Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Diesel Generator, Alternator, Lighting Tower, Engine
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Surgical Face Mask, 3ply Mask, N95 Anti Virus manufacturer / supplier in China, offering FDA Approved Disposable 3ply 3 Ply Non Woven Breathing Medical Surgical Protection Anti Corona Virus Coronavirus Face Masks, High Quality FDA Approved Cheap Disposable Protective Breathable 3 Layer Mask, Ce FDA Ffp2 Ffp3 Anti Corona Virus Best Buy Disposable Medical Surgical N95 Face Mask Manufacturer Supplier for USA and so on.

1
    YRS
General Supplier

China Mobile Lighting Tower Genset with Wheels

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $3000.00/ Piece
Local Area: Ningde, Fujian, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke

Light Tower Genset Specification data:

Model XYB6700TXYB6700TLT-10.8KWLT-10.8KWLT-12.8KWLT-12.8KWLight & Tower Height of Mast (M)4.5M4.5M8M8M8M8MType of Mast Stainless stee,Manual mast Rotation of Mast 360 degree360 degree360 degree360 degree360 degree360 degreeTotal power of lamps 4*1000W4*1000W4*1000W4*1000W4*1000W4*1000WType of lamps Halogen lamp metal halide lamp Halogen lamp metal halide lampHalogen lamp metal halide lamp Luminous Flux (lm) 4*50004*85004*50004*85004*50004*8500Lifetime of lamp(h)200030002000300020003000Windproof Ability≤6≤6≤8≤8≤8≤8TireTire Diameter(mm) :200mmTire Model:185R14LTGeneratorRated Power 5KW5KW10.8KW10.8KW12.8KW12.8KWStandby Power 5.5KW5.5KW11.9KW11.9KW14.1KW14.1KWPhase & Voltage Signle phase,230V Signle phase,230V Signle phase,230V Signle phase,230V Signle phase,230V Signle phase,230V Frequency 50HZ50HZ50HZ50HZ50HZ50HZSpeed 3000RPM3000RPM1500RPM1500RPM1500RPM1500RPMStart method Electric starting Electric starting Electric startingElectric starting Electric starting Electric starting Engine model and power 186FA/5.5KW186FA/5.5KW480D/13KW480D/13KWSL2100ABD/16KWSL2100ABD/16KWType of engine single-cylinder, Vertical in-line,4-stroke air-cooled diesel engine Four-cylinder, Vertical in-line,4-stroke water-cooled diesel engine Two-cylinder, Vertical in-line,4-stroke water-cooled diesel engine Fuel tank capacity 16L16L65L65L65L65LPrime fuel consumption1.5L/h1.5L/h3.5L/h3.5L/h5L/h5L/hCooling method lAir cooled Air cooledWater-cooledWater-cooledWater-cooledWater-cooledAlternator model and power SY-5KWSY-5KWLSG164C/10.8KWLSG164C/10.8KWLSG164D/12.8KWLSG164C/12.8KWPrice including tax(RMB) 9300 (Halogen lamp 10500 (metal halide lamp 21730(Halogen lamp 23000(metal halide lamp 20928(Halogen lamp22188(metal halide lamp

Engine Feature1.Diesel, heavy-duty, four stroke, water cooled and direct injection fuel system 2.24/12V D.C starter and charger alternator3.Industrial capacity exhaust silencer supplied loose with flexible section4.Engine driven cooling fan with protection guard 5.Steel wire braided fuel lines, vent and rain fittings 6.Set mounted acid battery installed with leads and terminals Alternator Feature 1.Brushless self excited, single bearing, 4 poles2.Class H insulation3.IP21/23 protection standard 4.Self-exciting and self-regulating 5.Automatic voltage regulator (AVR)Control System: 1. Protection: Automatic start/stop, load transfer and alarming of generator;2. Three channel analog inputs, may joint with Resistive-type temperature/ pressure/ fuel level3. sensors, Several temperature and pressure sensors can be used directly (ie. VDO, DATCON, CUMMINS), also may select "user defined" sensor via entering 8 point curves; 4. Display of generator cumulated electric energy; 5. Security password-protected programming levels.6. Several crank success conditions are optional;7. Power supply range is wide, accommodating to different starting battery voltage environments;8. All parameters use digital modulation, abandoning analog modulation using conventional electronic potentiometer, reliability and stability are increased;9. Built-in watch dog can never be dead halt, ensuring smooth program execution;


STANDARD CONFIGURATION
----------------------------------------------------------------------------------------------------------------------------------------------
√ High-efficiency light fixtures provide uniform light pattern
√ Durable fixtures resist shock and last longer
√ Unique lamp design increases filament life and keeps maximum light on the job longer, increasing productivity while saving time and money
√ Rotating tower allows 360-degree rotation, reducing the need to frequently move the light tower trailer
√ Compact design with removable tow bar allows efficient transport and storage
√ Lockable, weather-resistant, steel cabinet protects components from the elements
√ One outrigger and four leveling jacks provide stability
√ Control panel features running hour meter, receptacles for powering external equipment, and circuit breakers for on/off functionality and protection
√ Automatic engine shutdown system protects engine from damage due to low oil pressure and high coolant temperature
√ Exclusive hinged top panel provides unimpeded access to engine, generator and electrical components
√ Fuel capacity of 30 gallons provides extended run times of 60 to 70 hours between refueling, depending on environmental influences
√ Translucent polyethylene fuel tank provides instant view of fuel level, eliminating the need for a fuel gauge
√ 6,000 Watts of lights from 4 x 1500 Watt metal Halide Lamps
√ Reliable Kubota engine and 6kW rated power generator
√ Quiet 71dBA sound levels at 7m away
√ Durable 9m galvanized hydraulic mast
√ 359° non-continuous tower rotation and retractable mast cable
√ Standard engine protection includes high water temperature and low oil shutdowns
PRP: Prime power is available for an unlimited number of annual operating hours in variable
Load applications, in accordance with ISO8528-1.A 10% overload capability is available for a period of 1 hour within 12-hours period of operation
ESP: The Standby power rating is applicable for supplying emergency power in variable load applications for up to 200 hours per year in accordance with ISO8528-1. Overload is not allowed