Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
OEM
OEM/ODM Service
Sample Available

Hiwin THK NSK Tbi Rolled Ballscrew, R1605-Fsi, R2005-Fsi manufacturer / supplier in China, offering Hiwin THK NSK Tbi Rolled Ballscrew/Precision Ground Ballscrew/Miniature Ground Ballscrews, Hiwin Hg Series Heavy Load Ball Type Linear Guidewayhgw20ha/HGH20ca/HGH30ca/Hgw30cc/Hgw35cc/Hgw25cc/HGH45cc/Hgw45hc, 2020 Disposable Protective Mask Disposable Dust Non-Woven Face Dust Face Masks and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Electrical Control System China PLC Splitter in Fiber Optic Equipent Fx5UC Fx5-Cnv-Ifc or Fx5-C1PS-5V PLC Light

China PLC Splitter in Fiber Optic Equipent Fx5UC Fx5-Cnv-Ifc or Fx5-C1PS-5V PLC Light

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $10000.00/ Piece
Local Area: Shanghai, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Task: Program
Structure: Open-Loop
Mathematical Model: Linear
MELSEC iQ-F series


Awarded the iF Design Award in 2016!
The German design award iF Design Award has a tradition of over 60 years and recognized all over the world. Next generation PLC MELSEC iQ-F series, developed from the user perspective to provide improved visual verification and prevent operation mistakes, was awarded the iF Design Award in 2016!

MELSEC iQ-F Series LineupFlagship model equipped with advanced built-in functions and diverse expandability

Simplifying use with renewed expansion modules!

FX5U is equipped with analog functions, communication and high-speed I/O, and can easily be expanded with expansion boards and adapters.
The high-speed system bus communication brings out the maximum performance of expansion devices equipped with intelligent functions.

Control scale32 to 384 points (CPU module: 32/64/80 points)
Max. 512 pts including CC-link, AnyWireASlink, and Bitty series remote I/OProgram memory128 k steps (Comment and statements in separate area)Built-in analog input/outputA/D 2 ch 12-bit
D/A 1 ch 12-bitBuilt-in SD Memory Card SlotMax. 16 GB (SD/SDHC memory card)
[Application]
Stores device comment file and folders/files created by functions using SD memory card.Built-in Ethernet Port10base-T/100base-TX
[Application]Socket communication (Direct connection to other PLCs)Remote maintenance (Read/write program with GX Works3 connected via VPN)SLMP Communication (Read/write PLC device data from PC)Built-in RS-485 portConforming to RS-485 and RS-422 standards
[Application]Inverter Communication (Max. length 50 m, max. 16 units can be connected)MODBUS® Communication (Up to 32 devices can be connected, including other PLCs, sensors, temperature controllers)Built-in
input/output
functionBuilt-in positioning4 axes 200 kHz pulse outputBuilt-in
high-speed counterMax. 8 ch 200 kHz high speed pulse input
(FX5U-32M: 6 ch 200 kHz + 2 ch 10 kHz)Compact body packed with diverse functions

Simplifying use with renewed expansion modules!

The expansion module compatible with FX5UC is compact and easy-to-use, and helps to downsize your system.
Easily connect to the FX5 and FX3 expansion modules with the variety of conversion modules available.

Control scale32 to 384 points (CPU module: 32/64/96 points)
Max. 512 pts including CC-link, AnyWireASlink, and Bitty series remote I/OProgram memory128 k steps (Comment and statements in separate area)Built-in SD Memory Card SlotMax. 16 GB (SD/SDHC memory card)
[Application]
Stores device comment file and folders/files created by functions using SD memory card.Built-in Ethernet Port10base-T/100base-TX
[Application]Socket communication (Direct connection to other PLCs)Remote maintenance (Read/write program with GX Works3 connected via VPN)SLMP Communication (Read/write PLC device data from PC)Built-in RS-485 portConforming to RS-485 and RS-422 standards
[Application]Inverter Communication (Max. length 50 m, max. 16 units can be connected)MODBUS® Communication (Up to 32 devices can be connected, including other PLCs, sensors, temperature controllers)Built-in
input/output
functionBuilt-in positioning4 axes 200 kHz pulse outputBuilt-in
high-speed counterMax. 8 ch 200 kHz high speed pulse input
(FX5UC-32M: 6 ch 200 kHz + 2 ch 10 kHz)FX5UJ with excellent cost performance that can be used in any scene

FX5UJ is equipped with various built-in functions to improve ease of use!

