PE/XLPE Insulated ABC Cable, Duplex ABC Cable, Triplex ABC Cable manufacturer / supplier in China, offering ABC Cable with PE/XLPE Insulation (Duplex, Triplex, Quadruplex), Single Core XLPE Insulated Copper Wire Shield 11kv Aluminum Power Cable, Cooper Aluminum Conductor Power XLPE Insulation Cable and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Optical Fiber, Cable & Wire Electric Wire & Cable China Overhead Bundled Medium Voltage Aluminium XLPE 33kv ABC Cable

China Overhead Bundled Medium Voltage Aluminium XLPE 33kv ABC Cable

Get Latest Price
Min. Order / Reference FOB Price
1000 Meter US $3.50/ Meter
Local Area: Luoyang, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC
Brand: Huatong
Type: Insulated
Conductor Type: Stranded
Application: Overhead, Messenger Wire
Overhead bundled medium voltage aluminium XLPE 33kv abc cable
(1)Production capacity:5000km/month
(2)MOQ:1km
(3)Delivery:5~15 officail days.
(4)Standards:IEC,ASTM,DIN,BS; or according to customers' requirements.
Product Desription
(1) PHASE ConDUCTORS :
Phase conductors made of aluminium wires are circular stranded, rounded and compacted with smooth circular surface.Our products are avaible 16 mm2 as solid, 25 to 70 mm2 7 wired; from 95 mm2 to onwards as 19 wired confirming TS 11654.
(2) MESSENGER (NEUTRAL) ConDUCTOR :
Bare, round, stranded and compacted aluminium alloy (294 N/mm2).
(3) INSULATION :
Phase conductors of Aerial Bundled Cables are insulated by black coloured PE or XLPE which are weather resistant.
(4) CORE IDENTIFICATION :
Phase conductors two, three and four longitudinal ridges, street lighting conductor without ridges.
(5) USAGE AREA & ADVANTAGES OF ABC SYSTEMS
The usage of Aerial Bundled Cables in low voltage networks provides important saving in installation costs, while it ensures the same reliability and safety, replaces bare conductors in overhead distribution lines and increased very rapidly all around the world.
(6)Features:
-- Overhead insulated cable is safe & reliable, and it's with a simple structure, excellent mechanical properties and electrical properties.It's also with the environmental resistance and sunlight resistance.
--The insulation of overhead insulated cable is made of professional raw material with weather resistance. The long-term working temperature is up to 70 ºC to 90 ºC. It's with the excellent insulated property. The volume resistivity is above 1.0x10^12Ω·m.
-- During the laying, using the insulated overhead cable, the laying gap can be reduced, and saving cable, reduce the loss of voltage .
-- During the operating, the overhead insulated cable will reduce the power accidents and ensure personal safety.
-- Compared to the copper conductors aerial bundled cables are lighter and more economical. They can be used safely in wood, concrete and iron poles. The poles height's can be shorter instead of using 5 different sized lines, by ABC systems we can use only one line which save on time, effort and material. Lower inductive reactance of the aerial bundled cables reduces voltage drop and power losses.
Company information
Huatong Cable Inc.
(1),More than 30 years experience.
(2) ,100,000m² factory,200 staffs,annual output 100,000 metic tons.
(3),Sound Quality Control
--Material inspection;
--manufacturing inspection;
-- Finished products inspection;
-- Inspection before delivery.
--Third party inspection.
-- Inspection of storage at port of departure.
(4),ISO Certificated.
(5) ,Plenty of material and lobor gurantee the delivery prompt and price competitive.
(6),24/7 service.
ABC cable technical parameters
1. Duplex Service Drop-Aluminum Conductor
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards: ASTM B-230, B-231, B-232 and B-399 & ICEA S-76-474

Code
NamePhase ConductorBare Neutral MessengerWeight Per
1000 ft(lbs)Rating(Amps)Size
AWGStrandInsulation
thickness
(mls)Size
AWG*StrandBreaking
strength
(lbs)XLPPOLYXLPPOLYAACPekingese6solid4567/w56363.561.77070Collie67/w4567/w56366.863.17070Dachshund4solid4547/w88195.593.49090Spaniel47/w4547/w881100.595.49090Doberman27/w4527/w1,350152.7145.7120120Malemute1/019/w601/07/w1,990242.6234.2160160ACSR NEUTRAL-MESSENGERSetter6solid4566/11.19075.073.27070Shepherd67/w4566/11.19078.374.67070Eskimo4solid4546/11.860113.7111.69090Terrier47/w4546/11.860118.7113.69090Chow27/w4526/12.850181.7174.7120120Bull1/019/w601/06/14.380288.7280.31601606201 ALLOY NEUTRAL-MESSENGERChihuahua6solid4567/w1,11067.665.87070Vizsla67/w4567/w1,11070.967.27070Harrier4solid4547/w1,760102.099.99090Whippet47/w4547/w1,760107.0101.99090Schnauzer27/w4527/w2,800163.3156.2120120Heeler1/019/w601/07/w4,460259.2250.8160160


2. Triplex Service Drop-Aluminum Conductor
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral messenger.
Standards: ASTM B-230, B-231, B-232 and B-339 & ICEA S-76-474

