Application of Power supply test equipment three phase phantom load set GF303B portable power source, CE, ISO approved, excellent working performance
It is suitable for all the power supply company, electric power company distribution network automation departments, is also suitable for petrochemical, coal mine, railway and steel industry etc, to power automation departments use.
Functions and Product Features
1. Weight home the most light: The integrated module, weight of 6.8 kg;
2. The fastest output (10 ms): By high performance 32 bit CPU, the frequency of 1.2 G;
3 Stable fastest (1 s): Hardware PID, the output of the standard resource without delay, fast response;
4. With the strongest load, load regulation rate fast, single phase with resistance sex load 15 VA; With pure capacitive load (0.33 UF);
5. Harmonic supreme: Standard device can output 2-63 times higher harmonic;
6. Stability, and the best, stability for 0.01% / min; English or Chinese display.
7. Two kinds of frequency output: But at the same time points in different frequency voltage output; And amplitude can adjust arbitrarily output;
8. Software powerful, the operation is simple, convenient, quick, three steps can complete verification;
9. Debugging far move communication protocols of the most, as many as 20 kinds, covering domestic all factories statue;
10. The fastest verification;
Technical Data
Electrical parametersAC Voltage outputAC Current outputPower outputPhasePower factor FrequencyHarmonic content (compared with fundamental wave)HarmonicMechanical parametersEnvironmental conditions
Accuracy class 0.05%, 0.1%Power supplySingle phase AC 85V-265V, 50/60 HzCommunication PortRS232, USBRange (U1, U2, U3 phase)0-140V; (0-264V option)Adjustment resolution0.01%, 0.1%, 1%, 10%,Accuracy0.05% RGStability0.01% RG / 1 minDistortion degreeBetter than 0.1% (not capacitive load)Load Capacity15VAFull load regulation rate0.02% RGFull load regulation timeLess than 1mSTemperature drift16 PPM/°CLong-term stability60 PPM/yearRange (I1, I2, I3 phase)0-6AAdjustment resolution0.01%, 0.1%, 1%, 10%, Accuracy0.05% RGStability0.01% RG/1minDistortion degreeBetter than 0.1% (not capacitive load)Load capacity15VAFull load regulation rate0.02% RGFull load regulation timeLess than 1mSTemperature drift16 PPM/°CLong-term stability60 PPM/yearActive power accuracy0.05%Reactive power accuracy0.1%Stability0.01% RG/1minRange0°-359.99°Adjustment resolution0.01°, 0.1°, 1°, 10°Accuracy0.05°Adjusting range-1 ~ 0 ~ + 1Resolution0.0001Accuracy0.0005Range40-65 HzAdjustment resolution0.001 Hz, 0.01 Hz, 0.1 Hz, 1HzAccuracy0.002 HzTemperature drift0.5 PPM/°C Long-term stability4 PPM/yearVoltage≤40%Current≤40%Phase0°-360°Harmonic times2-63Adjustment resolution0.1% (compared with fundamental wave)Dimensions (WxDxH) (mm)300x400x120Weight (kg)6.8Working temperature0°C to 40°C Storage conditions-30°C to 60°C Relative humidity≤85%