FX5UJ has an SD memory card slot, built-in USB (Mini-B) connector, and built-in Ethernet port as a standard.
In addition, built-in functions such as positioning and highspeed counters are included to condense various functions and ease of use.

Control scale24 to 256 points (CPU module: 24/40/60 points)
Max. 256 pts including CC-link, AnyWireASlink, and Bitty series remote I/OProgram memory48 k steps (Comment and statements in separate area)Built-in SD Memory Card SlotMax. 16 GB (SD/SDHC memory card)
[Application]
Stores device comment file and folders/files created by functions using SD memory card.Built-in Ethernet Port10base-T/100base-TX
[Application]Socket communication (Direct connection to other PLCs)Remote maintenance (Read/write program with GX Works3 connected via VPN)SLMP Communication (Read/write PLC device data from PC)Built-in USB connectorMini-B (Data transfer speed: Max. 12 Mbps)
[Application]
Connections with GX Works3 can be established with just a single cable.Built-in
input/output
functionBuilt-in positioning3 axes 200 kHz pulse outputBuilt-in
high-speed counter4 ch 200 kHz + 4 ch 10 kHz high speed pulse input

Powered I/O module

ModelTotal No.
of pointsNo. of input/output points
& Input/output typeConnection typeCompatible CPU moduleInputOutputFX5UFX5UCFX5UJAC power supply type FX5-32ER/ES32 points16 points24 V DC
(sink/source)16 pointsRelayScrew terminal block○x○FX5-32ET/ESTransistor (sink)FX5-32ET/ESSTransistor (source)DC power supply type FX5-32ER/DS32 points16 points24 V DC
(sink/source)16 pointsRelayScrew terminal block○*
○xFX5-32ET/DSTransistor (sink)FX5-32ET/DSSTransistor (source)

*: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page topInput module

ModelTotal No.
of pointsNo. of input/output points
& Input/output typeConnection typeCompatible CPU moduleInputOutputFX5UFX5UCFX5UJ FX5-8EX/ES8 points8 points24 V DC
(sink/source)--Screw terminal block○*1
○○ FX5-16EX/ES16 points16 points FX5-C16EX/D16 points16 points24 V DC
(sink)--Connector*2
○○*2
○FX5-C16EX/DS24 V DC
(sink/source) FX5-C32EX/D32 points32 points24 V DC
(sink)FX5-C32EX/DS24 V DC
(sink/source) FX5-C32EX/DS-TS32 points32 points24 V DC
(sink/source)--Spring clamp terminal block*2
○○*2

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.

page topOutput module

ModelTotal No.
of pointsNo. of input/output points
& Input/output typeConnection typeCompatible CPU moduleInputOutputFX5UFX5UCFX5UJ FX5-8EYR/ES8 points--8 pointsRelayScrew terminal block○*1
○○FX5-8EYT/ESTransistor (sink)FX5-8EYT/ESSTransistor (source) FX5-16EYR/ES16 points16 pointsRelayFX5-16EYT/ESTransistor (sink)FX5-16EYT/ESSTransistor (source) FX5-C16EYR/D-TS16 points--16 pointsRelaySpring clamp terminal block*2
○○*2
○ FX5-C16EYT/D16 points--16 pointsTransistor (sink)Connector*2
○○*2
○FX5-C16EYT/DSSTransistor (source) FX5-C32EYT/D32 points32 pointsTransistor (sink)FX5-C32EYT/DSSTransistor (source) FX5-C32EYT/D-TS32 points--32 pointsTransistor (sink)Spring clamp terminal block*2
○○*2
○FX5-C32EYT/DSS-TSTransistor (source)

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.

