Pure sine wave high frequency ture online UPS 6kVA-20kVA
Application:
EX Series 6kVA~20kVA High frequency online UPS is specially designed for servers, data-center critical network devices, sensitive electronic equipment, telecom, bank, hospital, bureau, traffic, public security, Army and so on.
Key Features:
Large blue LCD digital display shows Detailed Real-Time UPS Status and parameters.
Output Voltage, Frequency parameter and bypass function can be set via the display.
Advanced MCU microprocessor control technology and DSP technology, ensure long life reliability.
Wide input voltage range, Zero transfer time
True online double conversion technology.
N+X Parallel Redundancy
Excellent Protection against over voltage, over load, over current, over charge and so on.
Input L and N lines reverse wiring detection, Auto start when AC back.
DC start function, Input PFC revise function.
Humanization bypass output, can be adjustable.
Smart RS232 communication with monitoring software
Intelligent slot available for AS-400 Dry contact and SNMP card Remote control
Available to work with generators.
Lightning, surge, short circuit, Network/fax/modem surge protection
Specification:
MODELEX6KEX10KEX6KLEX10KLCapacityVA/W6000VA/4800W10KVA/8000W6000VA/4800W10KVA/8000WInputNominal Voltage208/220/230/240VACVoltage Range120~275VACFrequency Range50/60Hz (Adjustable); 50Hz:46~54Hz ; 60Hz:56~64HzPhaseSingle phase with GroundPower Factor≥0.97OutputVoltage208/220/230/240*(1±1%) VACFrequency50/60Hz (Adjustable); 50Hz AC Mode: Follow AC, Battery Mode: 50Hz (1±0.2%) / 60Hz AC Mode: Follow AC, Battery Mode: 60Hz (1±0.2%)Wave FormPure sine WavePower Factor0.8Harmonic Distortion≤2% (Linear load); ≤6% (Non-Linear load)Overload CapacityLoad<105% work consistant; 105%≤load<125% 1min; 125%≤load<150% 30secCurrent Crest Ratio3∶1ConnectionsTerminal blockEfficiencyBattery Mode87%AC Mode88%BatteryTypeSealed free maintenance lead acid batteryNominal DC VoltageBuilt in batteries 12V7.0AH192 VDCQuantity16 PCSBack-up Time(Full load)≥4minutes≥3minutesDepends on requested Back-up timeRecharge Time7 hours to 90%Depends on capacity of external battery bankCharge Current(Max)1.0 A4.5ACharge Voltage219.5Vdc±1%BypassAutomatic TransferOn overload and UPS failureTransfer Time ZeroIndicatorsLCD DisplayUPS status, I/P&O/P voltage&frequency,Battery voltage, Battery capacity, Loading, Fault codeAudible Alarm Bypass, battery mode, Battery low, Overload, FaultAcoustic NoiseAt 1 Meter Distance<55dBCommunicationsIntelligent RS232 serial portWindows 98/NT/2000/XP/3000, Linux, Sun network , IBM Aix, Compaq True64 SGI IRIX, FreeBSD, HP-UX, MACSNMP (Optional)Power management from SNMP manager and web browserUSB (Optional)Windows family software and Mac OSEnvironmentalOperating Temperature0~40ºCOperating Humidity20-90% (No condensation )WeightNet weight (kgs)5960.52021.5UPS DimensionL*W*H (mm)500*248*616500*240*490