVApproximate weight of cable kg/km Approximate weight of cable kg/kmThickness of sheath mmApprox. overall diameter of cable mmYJVYJLVInner covering mmThickness of steel tape mmThickness of sheath mmApprox. overall diameter of cable mmYJV62YJLV621.50.71.810.2114 96 0.90.21.812.8232 214 2.50.71.811.0141 111 0.90.21.813.6269 238 40.71.812.0181 132 0.90.21.814.6320 271 60.71.813.0228 156 0.90.21.815.6379 306 100.71.815.4331 211 0.90.21.818.0509 389 160.71.817.2458 268 0.90.21.819.8657 467 250.91.820.2672 371 0.90.21.822.8905 604 350.91.822.2873 455 0.90.21.824.81130 712 501.01.825.01140 574 0.90.21.827.61428 863 701.11.929.01592 775 1.20.22.033.62262 1445 951.12.032.62134 1000 1.20.22.237.42899 1765 1201.22.136.22660 1229 1.20.52.341.03504 2074 1501.42.340.43287 1522 1.20.52.445.04202 2437 1851.62.444.64073 1864 1.20.52.549.25079 2870 2401.72.650.45287 2384 1.40.52.855.66457 3554 3001.82.855.66567 2925 1.40.52.960.67822 4180 4002.02.961.48279 3622 1.40.53.166.69692 5034

Rated voltage 0.6/1kV Three cores Basic parameter of Power CableNominal cross section mm2Thickness of insulation mmYJV,YJLVApproximate weight of cable kg/km Approximate weight of cable kg/kmThickness of sheath mmApprox. overall diameter of cable mmYJVYJLVInner covering mmThickness of steel tape mmThickness of sheath mmApprox. overall diameter of cable mmYJV62YJLV621.50.71.810.7135 107 0.90.21.813.3259 231 2.50.71.811.5171 125 0.90.21.814.1304 259 40.71.812.6225 152 0.90.21.815.2370 297 60.71.813.7291 182 0.90.21.816.3449 341 100.71.816.3429 250 0.90.21.818.9618 438 160.71.818.2609 324 0.90.21.820.8820 534 250.91.821.4907 455 0.90.21.824.01154 703 350.91.823.61194 567 0.90.21.826.21466 840 501.01.826.61570 722 0.90.21.929.41891 1042 701.11.930.92208 983 1.20.22.135.72936 1711 951.12.135.02995 1294 1.20.52.239.63794 2093 1201.22.238.83741 1595 1.20.52.443.64642 2496 1501.42.343.14601 1953 1.20.52.547.95598 2950 1851.62.547.85738 2425 1.40.52.753.06851 3538 2401.72.754.07462 3107 1.40.52.959.28711 4356 3001.82.959.69283 3820 1.40.53.164.810655 5192 4002.03.166.011771 4786 1.40.53.371.213284 6299

Rated voltage 0.6/1kV 3+1 cores Basic parameter of Power CableNominal cross section mm2Thickness of insulation mmYJV,YJLVApproximate weight of cable kg/km Approximate weight of cable kg/kmThickness of sheath mmApprox. overall diameter of cable mmYJVYJLVInner covering mmThickness of steel tape mmThickness of sheath mmApprox. overall diameter of cable mmYJV62YJLV622.5/1.50.7/0.71.812.4198 143 0.90.21.815.0342 287 4/2.50.7/0.71.813.6262 174 0.90.21.816.2420 332 6/40.7/0.71.814.8343 211 0.90.21.817.4515 382 10/60.7/0.71.817.7506 290 0.90.21.820.3710 495 16/100.7/0.71.819.8724 378 0.90.21.822.4953 607 25/160.9/0.71.823.51083 536 0.90.21.826.11354 807 35/160.9/0.71.825.31371 649 0.90.21.928.11676 954 50/251.0/0.91.928.81852 853 0.90.22.031.62198 1199 70/351.1/0.92.033.52593 1158 1.20.22.238.33378 1944 95/501.1/1.02.237.93506 1522 1.20.52.342.54367 2383 120/701.2/1.12.342.14452 1897 1.20.52.546.95425 2871 150/701.4/1.12.546.95361 2305 1.40.52.651.96430 3373 185/951.6/1.12.651.86732 2851 1.40.52.857.07933 4053 240/1201.7/1.22.958.88740 3670 1.40.53.063.810065 4995 300/1501.8/1.43.164.810850 4504 1.40.53.269.812304 5958 400/1852.0/1.63.371.813718 5628 1.40.53.577.015359 7269

Rated voltage 0.6/1kV 3+2 cores Basic parameter of Power CableNominal cross section mm2Thickness of insulation mmYJV,YJLVApproximate weight of cable kg/km Approximate weight of cable kg/kmThickness of sheath mmApprox. overall diameter of cable mmYJVYJLVInner covering mmThickness of steel tape mmThickness of sheath mmApprox. overall diameter of cable mmYJV62YJLV622.5/1.50.7/0.71.813.3225 161 0.90.21.815.9379 315 4/2.50.7/0.71.814.6300 197 0.90.21.817.2469 366 6/40.7/0.71.816.0398 241 0.90.21.818.6583 426 10/60.7/0.71.819.2584 332 0.90.21.821.8806 554 16/100.7/0.71.821.8844 439 0.90.21.824.41096 691 25/160.9/0.71.825.71262 620 0.90.21.928.51572 930 35/160.9/0.71.827.51557 740 0.90.21.930.31889 1072 50/251.0/0.92.031.62148 998 1.20.22.136.22873 1724 70/351.1/0.92.136.72993 1350 1.20.22.341.53849 2206 95/501.1/1.02.341.54037 1770 1.20.52.446.14976 2709 120/701.2/1.12.446.15186 2223 1.40.52.651.36262 3299 150/701.4/1.12.651.56133 2669 1.40.52.856.77328 3863 185/951.6/1.12.857.17789 3341 1.40.53.062.39106 4658 240/1201.7/1.23.064.510040 4255 1.40.53.269.711521 5736 300/1501.8/1.43.371.312479 5251 1.40.53.476.314074 6845 400/1852.0/1.63.579.015742 6547 1.40.53.785.418358 9163

4.Packing
5.FAQ

1. What kinds of products does your factory manufacture?

1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;

2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;

3)PVC Insulated (Flexible ) Wire ;

4) PVC Insulated and Sheathed (Armoured) Power Cable;

5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;

6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

2. What kind of certifications do you have?

SABS, CE, ISO9001-2000, SGS

3.Which markets do you involve mainly in?

Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

4. Which standards do you comply with when you produce the electrical wires and cables ?

We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

5. What is the min.order quantity ?

It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

6. What is the production capacity per week or per month ?For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.