page topInput/output module

ModelTotal No.
of pointsNo. of input/output points
& Input/output typeConnection typeCompatible CPU moduleInputOutputFX5UFX5UCFX5UJ FX5-16ER/ES16 points8 points24 V DC (sink/source)8 pointsRelayScrew terminal block○*1
○○FX5-16ET/ESTransistor (sink)FX5-16ET/ESSTransistor (source) FX5-C32ET/D32 points16 points24 V DC (sink)16 pointsTransistor (sink)Connector*2
○○*2
○FX5-C32ET/DSS24 V DC (sink/source)Transistor (source) FX5-C32ET/DS-TS32 points16 points24 V DC (sink/source)16 pointsTransistor (sink)Spring clamp terminal block*2
○○*2
○FX5-C32ET/DSS-TSTransistor (source)

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: When connecting to FX5U or FX5UJ, FX5-CNV-IF is required.

page topHigh-speed pulse input/output module

ModelTotal No.
of pointsNo. of input/output points
& Input/output typeConnection typeCompatible CPU moduleInputOutputFX5UFX5UCFX5UJ FX5-16ET/ES-H16 points8 points24 V DC (sink/source)8 pointsTransistor (sink)Screw terminal block*1
○*1 *2
○xFX5-16ET/ESS-HTransistor (source)

*1: Supported in version 1.030 or later.

Analog input devices (A/D conversion)

ModelInput specificationsCompatible CPU
moduleNumber of channelsItemInput voltageInput currentFX5UFX5UCFX5UJ FX5U CPU module2 chInput
range0 to 10 V DC
(input resistance 115.7 kΩ)----Resolution2.5mV- FX5-4AD-ADP4 chInput
range-10 to +10 V DC
(Input resistance 1 MΩ)-20 to +20 mA DC
(Input resistance 250 Ω)○
Max.
4 units○
Max.
4 units○
Max.
2 unitsInput characteristics,
resolutionAnalog
Input rangeResolutionAnalog
Input rangeResolution10 to 10 V625 μV0 to 20 mA1.25 μA0 to 5 V312.5 μV4 to 20 mA1.25 μA1 to 5 V312.5 μV-20 to 20 mA2.5 μA-10 to 10 V1250 μV FX5-4AD4 chInput
range-10 to +10 V DC
(Input resistance 400 kΩ or more)-20 to +20 mA DC
(Input resistance 250 Ω)○*1
○○Input characteristics,
resolutionAnalog
Input rangeResolutionAnalog
Input rangeResolution0 to 10 V312.5 μV0 to 20 mA625 nA0 to 5 V156.25 μV4 to 20 mA500 nA1 to 5 V125 μV-20 to +20 mA625 nA-10 to +10 V312.5 μVUser range
setting125 μVUser range
setting500 nA FX5-8AD8 chInput
range-10 to 10 V DC
(Input resistance 1 MΩ)-20 to +20 mA DC
(Input resistance 250 Ω)○*1
○○Input characteristics,
resolutionAnalog
Input rangeResolutionAnalog
Input rangeResolution0 to 10 V312.5 μV0 to 20 mA625 nA0 to 5 V156.25 μV4 to 20 mA500 nA1 to 5 V125 μV-20 to +20 mA625 nA-10 to +10 V312.5 μV FX3U-4AD4 chInput
range-10 to +10 V DC
(input resistance 200 kΩ)-20 to +20 mA DC,
4 to 20 mA
(Input resistance 250 Ω)*2

Max.
Max. 6 to 8 modules
*3*2

Max.
6 unitsxResolution0.32 mV
(20 Vx1/64000)1.25 μA
(40 mAx1/32000)

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.

page topAnalog output devices (D/A conversion)

