Business Type:
Manufacturer/Factory
Establishment:
2016
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Multi-Jet Dry Type Water Meter, Water Meter, Dry Dial Water Meter Meter manufacturer / supplier in China, offering Multi Jet Dry Type Water Meter (LXSG-15E-50E), Class C Volumetric Plastic Water Meter, Accuracy R160, Class C Good Quality Volumetric Water Meter Plastic Body Cheap Water Meter Price and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Meter for Liquid & Gas Water Meter China Multi Jet Brass Body Water Meter R80 R100

China Multi Jet Brass Body Water Meter R80 R100

Get Latest Price
Min. Order / Reference FOB Price
500 Piece US $11.98/ Piece
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Install: Horizontal
Medium Temperature: Cold Water
Level Measurement: Class B/ R80/ R100

Multi jet, Dry-dial

Material body: Brass.

Sizes: DN15 to 20mm, (1/2" - 3/4"), Available for cold water (40°C), hot water(90°C)

Accuracy: Class B/ R80/ R100

Universal use. Easy for interchange & maintenance
MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-1996) Standard

Meter size
Dia
DN
(mm)ClassQs
Overload
FlowQp
Nominal
FlowQt
Transitional
FlowQmin
Min
FlowMin
Reading
LecturaMax
Reading
Lecturam3/hL/hm315A31.5150600.000199999B1203020A52.52501000.000199999B20050


MAIN TECHNICAL DATA According to ISO4064 (GB/T778.1-2007) Standard

DN
SIZEMm
Inch15
1/2"20
3/4"Q4(m³/h) 3.1255Q3(m³/h)2.54R80Q2(L/h)5080Q1(L/h)31.2550R100Q2(L/h)4064Q1(L/h)2540Min reading(m³)0.000050.00005Max reading(m³)99,99999,999Max pressure(MAP)1616Max loss(ΔP)6363Max temperatureT50T50Pulse output optionVmax=24V, Imax=100mA, Pmax=2W


INDICATING ERROR

At low zone is ±5% from minimum flow rate (qmin) to transitional flow rate (qt) exclusive boundary

At high zone is ±2% from transitional flow rate (qt) to overload flow rate (qs)

DIMENSIONS AND WEIGHT

Meter size
Dia
DN
(mm)LengthWidthHeight

Connrcting Thread

D

Weight

Kg

mm1516580100G3/4B1.12019083105G 1B1.4

WORKING CONDITION

Water temperature:≤40ºC for cold water meter

Water temperature:≤90ºC for hot water meter

Working pressure:≤1.6Mpa