Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Electronic Instrument Calibrator China Portable 1000A Gfuve Primary Current Injection Test System with Timer

China Portable 1000A Gfuve Primary Current Injection Test System with Timer

Get Latest Price
Min. Order / Reference FOB Price
1 Set US $8000.00/ Set
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Brand: Gfuve
Application: Electromagnetic Instrument
Power: Electricity
Certification: CE, CCC, ISO9001:2015
TEST-901 PORTABLE 1000A GFUVE PRIMARY CURRENT INJECTION TEST SYSTEM WITH TIMER

TEST-901 1000a primary current injection test system adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current. GFUVE test-901's function is better than Megger products.
Application
Primary current injection testing is utilised in high current/high voltage scenarios found at large electrical installations such as substations. A large current (between 100A and 20,000A depending on system specifications and test requirements) is injected directly on the primary side of the electrical system such as a circuit breaker. The objective of the test is to identify how the system operates under various levels of current load.
Primary injection testing is suitable for testing over-current trip relays attached to a circuit breaker. By injecting the current into the system we can measure if the breaker will trip or fail, and how long the current is live before the circuit is broken.
Circuit breakers can go long periods of time without activation, and failure at the moment of activation can cause catastrophic damage to the electrical system. Circuit breaker testing with primary current injection on a breaker that has not triggered in some time is the best way to recreate the real operating conditions of a current spike.
CT ratio Test
Circuit Breaker test
Resistance Test
Primary current injection test
With timer
With binary input
with 0-6A secondary current measurement meter
6m 1000A current cable

PARAMETERS

Electrical parametersAccuracy±0.5%Power Supply(AC)220V±10%·25A, 50Hz/60Hz or
110V±10%·50A, 50Hz/60HzCurrent Output (AC)1000A·5V or 500A·10VCapacity5KVAThe current output waveform distortion≤5%Dual protectionoverload electronic protection and software protectionPrimary currentRange0-1100AResolution0.1AAccuracy<0.5%Secondary measurementRange0-6AResolution0.001AAccuracy<0.5%Current duration1000A range1000A 2-3minutes
500A3-6minutes500A range500A2-3minutesWith timerRange0.0001~999.99SResolution0.001SAccuracy<0.5%±5 wordsMechanical parametersDimensions (WxDxH) (mm)430x260x260Weight(kg)25Environmental conditionsTemperature-10°C to 40°CRelative humidity≤80%

SELECTION GUIDE

ModelACCU
RACYPrimary
currentAMMETER
(0-6A)TIMERPOWERINJECTION CURRENT TIMEDIMENSION(WxDxH)(mm)WEIGHTREMARKTEST-9010.5%0-1100AYESYES5KVA1000A: 2-3min;
500A:3-6min430x260x26025KGIntegrated structureTEST-9020.5%0-2200AYESOPTIONAL12KVA2000A:2-3min;
1000A:3-6min360x300x295 and 320x300x30035KG+15KGFission structureTEST-9030.5%0-3300AYESOPTIONAL15KVA3000A:2-3min;
1500A:3-6min380x350x360 and 340x290x42048KG+42KGFission structureTEST-9050.5%0-5500AYESOPTIONAL25KVA5000A:2-3min;
2500A:3-6min430x430x445 and 550x450x60068KG+55KGFission structure

DOWNLOAD CATALOGUE PARAMETERS

Electrical parametersAccuracy±0.5%Power Supply(AC)220V±10%·25A, 50Hz/60Hz or
110V±10%·50A, 50Hz/60HzCurrent Output (AC)1000A·5V or 500A·10VCapacity5KVAThe current output waveform distortion≤5%Dual protectionoverload electronic protection and software protectionPrimary currentRange0-1100AResolution0.1AAccuracy<0.5%Secondary measurementRange0-6AResolution0.001AAccuracy<0.5%Current duration1000A range1000A 2-3minutes
500A3-6minutes500A range500A2-3minutesWith timerRange0.0001~999.99SResolution0.001SAccuracy<0.5%±5 wordsMechanical parametersDimensions (WxDxH) (mm)430x260x260Weight(kg)25Environmental conditionsTemperature-10°C to 40°CRelative humidity≤80%

SELECTION GUIDE

ModelACCU
RACYPrimary
currentAMMETER
(0-6A)TIMERPOWERINJECTION CURRENT TIMEDIMENSION(WxDxH)(mm)WEIGHTREMARKTEST-9010.5%0-1100AYESYES5KVA1000A: 2-3min;
500A:3-6min430x260x26025KGIntegrated structureTEST-9020.5%0-2200AYESOPTIONAL12KVA2000A:2-3min;
1000A:3-6min360x300x295 and 320x300x30035KG+15KGFission structureTEST-9030.5%0-3300AYESOPTIONAL15KVA3000A:2-3min;
1500A:3-6min380x350x360 and 340x290x42048KG+42KGFission structureTEST-9050.5%0-5500AYESOPTIONAL25KVA5000A:2-3min;
2500A:3-6min430x430x445 and 550x450x60068KG+55KGFission structure

PHOTO