ModelOutput specificationsCompatible CPU
moduleNumber of channelsItemOutput voltageOutput currentFX5UFX5UCFX5UJ
FX5U CPU module1 chOutput
range0 to 10 V DC
(External load resistance value 2 kΩ to 1 MΩ)----Resolution2.5 mV-
FX5-4DA-ADP4 chOutput
range-10 to +10 V DC
(External load resistance value 1 kΩ to 1 MΩ)0 to 20 mA DC
(External load resistance value 0 to 500 Ω)○
Max.
4 units○
Max.
4 units○
Max.
2 unitsOutput characteristics,
resolutionAnalog
Output rangeResolutionAnalog
Output rangeResolution0 to 10 V625 μV0 to 20 mA1.25 μA0 to 5V312.5 μV1 to 5V250 μV4 to 20 mA1 μA-10 to 10 V1250 μV
FX5-4DA4 chOutput
range-10 to +10 V DC
(External load resistance value 1 kΩ to 1 MΩ)0 to 20 mA DC
(External load resistance value 0 to 500 Ω)○*1
○○Output characteristics,
resolutionAnalog
Output rangeResolutionAnalog
Output rangeResolution0 to 10 V312.5 μV0 to 20 mA625 nA0 to 5 V156.3 μV1 to 5 V125 μV4 to 20 mA500 nA-10 to +10 V312.5 μVUser range
setting312.5 μVUser range
setting500 nA
FX3U-4DA4 chOutput
range-10 to +10 V DC
(external load resistance value 1 kΩ to 1 MΩ)0 to 20 mA DC,
4 to 20 mA DC
(External load resistance value 500 Ω or less)*2

Max.
6 to 8 modules
*3*2

Max.
6 unitsxResolution0.32 mV
(20 V x 1/64000)0.63 μA
(20 mA x 1/32000)

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.

page topInput device for temperature sensor

ModelNumber of channelsAvailable sensorInput specificationsCompatible CPU
moduleItemTemperature inputFX5UFX5UCFX5UJ FX5-4AD-PT-ADP4 chUsable resistance temperature detector
Pt100
Ni100Input
range[Typical example]
Pt100: -200 to +850˚C
Ni100: -60 to +250˚C○
Max.
4 units○
Max.
4 units○
Max.
2 unitsResolution0.1˚C FX5-4AD-TC-ADP4 chThermocouple
K, J, T,
B, R, SInput
range[Typical example]
K type: -200.0 to 1200˚C
J type: -40.0 to 750˚C○
Max.
4 units○
Max.
4 units○
Max.
2 unitsResolution0.1 to 0.3˚C
(depending on the sensor used) FX5-8AD8 chUsable resistance temperature detector
Pt100
Ni100Input
range[Typical example]
Pt100: -200 to +850˚C
Ni100: -60 to +250˚C○*1
○○Resolution0.1˚CThermocouple
K, J, T,
B, R, SInput
range[Typical example]
K type: -270.0 to 1200˚C
J type: -40.0 to 750˚CResolution0.1 to 0.3˚C
(depending on the sensor used) FX5-4LC4 chPlatinum resistance thermometer sensor
Pt100, JPt100, Pt1000Input
range[Typical example]
3-wire Pt100: -200 to 600˚C
3-wire JPt100: -200 to 500˚C
2-wire/3-wire Pt1000: -200.0 to 650.0˚C○*1
○○Resolution0.1˚C or 1˚C
(depending on the sensor used)Thermocouple
K, J, R, S,
E, T, B, N JIS C 1602-1995,
PLII, W5Re/W26Re, U, LInput
range[Typical example]
K type: -200.0 to 1300˚C
J type: -200.0 to 1200˚CResolution0.1˚C or 1˚C
(depending on the sensor used)Micro voltage inputInput
range0 to 10 mV DC
0 to 100 mV DCResolution0.5 μV or 5.0 μV
(depending on the sensor used) FX3U-4LC4 chPlatinum resistance thermometer sensor
Pt100, JPt100, Pt1000Input
range[Typical example]
3-wire Pt100: -200 to 600˚C
2-wire/3-wire Pt1000: -200.0 to 650.0˚C*2

Max.
6 to 8
modules
*3*2

Max.
6 unitsxResolution0.1˚C or 1˚C
(depending on the sensor used)Thermocouple
K/J/R/S/E/T/B/
N/PLII/W5Re/
W26Re/U/L typeInput
range[Typical example]
K type: -200.0 to 1300˚C
J type: -200.0 to 1200˚CResolution0.1˚C or 1˚C
(depending on the sensor used)Low voltage inputInput
range0 to 10 mV DC
0 to 100 mV DCResolution0.5 μV or 5.0 μV
(depending on the sensor used)

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.

