Cross-Road Bridge Structure, Bridge Structure, Cross-Road Structure manufacturer / supplier in China, offering Megatro Overhead Bridge Span Sign Structures, Megatro Flag Poles, Megatro 500kv 5e4 Sz3 Suspension Transmission Tower and so on.

1
    YRS
General Supplier

China Megatro Power Distribution Pole

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $2150.00/ Set
Local Area: Zhuhai, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Usage: Tension Tower, Angle Tower, Terminal Tower, Transposition Tower, Branching Tower
Conductor Circuit: Double Circuit
Certification: ISO
MEGATRO provide every type of 80FT distribution pole, mainly for city power grid and power distribution network. These pole belong to tubular pole, which shall be made of welded tubes, swaged and joined together. It is uniformly tapered in circular in cross-sections. The sections of the steel poles shall be designed such that the butt end of the top section fits on the top end of the second section, the butt end of the second sections fits on the top end of the third sections and so on. The varisou sections shall be fitted together by pressed frication joints. Most of power voltage as 35KV, 66KV, 69KV, 110KV, 115KV, 132KV, 220KV, after fabrication all distribution poles are delivered to the galvanizing facility to be Hot DIP Galvanized. Distribution poles are processed through the facility by Caustic Cleaning, Pickling, and then Fluxing. These strict procedures insure years of maintenance free towers. MEGATRO's distribution poles can accommodate a variety of cross-arm.
Our 80FT distribution pole can be divided nine types again, and mail specification as follows:
TOP DIAMETER: 165-200MM
BOTTOM DIAMETER: 470-555MM
THREE SECTIONS
LENGTH: 24380MM
THICKNESS: 4/5/6MM
ON THE BOTTOM OF POLE, WE ALSO FIXED WITH ANTI-SINK STRAPS. THE POLE TOP MAXIMUM LOADING AS 1275KG, OR baseD ON DESIGN AGAIN
1 ALL STEEL PLATES TO ConFORM TO ASTM A572 GR50 OR ANY EQUIVALENT.
2 ALL WELDS ARE TO ConFORM TO AWS D1.1.
3 ALL SHAR EDGES AND BURRS TO BE REMOVED.
4 ALL TAPER LOCK JOINT LENGTHS ARE NOMINAL U. O. N.
5 ALL STEEL TO BE FULLY HOT DIP GALVANIZED AFTER FABRICATION IN ACCORDANCE WITH ASTM A123.
6 ALL POLES ARE OCTAGonAL HEDECAGON (16 SIDED) OR SIX-SIDES, EIGHT-SIDES, TWELVE-SIDE OR OTHERS.
7 PACKAGE: TO BE DISCUSSED BY BOTH PARTIES
8 TERMS OF PAYMENT: L/C, T/T
9 MINIMUM ORDER: 10 SETS
10 PORT OF LOADING: QINGDAO PORT
11. LEAD TIME: ONE MonTHS AND AS PER CLIENTS
APPLICABLE STANDARD AND CODES
All towers & poles manufactured and design shall be generally in accordance with latest revision of the following standards except where specifically directed otherwise.
General
IEC 60826 - Design criteria of overhead lines
IEC 60652 - Loading tests on overhead line structures
ISO 1459- metallic coatings - Protection against corrosion by Hot Dip Galvanizing
ISO 1461- Hot dip galvanized coatings on fabricated iron and steel articles
ISO 12944 - Paint coatings, corrosion protection, and structural steelwork
ISO 898-1- Mechanical properties of fasteners. Part 1-Bolts, Screws and studs
ISO 630 - Structural Steels - plates, wide flats, bars, sections and profiles
ISO 657 - Hot rolled structural steel plates tolerances on dimensions and shape
ISO 7411 - Hexagon Bolts for high strength structural bolting with large width across flats
ISO 657-5- Hot rolled Structural Steel Sections equal and unequal leg angles
ISO 7452- Hot rolled structural steel plates tolerances on dimensions and shape
BS EN 50341-1 -Overhead electrical lines exceeding AC 45kV -General Requirements
BS 8004 - Code of Practice for Foundations
BS 8110 - Structural use of concrete
ANSI10-97- Design of latticed steel transmission structures
IEC 60050 (151) International Electro-technical Vocabulary
Part 51 Electrical and Magnetic Devices
IEC 60050 (601) Chapter 601: Generation, transmission and distribution of electricity-General
IEC 60050 (601) Chapter 601: Generation, transmission and distribution of electricity-Operation
IEC 60059IEC standard current ratings
Chinese Standard

