Fireproof Suit, Fire Protection Suit, Firefighter Suit manufacturer / supplier in China, offering Protective Apparel, Fire Retardant Coverall, Manufacturer for Fire Fighter Aluminum Foil Thermal Insulation Clothing, Fire Fighter Protective Rescue Gum Boots and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $1450.00/ Piece |
Local Area: | Jiujiang, Jiangxi, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T |
Application: | Professional Equipment |
---|---|
Using Field: | Air |
Suitable for: | All |
This product adopts the knapsack structure, using a single 9L gas cylinder, equipped with the pressure flat vision device and a half ball type full cover. Respirator overall accord with human body engineering design, reasonable structure, safety performance is high, the operation is convenient, has a wide field of vision, air supply economic, functional and practical, and the advantages of stable performance, for all kinds of poison gas or anoxic environment in high-risk operations personnel.
Air respirator cylinders can be used for up to 90 minutes. In the use of breathing apparatus, please economize on gas, the exhalation frequency is controlled about 10-15 times/min.
Please read this manual carefully before using the product.
Part 2:Use for
Positive pressure fire air breathing apparatus is mainly used for fire officers and soldiers in the fire fighting or rescue to prevent inhaling harmful gases, smoke harmful pollutants, suspended in the air, or used in anaerobic environment. The respirator cannot be used underwater.
Part 3:Main structure
The respirator consists of five parts: cylinder assembly, pressure reducer assembly, full cover assembly, supply valve assembly, and back - back assembly, with a kit, receiving bag and equipment box.
Main Performance
Num.Testing programTesting result1Air tightness of the whole machine (MPa)the pressure indicator value decline 0MPa in 1 min.2weight12.5kg3Dynamic respiratory resistance
(Pa)Cylinder pressure 300MPA~2MPa, Respiration rate 40x2.5L/minPositive pressure is maintained throughout the hood.
Suction resistance:460Pa
Exhalation resistance:684PaCylinder pressure 2MPA~1MPa, Respiration rate 20x2L/minmaintained throughout the hood.
Suction resistance:400Pa
Exhalation resistance:527Pa4Static pressure (Pa)257Pa5Pneumatic alarmAlarm pressure(MPa)5.5Time of Duration(s)The continuous sound time lasted more than 15s with the sound intensity of 90dB (A).Average gas consumption(L/min)4.3