High speed counter

ModelNumber of channelsTypeHighest response
frequencyHardware
comparison output function2-phase counter
edge count functionCompatible CPU moduleFX5UFX5UCFX5UJ FX3U-2HC2 ch1 phase
1 inputMax. 200 kHz○-*

Up to
2 modules*

Up to
2 modulesx1 phase
2 inputMax. 200 kHz2 phase
2 input1 edge count: Max. 200 kHz
2 edge count: Max. 100 kHz
4 edge count: Max. 50 kHz○

*: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

page topHigh-speed pulse input/output module

ModelGeneric SpecificationsFunctionCompatible CPU moduleFX5UFX5UCFX5UJ FX5-16ET/ES-HMax. 2 ch 200 kHzHigh-speed counter function
- Normal mode
Pulse Width Measurement Function
Pulse Catch Function
General-purpose Input Functions*1

Up to 4 modules*1*2

Up to 4 modulesxFX5-16ET/ESS-H

*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page topFX5U/FX5UC/FX5UJ CPU module built-in input functions (Built-in high-speed counter function)

ModelGeneric SpecificationsFunction FX5U CPU moduleMax. 8ch 200kHz
FX5U-32M: 6 ch 200kHz + 2 ch 10kHzHigh-speed counter function
- Normal mode
- Pulse density measurement mode
- Rotation speed measurement mode
FX3-compatible high-speed counter function
Pulse Width Measurement Function
Pulse Catch Function
- Pulse Catch Function
- FX3-Compatible Pulse Catch Function
General-purpose Input Functions FX5UC CPU moduleMax. 8 ch 200kHz
FX5UC-32M: 6 ch 200kHz + 2 ch 10kHz FX5UJ CPU moduleMax. 4 ch 100kHz + 4 ch 10 Hz

Simple Motion Module (SSCNET III/H)

ModelNumber of control axesMain functions/ControlCompatible CPU moduleFX5UFX5UCFX5UJ FX5-40SSC-S4 axesFunction
Linear interpolation
Circular interpolation
Continuous trajectory control
S-curve acceleration/deceleration
Control
Synchronous control
Cam control
Torque control○
Up to
16 modules*1

Up to
8 modules*2

Up to
1 modules FX5-80SSC-S8 axesFunction
Linear interpolation
Circular interpolation
Continuous trajectory control
S-curve acceleration/deceleration
Control
Synchronous control
Cam control
Torque control○
Up to
16 modules*1

Up to
8 modules*2

Up to
1 modules

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.
*2: FX5-40SSC-S and FX5-80SSC-S cannot be used together.

page topHigh-speed pulse input/output module

ModelNumber of control axesMaximum frequencyCompatible CPU moduleFX5UFX5UCFX5UJ FX5-16ET/ES-H2 axes200 kpps*1

Up to 4 modules*1 *2

Up to 4 modulesxFX5-16ET/ESS-H

*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page topPositioning module

ModelNumber of control axesMaximum frequencyCompatible CPU moduleFX5UFX5UCFX5UJ FX5-20PG-P2 axes200 kpps○*1
○○ FX5-20PG-D2 axes5 Mpps○*1
○○ FX3U-1PG1 axis200 kpps*2

Max.
6 to 8 modules
*3*2

Max.
6 modulesx

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

*3: When FX3U-1PSU-5V is used, max. is 8 modules. When FX3U-1PSU-5V is not used, max. is 6 modules.

page topFX5U/FX5UC/FX5UJ CPU module built-in output functions (Built-in positioning function)

ModelGeneric SpecificationsFunction FX5U CPU moduleMax. 200 kHz 4 axes
*Supported by transistor output type CPU moduleJOG operation (Supported by variable speed operation)
Machine home position return
Fast home position return control
1-speed positioning
2-speed positioning
Multi-speed operation
Interrupt stop
Interrupt and 1-speed positioning
Interrupt and 2-speed positioning
Variable speed operation
Simple linear interpolation (Start 2-Axis simultaneously)
Table operation
Absolute position detection system FX5UC CPU module FX5UJ CPU moduleMax. 200 kHz 3 axes
*Supported by transistor output type CPU module

