LYNSB Series Ultrasonic Gas Flow Meter
1.1Introduction
LYNSB- Ultrasonic Gas Flow Meter (hereafter call Ultrasonic Meter) is the key and newly designed product with cutting-edge technology. It can be used in process measuring and custody transfer metering in fields such as gas production of oilfields,energy, and environmental protection. Compared with traditional flowmeters,
Ultrasonic Meter with remarkable performance like low pressure, low velocity, no pressure loss, high accuracy, is becoming the most advanced and quickly developed new flowmeter.
1.2 WorkingTheory
Ultrasonic wave is sonic wave with frequency larger than 20000Hz featured with better directionality, penetration and energy concentration, which makes Ultrasonic Meter the new advance flowmeter.
Ultrasonic Meter uses theory of acoustic transit time, as in Fig 1-1:
Transducer A (Upstream) sends ultrasonic wave that transits in the pipe and will make total reflection when it touch the smooth and high hardness pipe bottom, and then it goes to B(Downstream) transducer that will receive this wave, which make one sonic path. After B receives the wave, it will send another ultrasonic wave that to be received by A. As the medium is actually carrier of sonic wave, when it flows, the transit time will be different with different flow velocity, which will result in flow velocity and flowrate after calculation of mathematical model.
Flow velocity:
Sound velocity:
Flowrate:
Where:
V: Gas flow velocity (m/s)
C: Sound velocity (m/s)
F: Volume of flowing medium (m3/h)
D: Diameter of pipe (m)
: Angle of path to the flow (o)
: Transit time from transducer A to B (s)
: Transit time from transducer B to A (s)
: Sound delay time by circuit, cable and transducer from A to B/ Sound delay time by circuit, cable and transducer from B to A (s)
Features Compared with traditional flowmeter, Ultrasonic Meter has outstanding features:
1) Good performance for measuring low frequency pulsating flow and stable flow;
2) Can be used for tough medium like gas with little vapor or coal tar;
3) High accuracy up to 0.5%, and repeatability less than 0.1%;Wide turndown ratio, up to 1:50;Bi-direction measurement, suitable for small working pressure and low flow velocity;Multi-path measurement can reduce the influence of turbulent flow, and the meter can also work normally when one path broken down;No movable parts inside, near no pressure drop, little maintenance;Self-diagnose function will help to judge, correct and alarm for failures, thus reduce measurement loss;It can output flowrate in standard condition after temperature and pressure compensation.
< >Ultrasonic MeterIn long transportation line of natural gas;In city gas;For well head gas in oilfield;Boiler gas;In large gasification process;Industrial waste gas and torch gas.2. Product Performance2.1 Performance As in Table 2-1.
Table2-1 Product Performance
Accuracy±0.5%, ±1.0%, ±1.5%DiameterDN25mm~DN300mmTurndown Ratio>1:30Medium Gas, liquidOutput SignalPulse, 4~20mACommunication Protocol MODBUS Protocol Ex-proof Common type, Ex-proof typeProtection IP65Ex-proof Grade Exdib II BT4(GYB101058)Working Temp.-40ºC ~+85ºCMax. Overload Flowrate 120%Power SupplyDC 24V (600mA), DC12V(1A)Nominal Pressure 1.6MPa ,2.5MPa,4.0MPa,6.3MPa, 10.0MPa,16MPa,25MPa, 42MPa
Accuracy 0.5%1.0%1.5%Repeatability 0.10.20.3Velocity (m/s)(1.25~25m/s)(1.0~25m/s)(0.8~25 m/s)Size (mm)Flowrange (m3/h)252.2~451.8~451.4~45405.5~1154.5~1153.6~115509~1807~1805.5~1808023~45018~45014~45010035~70028~70023~70015080~160064~160050~1600200140~2830115~283090~2830250220~4420180~4420140~4420300320~6360250~6360200~6360
Notes:Accuracy0.51.01.5Max. ErrorQt≤Q<Qmax±0.5%±1.0%±1.5%Qmin≤Q<Qt±1.0%±2.0%±3.0%RepeatabilityLess than 1/5*Max. errorTurndown ratio1:201:251:30
Note: Qt is the transition flowrate at 3m/s.2.4 Temperature and Pressure Measurement Table 2-4 Accuracy of Pressure and Temperature measurementItemRange Accuracy Temperature -40 ~+85ºC±0.5ºCPressure 0 ~10.0MPa0.25 %FS
2.5 Current Output 4~20mAThe current output is passive and the flowrate in standard condition relative to 20mA can be revised.Range(4~20)mABasic Error0.2% FSTemperature influence±0.01% / ºCThe sample resistance shall be 250~600 Ω
2.6 Positive Frequency OutputPositive frequency output shows gas flowrate in standard condition and its pulse equivalent can be revised.Frequency Range(0~2)kHzBasic Error±0.0005%Temperature influence±0.0001% / ºC
2.7 RS485 OutputRS485 of Ultrasonic Meter use Modbus protocol and RTU mode. Please refer to item 5.5 of user manual, or contact local agency.2.8 Working Condition Table 2-7 Ambient conditionAmbient temperature-25ºC~+55ºCRelative Humidity≤ 80% (25ºC)magnetic field intensity<400A/mMechanical vibrationf<30Hz, amplitude<0.1mMagnetic interferenceAvoid such interferenceSonic noiseAvoid such noise
2.9 Power ConsumptionNormal power consumption is 5W, max. 7W.2.10 Weight Table 2-8 Weight for Ultrasonic MeterSizemm25405080100150200250300WeightKg1721243035497092117
Note: the above weight is for Ultrasonic Meter with PN=1.6mpa