Fetal Doppler, Fetal Monitor, Color Doppler manufacturer / supplier in China, offering Meditech Fetal Heart Doppler Sonotech Xpress Ce Approved with LCD Display, Meditech Ce Approved Portable ECG Machine Electrocardiograph, Handheld 12-Lead Electrocardiograph, ECG/EKG Machine Ce Approved and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment China Meditech Manufacture MD908 Medical Patient Monitor with Ce &ISO Approved

China Meditech Manufacture MD908 Medical Patient Monitor with Ce &ISO Approved

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $1430.00/ Piece
Local Area: Qingdao, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient/Fetal/Maternal Monitor
Certification: CE, FDA, MSDS, ISO13485
MD908
Meditech MD908 is a compact Multi-parameter Patient Monitor with 8inch color TFT display. It has standard parameters as ECG, NIBP and SPO2, and optional parameters as RESP, 2-TEMP, 2-IBP, ETCO2, Network, Thermal Printer, Pacing Maker.
FEATURES
8.4 "color TFT display
Unique digital SPO technology with excellent measurement and interference-free
Audible and visual alarms with adjustable alarm range
Anti electrosurgical interference and defibrillation
Can be connected with LAN to work with central monitoring system
Powerful data management and storage capacity
Suitable for adult pediatric and neonatal patient
Standard configuration:
ECG
Lead type: 5-lead
INPUT: the RA; LA; RL; LL; V
Sweep Speed: of 12.5 mm / S 25mm / 50mm S / S
the Accuracy: Which IS 1¾1bpm% or Greater 1¾1
Protection: Withstand 4000VAC / 50Hz Voltage Isolation Against Electrosurgical and in at defibrillation
ST Detection: YES Arrhythmia analysis: YES
Alarm: YES audible and visual alarm alarm events recallable

NIBP
Method: Oscillometry
Operation modes: Manual / Automatic / STAT
Measurement unit: mmHg / KPa selectable
Measurement types: Systolic Diastolic Mean
Over-pressure protection: YES
SPO2
Measurement range: 0 -100%
Accuracy: 2digit (70 ~ 100%)
0 ~ 69% unspecified
Optional
RESP 2-TEMP 2-IBP ETCO2 Network Thermal Printer
SPECIFICATIONS
ECG
Lead Mode 5 Leads (RLFNC or RA LA LL RL V)
Lead selection I II III avR avL avF V
Waveform 2 ch
Lead mode 3 Leads (RLF or RA LA LL)
Lead Selection I II III
Waveform 1 ch
Gain '2.5mm / mV' 5.0mm / mV '10mm / mV' 20mm / mV
HR and Alarm
Range
Adult 15-300 bpm
Neo / Ped 15-350 bpm
Accuracy ± 1% or ± 1bpm which great
Resolution 1 bpm
Sensitivity> 200 uV PP
Differential Input Impedance> 5 MΩ
CMRR
Monitor> 105 dB
Operation> 105 dB
Diagnosis> 85 dB
Electrode offset potential ± 300 mV
Leakage Current <10 μA
baseline Recovery <3 s After Defi.
ECG Signal Range ± 8 mV (Vp-p)
Bandwidth
Surgery 1 to 15 Hz
Monitor 0.5 to 35 Hz
Diagnostic 0.05 to 100 Hz
Calibration Signal 1 mV (Vp-p) ± 5% Accuracy
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE VFIB / VTAC COUPLET BIGEMINY TRIGEMINY R ON T VT> 2 PVC TACHY BRADY MISSED BEATS PNP PNC
Alarm Available
Review Available
RESPARATION
Method Impedance between RF (RA -LL)
Differential Input Impedance> 2.5 MΩ
Measuring Impedance Range: 0.3 ~ 5.0Ω
base Line Impedance Range: 0 - 2.5 KΩ
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range Adult 0 ~ 120 rpm
Neo / Ped 0 ~ 150 rpm
Resolution 1 rpm
Accuracy ± 2 rpm
Apean Alarm 10 ~ 40 S
NIBP
Method Oscillometric
Mode Manual Auto STAT
Measuring Interval in AUTO Mode 1 2 3 4 5 10 15 30 60 90 120 180 240 480 Min
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS DIA MEAN
Measuring and Alarm Range Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 to 165 mmHg
Neonatal Mode
SYS 40 to 135 mmHg
DIA 10 to 100 mmHg
MEAN 20 to 110 mmHg
Resolution
Pressure 1 mmHg

Accuracy Pressure
Maximum Mean ± 5 mmHg
Maximum Standard deviation ± 8 mmHg
Overpressure Protection
Adult Mode 297 ± 3 mmHg
Pediatric Mode 240 ± 3 mmHg
Neonatal Mode 147 ± 3 mmHg

Sp02
Measuring the Range 0 to 100%
the Alarm the Range 0 to 100%
Resolution 1%
of The the Accuracy 70% ~ 100% ± 2%
0% ~ 69% Unspecified
Actualization interval The of The the about 1Sec.
of The the Alarm Delay 10 Sec.
Pulse Rate
Measuring and The the Alarm The the Range
0 ~ 254bpm
Resolution 1bpm
The the Accuracy ± 2bpm
The the Alarm Delay 10 Sec.

MASIMO Specification:
The the Range
Saturation, (% Sp02). 1% ~ 100%
Pulse Rate (BMP) 25 ~ 240
the Accuracy
Saturation, (% Sp02 During No Motion Conditions *
Adults 70% -100% ± 2digits
Unspecified% -69% 0
neonates 2digits ± 70% -100%
Saturation, During Motion Conditions **
Adults 3digits ± 70% -100%
0% -69% Unspecified
neonates 3digits ± 70% -100%
Pulse (BPM) During No Motion Condition 25 to 240 ± 3digits
Pulse (bpm) - During Motion Condition 25 to 240 ± 5digits
Resolution
The Average Time by Constant <10 Sec. The Options: EtCO2 the IBP (% SpO2) 1%

TEMPERATURE
Channel 2
Measuring and Alarm Range 0 to 50 ° C
Resolution 0.1 ° C
Accuracy ± 0.1 ° C. Recorder the STANDARD ACCESSORIES: the ECG Cable (Leads. 5) ...... 1Pcs Sp02 Cable (Adult) ..... 1Pcs the TEMP the Probe 1Pcs NIBP Cuff (Adult). ......... 1Pcs NIBP Tube (150cm) ......... 1Pcs Ground Cable .... .......... .. 1Pcs Power Cable .... ............... 1Pcs Cleaning Cloth ............. ... 1Pcs