CC-link IE field network

ModelMaster station functionRemote,
slave functionDistanceCompatible CPU moduleFX5UFX5UCFX5UJ FX5-CCLIEF
CC-link IE field network
(Intelligent device station)x○100 m*1

Up to 1 module*1 *2

Up to 1 module○
Up to 1 module

*1: Supported in version 1.030 or later.
*2: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page topCC-link

ModelMaster station functionRemote,
slave functionDistanceCompatible CPU moduleFX5UFX5UCFX5UJ FX5-CCL-MS
CC-link system
master/intelligent
device module○○1200 m○*1
○○ FX3U-16CCL-M *2
CC-link
(Master station)○x1200 m*3

Up to
1 module*3

Up to
1 modulex FX3U-64CCL
CC-link
(Intelligent device station)x○

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*2: When CC-link master and AnyWire Bitty master or AnyWireASlink master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASlink master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user's manuals.

*3: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

page topEthernet

ModelData
transmission speedMaximum
segment lengthSupported protocolNo. of connections FX5U CPU module100 / 10 Mbps100 m
(The distance between hub and node)CC-link IE field network Basic
FTP Server
SNTP client
Web server (HTTP)
Simple CPU communication function
MELSOFT connection
SLMP (3E frame)
Socket communication
Predefined protocol support
MODBUS/TCP communicationTotal of 8 connections*1*2
(Up to 8 external devices are accessible to one CPU module at a time.) FX5UC CPU module FX5UJ CPU module FX5-ENET
Ethernet module

CC-link IE field network Basic
Socket communication

Total of 32 connections*3
(Up to 32 external devices are accessible to one FX5-ENET at a time.) FX5-ENET/IP
EtherNet/IP module

EtherNet/IP
Socket communication

Total of 32 connections
(Up to 32 external devices are accessible to one FX5-ENET/IP at a time.)

*1: The first device for MELSOFT connection is not included in the number of connections. (The second and the following devices are included.)

*2: The CC-link IE field network Basic, FTP server, SNTP client, Web server and simple CPU communication function are not included in the number of connections.

*3: The CC-link IE field network Basic are not included in the number of connections.

page topEtherNet/IP

ModelData
transmission speedMaximum
segment lengthSupported protocolCompatible CPU moduleFX5UFX5UCFX5UJ FX5-ENET/IP
EtherNet/IP module100 / 10 Mbps100 m
(The distance between hub and node)

Class 1 communications
Class 3 communications
UCMM communications


Up to 1 module*1

Up to 1 module○
Up to 1 module

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page topPROFIBUS-DP

ModelTransmission protocolCompatible CPU moduleFX5UFX5UCFX5UJ FX5-DP-M
PROFIBUS-DP Master modulePROFIBUS-DP○
Up to 1 module*1

Up to 1 module○
Up to 1 module

*1: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page topSensor Solution

ModelTransmission protocolNumber of connected I/O pointsCompatible CPU moduleFX5UFX5UCFX5UJ FX5-ASL-M
AnyWireASlink system master moduleDedicated protocol
(AnyWireASlink)448 points maximum *1*2*3
(input: maximum 256 points,
output: maximum 256 points)○
Up to
1 module*4

Up to
1 module○
Up to
1 module FX3U-128BTY-M *5
AnyWire Bitty series
masterDedicated protocol
(AnyWire Bitty)Up to 128 points*6

Up to
1 module*6

Up to
1 modulex FX3U-128ASL-M *5
AnyWireASlink system masterDedicated protocol
(AnyWireASlink)

*1: The number of available remote I/O points per system varies depending on the number of I/O points of the extension devices.
*2: The maximum number of points that can be used differs depending on the version of the CPU module used.

*3: When connecting to the FX5UJ CPU module, the maximum is 216 points (input: maximum 192 points, output: maximum 192 points).

*4: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to the FX5UC CPU module.

*5: When CC-link master and AnyWire Bitty master or AnyWireASlink master are used together, connect to the front stage (left side) of AnyWire Bitty master and AnyWireASlink master. When used together, please refer to the FX3U-128ASL-M, FX3U-128BTY-M, and FX3U-16CCL-M user's manuals.