NoCodeDEscriptION1GB/T2694-2003Power Transmission line Steel tower - Technical requirements for manufacturing2JGJ81-2002Technical specification for welding for steel structure of building3GB9787-88Measuring and allowable tolerance for hot-rolled equal angle4GB709-88Measuring and allowable tolerance for hot-rolled plate and strip5GB/T699-1999Quality Carbon Structural Steel6GB/T1591-1994Low alloy high strength structural Steel7GB700-88Carbon Structural Steel8GB222-84Method of sampling steel for determination of chemical composition and permissible variations9GB/T228-2002Method for Tensile testing of metals10GB/T232-1999Method for Bending test of metals11GB/T5117-1995Carbon Welding Rod12GB/T5118-1995Low Alloy Welding Rod13GB/T8110-1995Welding wires for gas shielding arc welding of carbon and low alloy steels14GB/T10045-2001Carbon steel flux cored electrodes for arc welding15JB/T7949-1999Weld outer dimensions for steel construction16GB50205-2001Test Standard for Acceptance of Steel Structure17GB/T470-1997Zinc Ingot18GB3098.1-2000Mechanical properties of fasteners-Part 1:Bolts, screws and studs19GB3098.2-2000Mechanical properties of fasteners-Part2: Nuts, and thread20GB3098.3-2000Mechanical properties of fasteners-Part3: Fastening screw21GB/T5780-2000Helical Bolts Grade C22GB/T41-2000Helical Nuts Grade C23GB/T90-2002Flat Washer Grade C24GB/T13912-2002metal Coating, Technical Requirement and Test Method for Hot-dip galvanized metal Parts




American Standards:

StandardDescriptionASTM A6/A6MStandard specification for general requirements for rolled structural steel bars, plates, and sheet piling.ASTM - 6- General Requirements for delivery of Rolled Steel Plates, Shapes, sheet Piling Bars for structural usedASTM A36/A36-M-97aStandard specification for Carbon structural steelASTM A123 / A123M-02Standard specification for Zinc (Hot-Dip Galvanized) Coatings on iron and steel productsASTM A143 / A143M-03Standard Practise for Safeguarding Against Embitterment of Hot-Dip Galvanized Structural Steel Products and Procedure for Detecting EmbittermentASTM A153/ A153M-05Standard specification for zinc coating (Hot-Dip) on iron and steel hardwareASTM A - 194 -Grade for boltASTM A239Standard practice for locating the thinnest spot in a zinc (Galvanized) Coating on Iron or Steel ArticlesASTM A242Standard specification for High-Strength Low-Alloy Structural steelASTM A307Standard Specification for Carbon Steel Bolts and Studs, 60000 PSI Tensile strengthASTM A370-06Standard Test Methods and Definitions for Mechanical Testing of Steel ProductsASTM A325Standard Specification for structural bolts, steel, Heat treated 120/105 ksi minimum tensile strengthASTM A-325 or A-354 - Galvanized hexagonal head of connection boltASTM A325-97Standard Specification for High-strength Bolts for structural steel JointsASTM A384 / A384M-02Standard Practise for Safeguarding Against Warpage and Distortion During Hot-Dip Galvanizing of Steel Assemblies.ASTM A394-93Standard Specification for steel Transmission Tower, Bolts, Zinc Coated and BareASTMA - 563- Class and size of nutsASTMA - 572 - Chemical composition of steelASTM A572/A572-97cStandard specification for High-Strength Low-Alloy Columbium-Vanadium Structural steel ASTMA - 615 -The anchor bolt materialASTM A673 / A673M-07Standard Specification for Sampling Procedure for Impact Testing of Structural SteelASTM B201Standard practice for testing Chromatic coating on Zinc and Cadmium surfacesASTM E94-93Standard Guide for Radiographic TestingASTM E 709-95Standard Guide for Magnetic Particle ExaminationASCE Manual 72- Load testing a simple structureASCE 10-97Standard Design of latticed steel transmission structuresAWS D1.1American Welding Society D1,1/D1,1M structural Welding code- SteelANSI B-182-2Bolts, nuts and washers dimensions


DIN VDE 0101 - Isokeraunic Level
VDE 0201- Climatic and environmentalconditions
CVDE 0210- Minimum safety factors under simultaneous working loads
ISO R898 Mechanical Properties of Fasteners
BS EN ISO 1461:1991 - High dip galvanized coatings on fabricated iron and steel articles. Specifications and standards
A) BS 5950: Welding Terms And Symbols
B) BS 729: Hot - Dip Galvanised Coating On Iron And Steel Articles
C) BS 2901: Filler Rods And Wires For Gas Shielded Arc Welding: Part 1 Ferritic Steels
D) BS 3692: ISO Metric Precision Hexagon Bolts, Screws And Nuts
E) BS 4360: Weldable Structural Steel
F ) BS 5135: metal - Arc Welding Of Carbon And Carbon Manganese Steel
G) BS 5950: Part 1: Code Of Practice For Loading Latticed Tower & Masts
Part 2: Guide To The Background And Use Of Part 1"Code OF Practice For Loading"
Part 3: Strength Assessment of Members
H) DD 133 (1986): Code Of Practice For Loading Latticed Tower & Masts
I) BS 4592 (1987): Part 2: Specification For Expanded metal Grating Panels
J) BS 4592 (1977): Code Of Practice For Protective Coating Of Iron And Steel Structure Against Corrosion
K) BS 4190: Bracing & Flanged Bolts
L) BS 4190: Rolled Steel sections, Flats & Plates

Moreover, we also can design tower foundation according to below standard:
BS 8004 - Code of Practice for Foundations
BS 8110 - Structural use of concrete
BS 4449 - Carbon steel bars for the reinforcement of concrete