Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment China Med-Pm-Top1800 Portable 6-Parameter Patient Monitor 12.1inch Price

China Med-Pm-Top1800 Portable 6-Parameter Patient Monitor 12.1inch Price

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Classification: Imaging Diagnostic Equipment
Type: Digital EEG/ECG/EKG/EMG/VCG
Certification: CE, ISO13485
Med-Pm-Top1800 portable 6-Parameter Patient Monitor 12.1inch cheap price
MED-PM-TOP1800
Function specification for Med-Pm-Top1800 portable 6-Parameter Patient Monitor 12.1inch cheap price
Patient Monitor:
Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR.
12.1" large-screen color TFT display
7-lead ECG waveforms display ,big font observational interface
Reviewable ECG waveforms, Maximum 72 hours reviewing graphic trendsOptional with thermal recorder

Software specification:


Large font model display: the newly barge font model display application for a full range, long-distance and a real time monitor, observe
Unique complete display: seven lead ECG waveform display and the patient physiological information display, good for doctor to diagnosis and meets all levels of hospital need
Trend display: the dynamic trend display, doctor can directly observe the changes of all parameters, this will help the doctor diagnosis accurately
Bedrail hook,wall hook and rolling stand: we can provide as the clients demand.
Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
Arrhythmia and S-T segment analysis and pacemaker detection
Protection against interference from defibrillation and electrosurgical Unit
Adjustable 3 level audio and visual alarm
Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient
Built-in high-capacity battery, Battery-low indicator, up to 2 hours working time
Unique line back shelf design.



Parameter specification:

ECG

Full lead: I, II, III, AVL, AVR, AVF and V
Gain 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width 0.05Hz-100Hz(3dB)
Heart rate:
Scope: 15 times/minute to 300 times/minutes
Accuracy: ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
Arrhythmia :Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10
seconds kept for each time.
Accuracy: Error rate < 20%
Undetected rate < 20%
Analysis function should be started when using the above two kinds of function.
ST section
Scope: ±0.8mV
Precision : < ±0.05mV

NIBP
Theory Electric oscillator
Cuff gassing time less than 15 seconds
First-time gassing pressure: dynamic state 24kPa (180 mmHg)
Manual selection: 9.3kPa (70 mmHg),13.3kPa (100 mmHg),16.0kPa
(120 mmHg)
18.6kPa (140 mmHg),20.0kPa (150 mmHg),21.3kPa (160 mmHg),
Automatic detection period: 1 minute to 240 minutes
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 min -90min) and 30min(90 min -240min)
Detection scope:
Systolic blood pressure: 4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure 2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure 2.7kPa~31.3kPa (20mmHg~235mmHg)
Detection accuracy
Static pressure: ±3mmHg
Pulse rate: ±2%

Resp
Chest impedance method or concentration of carbon dioxide at end of respiration
Scope of chest impedance method 0 time/minute - 100 minutes/minute
Precision of chest impedance method 1 time/minute
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute (including baby)
Detection precision of respiration rate: ±1 time/minute
Temp
Single/double path
Type: Vascular/surface temperature
Scope: 20°C~50°C
Accuracy ±0.2°C
Invasive blood pressure (selected mating)
Single/double path
Type: direct and continuous detection
Scope: -6.67kPa(-50mmHg)-46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg) 13.33kPa(100mmHg) above ±2%
Frequency response: DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage: 5V (DC)
Accuracy of sensor: ±2%
Isolation voltage: 4 kV