*6: When connecting to FX5U or FX5UC, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.

page topMODBUS communication

ModelCommunication interfaceMaximum transmission distanceGeneric SpecificationsCompatible CPU moduleFX5UFX5UCFX5UJ FX5-232-BDRS-232C15 mPredefined protocol: RTU
No. of connectable slaves: 1○
Up to
1 modulesx○
Up to
1 modules FX5-232ADP○
Up to
2 modules○
Up to
2 modules○
Up to
2 modules FX5U CPU moduleRS-48550 mPredefined protocol: RTU
No. of connectable slaves: 32--- FX5UC CPU module--- FX5-485-BD50 m○
Up to
1 modulex○
Up to
1 module FX5-485ADP1200 m○
Up to
2 module○
Up to
2 module○
Up to
2 module

page topSerial communication

ModelCommunication interfaceMaximum transmission distanceFunction typeCompatible CPU moduleFX5UFX5UCFX5UJ FX5-232-BDRS-232C15 mMELSOFT connection
MELSEC Communication protocol (1C/3C/4C frames)
Non-protocol communication
Predefined protocol support○
Up to
1 modulex○
Up to
1 module FX5-232ADP○
Up to
2 module○
Up to
2 module○
Up to
2 module FX5U CPU moduleRS-48550 mMELSOFT Connection
MELSEC Communication protocol (1C/3C/4C frames)
Non-protocol communication
Inverter communication
N:N network
Parallel link
Predefined protocol support--- FX5UC CPU module--- FX5-485-BD50 m○
Up to
1 modulex○
Up to
1 module FX5-485ADP1200 m○
Up to
2 module○
Up to
2 module○
Up to
2 module FX5-422-BD-GOTRS-422As per GOT specificationsGOT connection○
Up to
1 module-○
Up to
1 module

Safety main module

ItemTotal No. of pointsSafety inputsSafety outputsSafety integrity level (SIL)Performance level (PL)Off delay timeBuilt-in programConnection typeCompatible CPU moduleFX5UFX5UCFX5UJ FX5-SF-MU4T58 points4 points4 pointsSIL3 (IEC 61508)PL e (DIN EN ISO 13849-1)0 / 0.5 / 1 /1.5 / 2 / 2.5 / 3 / 3.5 / 4 / 5 s9 typesSpring clamp terminal block○*
○x

*: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

page topSafety expansion moduleSafety input expansion module

ItemTotal No. of pointsSafety inputsSafety outputsSafety integrity level (SIL)Performance level (PL)Off delay timeBuilt-in programConnection typeCompatible CPU module*3FX5UFX5UCFX5UJ FX5-SF-8DI48 points8 points0 pointsSIL3 (IEC 61508)PL e (DIN EN ISO 13849-1)*1*2
9 typesSpring clamp terminal block○*4
○x

*1: Set the off delay time in the safety main module.
*2: The built-in program can set the logical path connection method with the safety main module for INPUT A and INPUT B each.
*3: Safety main module is required to connect to the CPU modules.
*4: When connecting to FX5UC, FX5-CNV-IFC or FX5-C1PS-5V is required.

Extension power supply module

ModelSpecificationsCompatible CPU moduleFX5UFX5UCFX5UJ FX5-1PSU-5VPower supply for FX5 extension module
Internal 5V DC: 1.2 A *1
Internal 24 V DC: 0.3 A *1○ (AC power supply type)
Up to 2 modules
*3x○
Up to
1 module FX3U-1PSU-5VPower supply for FX3 extension module
Internal 5 V DC: 1 A *1
Internal 24 V DC: 0.3 A *1*2
○ (AC power supply type)
Up to 2 modules
*3xx FX5-C1PS-5VPower supply for FX5 extension module
[Output current]
5 V DC: 1200 mA *1
24 V DC: 625 mA *1

