Business Type:
Trading Company
Business Range:
X ray machine, Ultrasound, Vet items, Dental items
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, WesternUnion
Main Markets:
Southeast Asia, Middle East, Africa, Others
OEM/ODM Service
Sample Available

Hospital Equipment, Medical Equipment, Medical Supply manufacturer / supplier in China, offering Ysenmed One-Station Shopping Medical Hospital Equipment, Hospital Ysav200A Built-in Oxygen Air Blender Baby Neonatal Ventilator, Medical Ysvv500 Blood Locator Detector Finder Portable Vein Viewer and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment China Medical Hospital Equipment High Frequency X-ray C-Arm

China Medical Hospital Equipment High Frequency X-ray C-Arm

Get Latest Price
Min. Order / Reference FOB Price
1 Set Contact Supplier
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, WesternUnion
Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: ISO13485
High frequency Mobile Digital C-Arm X Ray YSX-C35D
Main componentsTechnique parameter
IMD X-ray tubeModel:YSX-C35D
Power: 3.5kWPower: 5.0kW
Double focus fixed anode focus: 1.5mm / 0.6mmDouble focus rotational anode focus: 0.3mm / 0.6mm
Anode Heat Capacity: 40kHu X-ray tube sleeve heat capacity: 667kHuAnode Heat Capacity: 200kHu X-ray tube sleeve heat capacity: 800kHu
High Voltage X-ray GeneratorWorking frequency: 40kHz
Image intensifier9"(including 3 fields of view 4.5"/ 6"/9")
Tube voltageFluoroscopy Radiograph: 40kV-110kVFluoroscopy Radiograph: 40kV-120kV
Tube currentFluoroscopy: 0.5-4mA Enhanced Automatic Fluoroscopy: 1mA-8mA Pulse Fluoroscopy: 2pps; 8mA
MAs1mA. S-250mA. S
Fluoroscopy modeManual Fluoroscopy; Semi-Automatic Fluoroscopy; Automatic Fluoroscopy; Enhanced Automatic Fluoroscopy; Pulse Fluoroscopy
Intelligent exposure controlNo matter the object is in the center or on the fringing field of the image intensifier, the images are the same. The exposure dose is reduced.
Iris beam limiting devicewhen not exposure, keep in the state of Iris Beam limiting preview, when exposure, keep blanking cycle track
General radiography40kV-120kV; 1.0mA. S-250mA. Sstep length 1 kV; 1.0mA. S
Digital radiography (digital spot film)40kV-120kV; Max 16mACommon screen film radiography is eliminated. Digital radiography can get better images
C-arm machinery indexC-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven up and down, easy and handy to operate. The machine can maintain balance with up and down of the C arm.
Distance between focus and window>900mm, arc depth>650mm, horizontal moving range: 200mm vertical moving range: 400mm
Tilt angle: ± 12.5° Rotation: ± 180° Corner: 125° (-35° -- +90° )
Laser OrientationLaser positioning function can help to position precisely and reduce exposure times in the operation, reduce unnecessary radiation.
Radiography mode
Image intensifier & Real-time digital image(1.3 million pixel) processing system
(CCD)Digital video cameramillion pixels high-definition, high-speed CCD camera, a 1024 x 1024 matrix, 30 frames per second image acquisition, through real-time adjustment of window width, window level, noise reduction, sharpening and Gain adjustment to ensure high-quality and high-resolution images.
Image resolution indexGrey level: 10 Resolution: 22 lp/cm
Camera virtual rotation designNo X-ray needed, also called digital image rotation, display the right angle when exposure, superior to camera mechanical rotation
Image processing system1. Real time edge enhancement(sharpening)Image sharpening is also called edge enhancement, that is, to make blurry edge of the image clearer
2. Real time adjustment of the window width and window levelObtain images by real-time adjustment of window width, window level, displaying images with different brightness.
3. Real time(static)multiform noise reductionNoise reduction, and improve image clarity
4. Real tim GAIN adjustmentCan amplify image signal, reduce x-ray dose, suitable for patient with super large size.
5. Real tim dynamic brightness compensation and R calibration functionsThrough dynamic logarithmic transformation, linear reduction the system signals and r calibration technology, dark parts of the image can be enhanced and clear rich-layer images can be obtained
6. Image conversing, up-down and right-left rotating, and frame freezing
7. Patient information management, Clinic report and print
8. The Image can be storage as JPG and DICOM 3.0 format, can be linked to hard-disk, USB and DVD and printer, meet the need of sharing the network information, communication and storage in hospital
DisplayDisplay2 17' TFT-LCD display
PrinterPrinter Laser / jet Printer