Code
NamePhase ConductorBare Neutral MessengerWeight Per
1000 ft(lbs)Ampacity (Amps)Size
AWGStrandingInsulation
thickness
(mls)Size
AWGStrandingBreaking
strength
(lbs)XLPPOLYXLPPOLY6201 ALLOY NEUTRAL-MESSENGERMinex6solid45671,110106.6102.98570Hippa67/w45671,110113.2105.78570Prawn4solid45471,760158.4154.111590Barnacles47/w45471,760168.3158.211590Shrimp27/w45272,800253.7239.7150120Gammarus1/07/w601/074,460411.7386.0205160Leda1/019/w601/074,460402.7386.0205160Dungenese2/07/w602/075,390506.8476.3235185Cyclops2/019/w602/075,390495.3476.3235185Flustra3/019/w603/076,790611.4589.1275215Lepas4/019/w604/078,560757.1730.53152456201 ALLOY REDUCED NEUTRAL-MESSENGERArtemia4solid45671,110141.4137.111590Crab47/w45671,110151.3141.211590Solaster27/w45471,760226.6212.6150120Sandcrab1/07/w60272,800368.8343.1205160Echinus1/019/w60272,800358.8343.1205160Crayfish2/07/w60173,530452.6422.5235185Sipho2/019/w60173,530441.0422.5235185Fulgar3/019/w601/074,460543.4521.1275215Arca4/019/w602/075,390671.2644.6315245Code
NamePhase ConductorsBare NeutralWeight Per
1000 ft.(lbs)Ampacity (Amps)Size AWG
or MCMStrandingInsulation
thickness
(mls)Size
(AWG)*StrandingRated
strength
(lbs)XLPPolyXLPPolyAAC NEUTRAL-MESSENGERHaiotis6solid4567563102.598.88570Patella67/w4567563109.1101.68570Fusus4solid4547881151.9147.611590Oyster47/w4547881161.8151.711590Clam27/w45271,350243.2229.2150120Murex1/07/w601/071,990395.1369.4205160Purpura1/019/w601/071,990386.1369.4205160Nassa2/07/w602/072,510485.8455.3235185Melita3/019/w603/0193,310585.2562.9275215Portunus4/019/w604/0194,020723.9697.3315245Nannynose336.419/w80336.4196,1461160.41118.0420325WITH FULL SIZE ACSR MESSENGERPaludina6solid4566/11,1901141138570Voluta67/w4566/11,1901201138570Whelk4solid4546/11,86016916511590Periwinkle47/w4546/11,86017617211590Conch27/w4526/12,850267261150120Neritina1/07/w601/06/14,380530419205160Cenia1/019/w601/06/14,380426416205160Runcina2/07/w602/06/15,310530519235185Triton2/019/w602/06/15,310526514235185Cherrystone3/07/w603/06/16,620656643250200Mursia3/019/w603/06/16,620650638250200Razor4/07/w604/06/18,350814799315245Zuzara4/019/w604/06/18,350805792315245Limpet336.419/w80336.418/18,68012091167420325 Code
NamePhase ConductorsBare NeutralWeight Per
1000 ft.(lbs)Ampacity (Amps)Size AWG or MCMStrandingInsulation
thickness
(mls)Size
(AWG)StrandingRated
strength
(lbs)XLPPolyXLPPolyWITH ACSR REDUCED SIZE MESSENGERScallop4Solid4566/11,19014814411590Strombus47/w4566/11,19015814811590Cockle27/ w4546/11,860233227150120Janthina1/07/ w6026/12,850376365205160Ranella1/019/ w6026/12,850372362205160Cavolinia2/07/ w6016/13,550462451235185Clio2/019/ w6016/13,550458446235185Sanddollar3/07/ w601/06/14,380570557275215Aega3/019/ w601/06/14,380565552275215Cuttlefish4/07/ w602/06/15,310706691315245Cerapus4/019/ w602/06/15,310699684315245Cowry336.419/ w804/06/18,35011351093420325


3.Quadruplex Service Drop-Aluminum Conductor
Construction:
Conductors are concentrically stranded, compressed 1350-H19 aluminum, insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR, One conductor is manufactured with an extruded ridge for phase identification.
Standards: ASTM B-230, B-231, B-232, B-339 & ICEA S-76 -474

Code
NamePhase ConductorBare Neutral MessengerWeight Per
1000 ft(lbs)Rating(Amps)Size
AWGStrandInsulation
thickness
(mls)Size
AWGStrandBreaking
strength
(lbs)XLPPOLYXLPPOLYAAC NEUTRAL-MESSNGERClydesdale4Solid4547881208201.810080Pinto47/w4547881223207.910080Mustang27/w45271,350333312.6135105Criollo1/019/w601/071,990529504.5180140Percheron2/019/w602/072,510649620.5205160Hanoverian3/019/w603/0193,310799765.6235185Oldenburg4/019/w604/0194,020986946.7275210Lippizaner336.419/w80336.4196,1461,5461,519.2370280ACSR NEUTRAL-MESSNGERMorochuca6Solid4566/11,190152147.47560Chola67/w4566/11,190162151.77560Morgan4Solid4546/11,86022622010080Hackney47/w4546/11,860241226.110080Palomino27/w4526/12,850362342.6135105Costena1/019/w601/06/14,380575550.6180140Grullo2/019/w602/06/15,310707678.7205160Suffolk3/019/w603/06/16,620872838.9235185Appaloosa4/019/w604/06/18,35010791039.2275210Bronco336.419/w80336.418/18,58016131568.2370280Gelding336.419/w804/06/18,35015481494.3370280 Code
NamePhase ConductorBare Neutral MessengerWeight Per
1000 ft(lbs)Rating(Amps)Size
AWGStrandInsulation
thickness
(mls)Size
AWGStrandBreaking
strength
(lbs)XLPPOLYXLPPOLY6201 ALLOY NEUTRAL-MESSENGERBay6Solid45671,110145140.07560French Coach67/w45671,110155144.37560German Coach4Solid45471,760214208.310080Arabian47/w45471,760229214.410080Belgian27/w45272,800344323.1135105Shetland1/019/w601/074,460546521.1180140Thoroughbred2/019/w602/075,390670641.5205160Trotter3/019/w603/076,790825791.8235185Walking 4/019/w604/078,5601019979.7275