*4
○ (DC power supply type)
Up to 2 modules


Up to
2 modulesx

*1: Maximum output current depends on the ambient temperature.
*2: When connecting to FX5U, FX5-CNV-BUS or FX5-CNV-BUSC is required. Select one according to the system configuration.
*3: Max. of total two FX5-1PSU-5V and FX3U-1PSU-5V can be connected in one system.
*4: When connecting to FX5U, FX5-CNV-IF is required.

page topConnector conversion module

ModelSpecificationsCompatible CPU moduleFX5UFX5UCFX5UJ FX5-CNV-IFConnector conversion module used from FX5 (extension cable type)
to connect FX5 (extension connector type) extension modules.
Control power: not consumed○
Up to
1 modulex○
Up to
1 module FX5-CNV-IFCConnector conversion module used from FX5 (extension connector type)
to connect FX5 (extension cable type) extension modules.
Control power: not consumedx○
Up to
1 modulex

page topConnector conversion adapter

ModelSpecificationsCompatible CPU moduleFX5UFX5UCFX5UJ FX5-CNV-BCConnector conversion adapter○
Up to
1 module○
Up to
1 module○
Up to
1 module

page topExtension cable

ModelLengthApplicationCompatible CPU moduleFX5UFX5UCFX5UJ FX5-30EC0.3mExtension cable for extension module○
Up to
1 module○
Up to
1 module○
Up to
1 moduleFX5-65EC0.65m

page topBus conversion module

ModelSpecificationsCompatible CPU moduleFX5UFX5UCFX5UJ FX5-CNV-BUSBus conversion FX5 (extension cable type) -> FX3 extension
Control power: 5 V DC 150 mA (supplied from PLC)○
Up to
1 module*1

Up to
1 modulex FX5-CNV-BUSCBus conversion FX5 (extension connector type) -> FX3 extension
Control power: 5 V DC 150 mA (supplied from PLC)*2

Up to
1 module○
Up to
1 modulex

*1: FX5-CNV-IFC or FX5-C1PS-5V is necessary to connect to FX5UC.
*2: FX5-CNV-IF is necessary to connect to FX5U.

page topTerminal modules

Terminal modules are used to convert connector-type I/O terminals into terminal blocks.
By using terminal blocks (built-in element type) dedicated to input or output, capturing of AC input signals and format conversion into the relay/transistor/triac output can be performed.

ModelNo. of input
pointsNo. of output
pointsFunction FX-16E-TB16 input points or 16 output pointsDirectly connected to the I/O terminal of PLC.
Using this unit instead of a terminal block or relaying a wiring of I/O device located remotely from PLC enables reducing of the man-hours of I/O wiring.FX-16E-TB/UL FX-32E-TB32 input points, 32 output points, or
16 input points and 16 output pointsFX-32E-TB/UL FX-16EYR-TB-16 pointsRelay output typeFX-16EYR-ES-TB/ULFX-16EYS-TBTriac output typeFX-16EYS-ES-TB/ULFX-16EYT-TBTransistor output type (sink)FX-16EYT-ES-TB/ULFX-16EYT-ESS-TB/ULTransistor output type (source)

page topSD memory card

ModelSpecificationsCompatible CPU moduleTypeCapacityNumber of writesFX5UFX5UCFX5UJNZ1MEM-2GBSDSD memory card2G bytes60,000 times○
Up to
1 module○
Up to
1 module○
Up to
1 moduleNZ1MEM-4GBSDSDHC memory card4G bytes100,000 timesNZ1MEM-8GBSD8G bytesNZ1MEM-16GBSD16G bytes

page topBattery

ModelApplicationCompatible CPU moduleFX5UFX5UCFX5UJ FX3U-32BLThe battery will be used when you desire to retain (latch) * the status of the device memory or clock data before a power failure.
At the time of delivery from a plant, the battery is not built in the CPU module.
Please make arrangements if required.○
Up to
1 module○
Up to
1 modulex

*: Setting of parameter is required for a power failure retention.

page topCable

ModelLengthApplication FX-232CAB-13.0 mUse a communication cable to connect a PLC with a personal computer by RS-232C communication.
FX5-232ADP <-> Personal computer
FX5-232-BD * <-> Personal computer

*: FX5-232-BD can be connected to the FX5U/FX5UJ CPU module.