Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Home Inverter, Inverter, Power Inverter manufacturer / supplier in China, offering Pure Sine Wave Inverter Home Inverter Power Inverter with UPS Function for TV, Light, AC, Fan, Bulb and Fridge Use, 220V 230V 240V Digital LCD Online UPS System 1k - 3kVA for Home and Office Use, High Frequency Online UPS Power 6kVA - 10kVA with Three Level Inverter Tech and 94% Efficiency and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Supply & Distribution UPS China OEM ODM Double Conversion Online UPS Power 10kVA - 80kVA

China OEM ODM Double Conversion Online UPS Power 10kVA - 80kVA

Get Latest Price
Min. Order / Reference FOB Price
10 Piece Contact Supplier
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Brand: Upsen or OEM
Phase: Three Phase
Type: On-line
Protection: Short Circuit
online UPS Queen Star Series 10K-80KVA (3ph in/3ph out)
Key FeaturesTrue double-conversion.DSP technology guarantees high performance.Output power factor 0.8.Active power factor correction in all phases.50Hz/60Hz frequency converter mode.Accepts dual-mains inputs.Generator compatible.SNMP+USB+RS-232 multiple communications.3-stage extendable charging design for optimized battery performance.Adjustable battery numbers.Maintenance bypass available.Optional N+X parallel redundancy.Technical Specification

Model33Q10KL33Q 20KL33Q 30KL33Q 40KL33Q 60KL33Q 80KLCommentsInputInput voltageRated voltage380VAC/220VAC380VAC Phasethree phase with ground Turn on voltage range(120±5~274±5)VAC(207±9~475±9)VAC Bypass voltage range(60±5~300±5)VAC(105±9~518±9)VACCould be adjusted by software.Bypass
low loss60VAC~220VAC(default 60VAC)105VAC~380VAC
(default 105VAC) Bypass low comebackLow loss +5VACLow loss +17VAC Bypass high loss220VAC~300VAC(default 300VAC)380VAC~475VAC
(default 475VAC) Bypass high comebackHigh loss -5VACHigh loss -17VAC Line low loss
/comeback(120±5) VAC /(140±5) VAC(207±9) VAC /(242±9)VACload≤50%(140±5) VAC /(160±5) VAC(242±9) VAC /(276±9)VAC50%<load ≤90%(160±5) VAC /(175±5) VAC(276±9) VAC /(302±9)VACload>90%Line high loss/comeback(275±5)VAC/(260±5)VAC(475±9)VAC/(449±9)VAC Input frequencyRated frequency50Hz Frequency
low loss(40~49) ±0.2Hz(default:46Hz)Could be adjusted by software.Frequency
low comebackFrequency low loss +0.5HzFrequency
high loss(51~60)±0.2Hz(default:54Hz)Frequency high comebackFrequency high loss -0.5HzInput power factorInput power factor> 0.9933Q 10-40KL:220VAC,full R load
33Q 60-80KL: 380VAC,full R loadGeneratorSupport generator inputGenerator rating≥2*UPS ratingInput currentRated current14A28A42A67A80A105A Input THDI<= 10% Output protectionRating protection32A
Breaker50A
Breaker60A
Breaker80A
Breaker100A
Breaker125A
Breaker Output powerVA/watt10KVA/8KW20KVA/16KW30KVA/24KW40KVA/32KW60KVA/
48KW80KVA/
64KW Rated voltage220VAC380VACSine waveVoltage range200/208/220/230/240VAC345/359/380/397/415 VAC33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC/200VAC.
33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC/359VAC.Voltage regulation±1% Voltage distortion≤5%≤10%Full RCD load≤3%Full R loadDC offset≤200mV Transient response≤9%R load 0%~100%~0%≤6%R load 20%~100%~20%Transient recovery≤60ms voltage recovery to 90%Full RCD loadBypass output
before turn-onYES Crest ration3:1 Output frequency rangeNormal mode1,Same as input frequency(46Hz~54Hz)
2,50Hz(Input frequency>54Hz or Input frequency<46Hz) Battery mode(50±0.1) Hz Slew rate1 Hz/Sec EfficiencyNormal mode> 93%> 90% Battery mode> 90%> 90% OverloadNormal mode
/battery modeOverload warning only105%±5%≤load1min,then transfer to bypass and alarm.105%±5%30S,then transfer to bypass and alarm.125%±5%300mS, then transfer to bypass and alarm.load>150%±5%Automatically retransferYES Short protectionNormal/
battery modeYES Transfer timeNormal to battery mode0mS Battery to normal mode0mS Normal to bypass mode<4mS0mS Bypass to normal mode<4mS0mS Battery and chargerBatteryRated voltage192VDC240VDC192VDC*2192VDC*2480VDC Type/RatingBattery quantity162016*216*240 Backup timeProtectionLow alarm voltage /comebackvoltage(180.8V±4V)/ (188.8V±4V)(226V±4V)/ (236V±4V)(180.8V±4V)/ (188.8V±4V)(226V±4V)/ (236V±4V)(452V±4V)/ (472V±4V)33Q 30KL use twoShutdown voltage/ comeback voltage160V±4V/168V±4V(200V±4V)/ (210V±4V)160V±4V/
168V±4V(200V±4V)/ (210V±4V)(400V±4V)/ (420V±4V) DC protectionOvercharge protection/ comeback voltage(249.6V±4V)/
(216V±4V)(312V±4V) (270V±4V)(249.6V±4V)/ (216V±4V)(312V±4V) (270V±4V)(624V±4V) (540V±4V) Leakage current< 500uA Over discharge protection14.5h Could be set by softwareBattery testBattery weakYES Battery faultYES ChargerOutput voltage(219.2±3)VDC(277±3)VDC(219.2±3)VDC(277±3)VDC(554±3)VDC Charge timeDepends on the external battery capacity Charge current7.5A6A5A4A10A InterfaceAlarm silenceYES DC power
turn-onYES Automatically retransferYES Audio alarmBattery modeBeep/4s Battery low/
charger faultBeep/1s UPS faultContinue beep OverloadBeep/1s Bypass modeBeep/2Min L/N inverseBeep/2Min CommunicationRS232 interfaceYES Intelligent slotYES Monitor softwareAppending with UPS CoolingForce air cooling DisplayLCD/LED displays UPS statusEnvironmentWork temperature0ºC~40ºC Altitude<1000m Audible noise≤60dB Storage temperature-15ºC~45ºC Work humidity20%~95% StandardEMSESDIEC61000-4-2Level4RSIEC61000-4-3Level3EFTIEC61000-4-4Level4SurgeIEC61000-4-5Level4EMIConductedEN55022Class ARadiatedEN55022Class ASafetySafetyGB4943-2001/IEC62040-1 Machinery featuresSizeOutline dimension and net weightL*W*H (mm)710*260*717840*515*1135 Net weight(Kg)45/9350/98 195208 Optional functions60Hz OptionalSet by softwareConverter mode OptionalSet by softwareECOOptionalOptionalAvailable and set by softwareEPOOptionalOptional *Specification is subject to change without further notice