My-C007 Portable Patient Monitor with Low Price
Description:
Standard configuration: ECG, HR, PR, SpO2, OxyCRG diagram, ST analysis, Arrhythmia analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation and lead-acid battery, remote control.
Optional configuration:
Wireless networking function to patient monitor;
Inside placed thermal-sensitive built-in printer;
IBP function (Include 1 pressure sensor and 1 adaptable cable);
ETCO2 function module(Respironics-main stream/side stream)-plug&play;
Cardiac Output
Wall Mount for patient monitor;
Trolly for patient monitor;
12 volts Power supply for ambulance
Accessories for Standard configuration:
1 remote controller1 set of ECG cable10 PCS of ECG electrode1 set of NIBP extend cable1 set of NIBP adult or pediatric or neonate cuff1 set of RESP nasal cavity pipe1 set of TEMP surface probe1 set of TEMP cavity probe1 set of integrated adult or pediatric or neonate SpO2 sensor1 set of power supply cable
E CGInput: 5 wires ECG cable Lead section: I, II, III/ AVR, aVL, aVF/ V Gain(mm/mV): 1/4, 1/2, 1, 2, 4Sweep speed(mm/sec): 6.25, 12.5, 25, 50 Heart rate range: 15-300 BPMHeart rate accuracy: ± 1 %ST segment deviation analysis
NIBP (Non-invasive blood pressure) ()
Measurement type: Adult, pediatric, neonatal Measurement range: Systolic 4.0 - 37.0 kPa Diastolic 1.3 - 33.0 kPa Mean 2.6 - 35.0 kPaAccuracy: ± 0.4 kPa or 5 %Resolution: 0.1 kPaProtection: Over pressure
Tourniquet function
Temperature (surface and rectal)Measurement range: 25.0 - 45.0 CAccuracy: ± 0.1 CResolution: 0.1 Cresponse time: ≤ 3 min.
Respiration Rate(RA-LL, RA-LA, LL-LA selectable impedance and nasal cavity) Measurement range: 0 - 120 BPMAccuracy: ± 1 BPM or 5 %Resolution: 1 BPM
Pulse RateSPO2 measurement range: 0 - 100 %Resolution: 1 %Pulse measurement range: 30- 250BPMAccuracy: ± 2 %Resolution: 1 BPM
IBP(Invasive blood pressure) (Option)Measurement range: -1.3~40kPa (-10~300mmHg) Channel: 4 channelTransducer sensitivity: 5MV/V/mmHg Unit display: KPa or mmHg selectable
ETCO2 (main/side stream type) (Option) - Plug&PlayMeasurement range: 0- 150 mmHg 0 -19.7% 0 - 20kpa
(Barometric pressure supplied by Host)Accuracy: 0- 40 mmHg ± 2mmHg
41-70 mmHg ± 5% of reading
71-100mmHg± 8% of reading
101-150mmHg± 10% of reading
Above 80 breath per minute± 12% of reading
*NOTE: Gas temperature at 25 CSample rate: 50ml/minResponse time: < 3 seconds - includes transport time and rise time
Cardiac Output (Option)
Meathod: Thermodilution
Measurement range: CO: 0.1-20.0 L/min
TB: 23-43 C TI: 0 - 27 C Resolution: CO: 0.1 L/min
TI: 0.1C TB: 0.1C
Accuracy: CO: ± 0.2 L/min or ± 5%
TB: ± 0.2 C TI: ± 0.2CParameter output:
Cardiac output Hemodynamics calculation
Power requirements Input: 100~240 V AC, 50/60Hz Consumption: ≤ 80VA Environment Operation Storage Temperature 0.5 - 40 C -20 - 50 C Relative humidity ≤ 80%
Safety standard: IEC 60601-1
Quality System: ISO13485: 2003