Hybrid Solar Inverter, Solar Inverter, on-Grid Inverter manufacturer / supplier in China, offering 3kw/3.2kw/5.5kw on/off-Grid Pure Sine Wave Solar Power Inverters with Energy Storage System, 50A Solar Controller Module Traffic Lights AC to DC Solar DC Power System, Remote Monitoring, 2000W/3000W 48VDC off-Grid Solar Power System for Telecom Tower and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Supply & Distribution UPS China N+X Redundant Design Online UPS Gp9335c Series 120--800kVA

China N+X Redundant Design Online UPS Gp9335c Series 120--800kVA

Get Latest Price
Min. Order / Reference FOB Price
10 Pieces Contact Supplier
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Brand: Sorotec
Phase: Three Phase
Type: On-line
Application: Communication
N+X Redundant Design online UPS GP9335C Series 120--800KVA
Key Features
0.9 output power factor,
UP to 6 units in parallel
6-inch extra large LCD that display 12 language( English/Russian/Spanish/French^)
The efficiency of the machine is more than 94%, and reach 98% in ECO mode.
6th generation DSP control
Intelligent battery management
Layered independently-sealed ventilation channel and redundant fan, embedded make it highly efficient to dissipate heat.
Extra strong capability to withstand output overload and short circuit, ensuring the system stability and system safety under extreme conditions
Extra wide input voltage and frequency range make it adapt to severe power grid environment
Standard input/output filter improves the system EMC performance
Intelligent battery management maintains battery automatically to prolong the battery life
Applications
Mainly used in large IDC rooms, bank/securities settlement center, communication network management center, semiconductor product lines and large automation production and its control system. According to the special needs of users was improved, and used in large sports venues, conference room, theater and highway and railway tunnels metal halide lamp lighting system.
Technical Specifications of Three Phase UPS GP9335C 120-800kVA

ModelGP9335CRectifier Type6p12p6p12p6p12p6p12p6p12pRated Nominal120KVA/108KW160KVA/144KVA200KVA/180KW300KVA/270KW400KVA/36WRated input voltage380/400/415VAC 3-phase 4-wireRated frequency50/60HZInput parametersInput voltage range±25%Input frequency range45Hz~65HzInput soft start function0-100%5-300settableInput power factor>0.98(If harmonic filter is added)Input harmonic current (THDi)<4.5%(If harmonic filter is added)BypassBypass voltage range-20%~+15%Bypass frequency range50/60HZ±10%Output parametersInverter output voltage380/400/415VAC 3-phase 4-wireVoltage stability±1%(Steady status),±3%(Transient status)Frequency50/60HzMains power synchronization window±5%Actually measured frequency accuracy (internal clock)50/60Hz±0.01HzOutput power factor0.9(Output 90kW per 100kVA)Transient response time<5msInverter overload capabilityAt 0.9 power factor, 110% for 1 hour, 125% for 10 minutes and 150% for 60s
Short circuit current from inverter3ph 1.5ln for 5seconds,1ph 2.9ln for 5secondsMaximum Bypasscapability1000% for 100ms
Phase shift
characteristicWith 100% balanced load<1°With 100% imbalance load<1°
Total harmonic
Distortion(THDv)100% linear load<1%100% non-linear load<3%System efficiency (full load)Up to 94% (inverter efficiency is up to 98%)Rectifier output parametersCharger output voltage stability1%DC ripple voltage≤1%Operating environmentOperating temperature range0~40 ºCStorage temperature-25~70ºC(Without battery)Relative humidity0~95%No condensationMaximum operating height≤Elevation 1000m, for elevation above 1000m, derate by 1% for every increase of 100mNoise (1m)58-68dBProtection levelIP20StandardSafety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A Design and Test IEC62040-3Physical parametersWeight (kg)980142012001750135020001600220021002750Width(mm)900125012501640125016401640228022802280Depth (mm)855855855855855855855855855855Height (mm)1900190019001900190019001900190019001900


APPLICATION OF OUR PRODUCT


1. Living house and home building.
2. Office building, factory and warehouse.
3. Shopping mall, stadium and so on.
4. Power station, field operation and some huge engineer construction.
5. suitable for various home appliance, Office equipment,Journeys, Camping, Tents, Boat Trip.

COMPANY SHOW


Introduction of Company
Shenzhen SORO Electronics Co., Ltd is a professional UPS and inverter manufacturer in the field of power electronics for 13 years. We have two large production UPS sites, Zhejiang and Shenzhen. We have own our SMT department. SORO UPS has been a leading enterprise in the UPS industry in China.
Since established, The company has carried out three strategies: operation innovation strategy, people-oriented strategy , technical guidance strategy, and implemented strict scientific management with full-fledged quality management system. The company invests 10% of its annual revenue in researching and development every year. We had international advanced equipments for developing , testing and producing. SORO UPS invited the best technical elites at home, meanwhile, the company established perfect cooperation relationship with domestic scientific research units and academies, to strive for making products that reach advanced world standards.

WHY CHOOSE US ?


1, QC Control
The company ranks first in passing the ISO9001 international quality system certification.We established a complete quality system ranging from material source, process, assembling to testing. Most of our products have been certified to meet international safety standards, such as CE (LVD/EMC), CUL,FCC.
2, Best Partner
We have co-operative partner throughout the world including USA, Europe, South America, South Africa, Middle Eastern, India, Turkey, Pakistan, Iran and so on .We offer wide range quality products either from our own standard range or customer-made to your specifications. SORO is becoming the most growthful China UPS supplier all over the world.

FAQ


1. How to choose suitable inverter?

If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave power inverter.

For example: fans, precision instruments, air conditioner, fridge, coffee machine, computer, and so on.

Modified wave can be started with some inductive loads, but effect for load using life,because capacitive loads and inductive loads need high quality power
.......................................................................................................................................................................
2. How do I choose the size of the inverter?

Different types of load demand for power are different. You can view the load power values to determine the
size of the power inverter.

Notice:

Resistive load: you can choose the same power as the load.

Capacitive loads: according to the load, you can choose 2-5 times power.

Inductive loads: according to the load, you can choose 4-7 times power.
.......................................................................................................................................................................

3. How connection between batteries and an power inverter?

We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the battery terminal voltage, this inverter will appear under voltage alarm conditions
.......................................................................................................................................................................

4. How to calculate the load of working hours requires configuration of the battery size?

We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss,so this is only a reference value:

Work hours = battery capacity * battery voltage * 0.8/load power (H= AH*V*0.8/W)
.......................................................................................................................................................................