Business Type:
Manufacturer/Factory
Business Range:
ECG, Patient Monitor, Spirometer, Oximeter, Defibrillator, AED, Ultrasound Scanner, Fetal
Establishment:
2008
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Fetal Doppler, Fetal Monitor, Color Doppler manufacturer / supplier in China, offering Meditech Fetal Heart Doppler Sonotech Xpress Ce Approved with LCD Display, Meditech Ce Approved Portable ECG Machine Electrocardiograph, Handheld 12-Lead Electrocardiograph, ECG/EKG Machine Ce Approved and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment China Meditech Spirometro Da Tavolo Con Sensore Di Flusso Differenziale Ad Alta Precisione

China Meditech Spirometro Da Tavolo Con Sensore Di Flusso Differenziale Ad Alta Precisione

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $80.00/ Piece
Local Area: Qingdao, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Spirometer
Certification: CE, FDA, MSDS, ISO13485
SPIROX PRO
The portable pulmonary function measurement instrument can be used to measure vital capacity (VC), forced vital capacity (FVC), Maximum Ventilator Volume (MVV). Measurement algorithm refers to the ITS, ERS standards of the American Thoracic Society (ATS)Measuring principle
When be normally breathing, the gas passed through the flow sensor. On both sides of the screen of the sensor will produce different pressure. The pressure is detected by the sensor, which is converted to electrical signals. After the signal amplification, AD converter sampling, the pressure is converted to digital signal into the computer system. Through digital signal processing and analyzing technology, computer system reproduces the breathing waves that are displayed on the LCD together with analyzed results. In the end the built-in printer prints out the analysis results.Single use filterSingle use mouth set
PRODUCT FEATURES
The portable pulmonary function measurement instrument can be used to measure:
Vital capacity (VC)
Forced vital capacity (FVC) Maximum Ventilator Volume (MVV).
Measurement algorithm refers to the ITS ERS standards of the American Thoracic Society (ATS)
Measurement of breathing time:
VC time 50 seconds
FVC measuring time 25 seconds
MVV time 12 seconds in favor of the coordination between patients and the device
Adopting pressure-flow sensor sensitive precise easy to launder clean and durable
All parameters can be displayed on large screen(320 x 240)
Built-in memory can store maximum 300 cases of patient measurement results
The instrument can calibrate automatically all English operation more convenient to operate
110mm thermal printer built-in can print out a clear clinical report predicted value measured value
Compact and flexible
SpioSoft PC Software for data transfer (Options)
PRODUCT SPECIFICATIONS
Measurement methods:
Flow velocity detection: Screen type pneumotachograph flow sensor
Capacity detection:flow integration
Measuring range
Capacity range:0L ~ 9L
F low velocity range: 0 ~ 14L / s
Measurement accuracy
Capacity: 0L ~ 1.6L (± 50ml)
6L ~ 9L (± 3%)
Flow rate: 5% or 0.2L / s
Respiratory rate: 4 / 20 ~ / min (± 1 / min)
20 / 60 / min (error: ± 5%)
Measuring time limit and degree
VC: 50s per time, measuring 3 times
FVC: 25s per time, measuring 3 times
MVV:12 seconds per time, measuring 3 times
Display (LCD): 320 * 240 dot-matrix
printer: 110mm thermal printer
Data: 10 integral recordsOther NotePower: A.C. 100~220V 50/60Hz
The type of security: I Class B type
Transport and storage note
Ambient temperature range:-20°C ~ 55°C;
Relative humidity range: ≤ 93%;
Atmosphere pressure range: 500hPa ~ 1060hPa;
Working note
Surrounding temperature range: 10°C ~ +40°C;
Relative humidity range: 30% to 75%;
Atmosphere pressure range: 700hPa ~ 1060hPa;Other NotePower: A.C. 100~220V 50/60Hz
The type of security: I Class B type
Transport and storage note
Ambient temperature range:-20°C ~ 55°C;
Relative humidity range: ≤ 93%;
Atmosphere pressure range: 500hPa ~ 1060hPa;
Working note
Surrounding temperature range: 10°C ~ +40°C;
Relative humidity range: 30% to 75%;
Atmosphere pressure range: 700hPa ~ 1060hPa;
RELATED ACCESSORIES
Standard:
Single use filter.................... 1Pcs
Single use mouth set........... 1Pcs
Nose clip.............................. 1Pcs
Ground Wire ....................... 1Pcs
Power cable .......................... 1Pcs
Cleaning Cloth ...................... 1Pcs