Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Dynamometer, Dynamometer Prices, Digital Dynamometer manufacturer / supplier in China, offering Cheap Price Push Pull Digital Dynamometer, Yds-2 2L Storage-Type Liquid Nitrogen Container with Ce Approval, Shz-95A Water Circulating Pump with Ce Proved and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Optical Lens & Instrument Spectrometer China Particle Size Analyzer Laser Particle Size Analyzer Particle Analyzer

China Particle Size Analyzer Laser Particle Size Analyzer Particle Analyzer

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $7521.00/ Piece
Local Area: Zhengzhou, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Application: Laboratory Apparatus
Warranty: > 1Year
Detection Method: Laser Particle

Laser Particle Size Analyzer for powder size testingIntroduce:
LS-POP (9) is a new cost-effective laser particle size analyzer designed and manufactured by Omec relying on powerful R&D managerial experience from Spectris and combining the market application features of LS-POP(6)- the star product and sales champion at present after Omec joining in UK Spectris plc. It will bring a feeling of freshness to powder industry with higher testing performance.Applications:
Measure the particle size distribution of powder or latex.Principle:
Light is an electromagnetic wave. When light meets with particles on it way of traveling, the interaction between light and particles will result in deviations of part of the light, which is called light scattering. The bigger the scattering angle is, the particle size will be smaller, the smaller the scattering angle is, the particle size will be bigger. The particle analyzer instFastener & Fitting ruments will analysis the particle distribution accorGeographic Surveying Instrument ding to this physical character of the light wave.Specifications:
1. Theory: Mie scattering
2.: Measuring Range: 0.1~750μm
3. Sample Feeding: wet dispersion
4.Fire Control Repeatability: <1% (standard sample D50)
5. Scan frequency: 1 kHz
6. Measurement Duration: 1-2 minutes
7. Number of Detectors: 49
8. Light Source: He-Ne laser, 2.0 mW, 0.6328 μm
9. Environmental Requirement:
Temperature: 5-35ºC
Humidity:<85%
10. Report Items: Particle size distribution table & graph, Average diameter, Median diameter, SSA, etc.
11. Dimension(L X W X H):838 X 265 X 295mm(mainframe)Product imageTechnical features Reliable optical platform
1. Use horizontal straight light path layout, no reflecting prism, light path is stable and reliable.
2. Good designability for base, good consistency of light path.
3. GB/T4857.18 drop test has been passed.
4. Anti-moist ability of laser power module and the stability of electric are better.
5. Modular construction design, maintenance is more convenient.
6. The testing performance for small particles is improved.
7. The all-in-one housing design, it's dust-protected and water-proof.Schematic diagram of optical path
1. Totally enclosed design of light path system, dust pollution and external light pollution can be prevented.
2. Light path adopts lens back Fourier transform structure.
3. Optical source adopts He-Ne laser emitter which owns better monochromaticity, high coherence, small divergence angle and good stability compared to other laser emitters,
we also adopt the patent design of integrated laser emitter(patent no.: 00228952.0) which reduces heat distortion of laser tube and external mechanical vibration.
4. For laser emitter, except for traditional detection of output power value, we add the stability test of output power.
5. Smoothing processing technology is used to reduce the impact of power fluctuation to measurement.
6. Constant current limit and filling process of laser tube are used to reduce the flash frequency to the minimum.
7. Backward detector is added, the lower limit of measurement is extended to 0.1micron.
8. Spatial filter is fixed by powerful permanent magnet, the pinhole is not easy to shift under the disturbance of external force, so the stability of the optical path has been
greatly improved. Besides, the new designed spatial filter eliminates the laser diffraction ring more effectively, the light background of the instrument is lower, optical energy data is more accurate, it is helpful to improve the testing capability for large particles.
9. Detector array adopts unique scattered light detection around a sphere surface (DAS) (patent no.: 95223756.3), the large angle detectors are placed in a spherical surface to get accurate focus of the large angle scattered light.Advanced data collection and processing technology
1.New designed data collecting board uses 32 bit CPU from famous chip design company-ARM,the CPU has the advantages of high-effective signal processing capacity and low power
consumption.
2.Using 8-channel simultaneous sampling to sample 16 bit ADC, the sampling frequency of frame data can reach 1 kHz.
3.Using 64-channel simultaneous sampling technology and sample & hold switch with ultralow leakage current, the full scale accuracy can reach 0.15%.
4.Easy to update the firmware and layout data, more convenient for maintenance and operation
5.Offset function of electric background, it can help to get more accurate optical energy data.

Packing image

•Our company
•Contact Us