Circuit Breaker, Vacuum Circuit Breaker, Indoor Vacuum Circuit Breaker manufacturer / supplier in China, offering Vb4-11kv/630A-25ka Draw-out Type Indoor Vacuum Circuit Breaker (VCB), 36kv Gas Insulated Indoor 50/60Hz Ring Main Unit, 24kv Sf6 Gas Insulated Indoor 630A Ring Main Unit and so on.

1
    YRS
General Supplier

China Metal Clad Switchgear

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $3000.00/ Piece
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, Small-amountpayment
Type: Switch Cabinet
Transport Package: Seaworthy Wooden Case
Specification: metal clad

KYN28 indoor metal-clad withdrawable switchgear(hereinafter short as switchgear)is a complete

power distribution device for 3.6~24kV,3-phase AC 50Hz,single-bus and single-bus sectionalized

system. It is mainly used for power transmission of middle/small generators in power plants;

power receiving, transmission for substations in power distribution and power system of

factories, mines and enterprises, and starting of large high-voltage motor, etc.,so as to control,

protect and monitor the system. The switchgear meets IEC298,GB3906-91.In addition to be

used with domestic VS1 vacuum circuit breaker, it can also be used with VD4 from ABB,3AH5

from Siemens domestic ZN65A,and VB2 from GE, etc.,it is truly a power distribution device

with good performance.

In order to meet the requirement for wall mounting and front-end maintenance, the switchgear is

equipped with a special current transformer, so that the operator can maintain and inspect it in

front of the cubicle.

a) Air temperature: Maximum temperature: +40ºC; Minimum temperature:-15ºC

b) Humidity: Monthly average humidity 95%; Daily average humidity 90% .

c) Altitude above sea level: Maximum installation altitude: 1000M.

d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

e) No frequent violent shake



Notice:

when the rated current is more than 1600A, cubicle width shall de 1000 mm, and cubicle height

will be 1660mm and for schema of rear overhead line in.

1)Width of cabinet:650mm(compound insulation)or 800mm(air insulation) at current<1250A;

2)Width of cabinet:1000mm at current>1250A;

3)Depth of cabinet:1400mm,at cabinet width of 650mm(compoud insulation)when employing the

configuration of incoming and outgoing cables;

4)Depth of cabinet:1500mm,at cabinet width of 6800mm(air insulation)when employing the

configuration of incoming and outgoing cables;

5)Depth of cabinet:1600mm,when employing the configuration of rear overhead incoming and

outgoing cables.

1) compartment

busbar compartment; circuit breaker compartment; cable compartment; low-voltage compartment.

1 - main device: circuit breaker, contactor,

2 - current transformers,

3 - earthing switch,

4 - voltage transformers,

5 - support-bushing insulators,

6 - bushing insulators

7 - surge arresters,

8 - support insulators (reactance),

9 - main busbars.

10 - connecting (distribution) busbars,

11 - earth-fault current transformer,

12 - earthing conductor,

13 - metal movable particions,

14 - cable ducts (optionally),

15 - vent flaps,



Transportation and Storage

The switch cabinet can be transported by fork truck if guaranteed to be fixed on the bottom plate, and

by handling or removing the entire entity if not fixed on bottom plate, but any case it should be

transported vertically, no allowance for inversion in order not to damage the internal components.

The switch cabinet(even for that with outer package) should not be exposed outside for storage for a

long time. The switch cabinet that needs the long-term storage should be put in the dry and ventilate

indoor warehouse. The period of validity of outer package of switch cabinet is normally no more than 1

year.

Maintenance

Free of maintenance for 3 years under the normal conditions.

There is no need of maintenance and any lubrication for the single-spring and dual-spring operation

mechanism of load switch.

The relay protection device should be checked by the requirement of the manufacturer before put into

the running.

The maintenance periodicity for ring main unit is normally one time every year.

Maintenance by the below requirement:

Fasten all the electrical connectors(main bus bar, switch, cable, measuring meter)required by

Installation and Operation Instruction.

Clean all the parts by dust collector(main switch, auxiliary switch, tripping mechanism, motor etc.) and

check the appearance.

Have a switching on/off operation for all switches including earth switch.

Turn on auxiliary control electric source not giving the remote control signal to have a electrical order

operation.

Clean the busbar cubicle and cable cubicle.

Order

Complete-set Product:

The below documents are attached with the switch panel when out of factory;

Qualification Certificate of Product;

Installation and Operation Instruction;

Packing List;

Engineering Design document of Product;

Accessory of switch panel :

one operating handle of load switch attached with each complete set;

The customer should offer the following information for order:

Wiring diagram of Main circuit Loop and Special Technical Requirement;

Installation Arrangement Plan of switch panel;

Specification of component inside switch panel and the schematic diagram of auxiliary loop and

control loop diagram.

Other written documents specially required.