Main componentsTechnique parameter IMD X-ray tubeModel:YSX-C35DModel:YSX-C50D Power:3.5kWPower:5.0kW Double focus fixed anode focus:1.5mm / 0.6mmDouble focus rotational anode focus: 0.3mm / 0.6mm Anode Heat Capacity:40kHu X-ray tube sleeve heat capacity:667kHuAnode Heat Capacity:200kHu X-ray tube sleeve heat capacity:800kHu High Voltage X-ray GeneratorWorking frequency:40kHz Image intensifier9"(including 3 fields of view 4.5"/ 6"/9") Tube voltageFluoroscopy Radiograph:40kV-110kVFluoroscopy Radiograph:40kV-120kV Tube currentFluoroscopy: 0.5-4mA Enhanced Automatic Fluoroscopy: 1mA-8mA Pulse Fluoroscopy :2pps;8mA mAs1mA.s-250mA.S Fluoroscopy modeManual Fluoroscopy; Semi-Automatic Fluoroscopy;Automatic Fluoroscopy; Enhanced Automatic Fluoroscopy; Pulse Fluoroscopy Intelligent exposure controlNo matter the object is in the center or on the fringing field of the image intensifier, the images are the same. The exposure dose is reduced. Iris beam limiting devicewhen not exposure, keep in the state of Iris Beam limiting preview ,when exposure,keep blanking cycle track General radiography40kV-120kV;1.0mA.s-250mA.sstep length 1 kV;1.0mA.s Digital radiography (digital spot film)40kV-120kV;Max 16mACommon screen film radiography is eliminated. Digital radiography can get better images C-arm machinery indexC-arm stander(with perfect C arm balance system) of ultra-quiet motor-driven up and down, easy and handy to operate. The machine can maintain balance with up and down of the C arm. Distance between focus and window>900mm, arc depth>650mm, horizontal moving range :200mm vertical moving range:400mm Tilt angle :±12.5° rotation :±180°corner:125°(-35°-- +90°) Laser OrientationLaser positioning function can help to position precisely and reduce exposure times in the operation, reduce unnecessary radiation. Radiography mode Image intensifier & Real-time digital image(1.3 million pixel) processing system (CCD)Digital video cameramillion pixels high-definition, high-speed CCD camera, a 1024 x 1024 matrix, 30 frames per second image acquisition, through real-time adjustment of window width, window level, noise reduction, sharpening and Gain adjustment to ensure high-quality and high-resolution images. Image resolution indexGrey level:10 Resolution:22 lp/cm Camera virtual rotation designNo X-ray needed, also called digital image rotation,display the right angle when exposure, superior to camera mechanical rotation Image processing system1.Real time edge enhancement(sharpening)Image sharpening is also called edge enhancement, that is, to make blurry edge of the image clearer 2.Real time adjustment of the window width and window levelObtain images by real-time adjustment of window width,window level, displaying images with different brightness. 3.Real time(static)multiform noise reductionNoise reduction, and improve image clarity 4.Real tim GAIN adjustmentCan amplify image signal, reduce x-ray dose, suitable for patient with super large size. 5.Real tim dynamic brightness compensation and R calibration functionsThrough dynamic logarithmic transformation,linear reduction the system signals and r calibration technology, dark parts of the image can be enhanced and clear rich-layer images can be obtained 6.Image conversing ,up-down and right-left rotating,and frame freezing 7.Patient information management ,Clinic report and print 8.The Image can be storage as JPG and DICOM 3.0 format, can be linked to hard-disk ,USB and DVD and printer,meet the need of sharing the network information ,communication and storage inhospital DisplayDisplay2 17' TFT-LCD display PrinterPrinter Laser / jet Printer Standard configuration1.Combined tube(5.0kW)IMD1 set; 2.Image intensifier (9 inch 3 fields of view)1 set 3.C-arm stander (with full C-arm balance system)1 set; 4.Exported grid1 set 5.Laser positioning1 set; 6.1.3million pixel 1024x1280x10bit camera1 set; 7.Electric adjustable beam limiting device1 set 8.17 inch LCD high resolution screen2 sets 9.Real-time digital imageprocession system (station)1 set; 10.Printer1 set