Face Mask, Mask, Protect Mask manufacturer / supplier in China, offering 3mm Thick Acrylic Material or PC Material Protect Face Mask Mslptm01, Medical Ce Certified 15 Inch Display Ultrasound Machine Mslpu75, Mslpu76 Portable Ultrasound Black and White Ultrasound Machine with Good Quality and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $100.00/ Piece |
Local Area: | Guangzhou, Guangdong, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, D/P, PayPal, WesternUnion, MoneyGram |
Classification: | Poct Analyzer |
---|---|
Type: | Poct Analyzer |
Certification: | CE, EEC, MSDS, ISO13485 |
High Quality Quantitative Immunoassay Analyzer FIA meter immmno assay POCT Fluorescence MSLIF16
Product descriptions
MSLIF16 Fluorescence Immunoassay Analyzer (hereinafter referred to the analyzer or instrument) consists of a fluorescence immunoassay analyzer, an AC adapter, and the matched test cassette.
The analyzer is a portable medical diagnosis instrument, which is used to measure the content of biomarkers in human whole blood,serum or plasma.
The test result can be used as an aid in clinical diagnosis and prognosis. The matched test cassette should be used , if does not match, the measured results may be incorrect.
Fluorescence immunoassay is a method to use trivalent rare earth ions as tracers to label protein, polypeptide, hormone, antibody,nucleic acid probe or cells.
After reaction, use analyzer to measure the fluorescence intensity in product, and then base on the ratio of fluorescence intensity to relative fluorescence intensity to determine the concentration of analyte in the reaction system, so as to achieve the purpose of sample determination.
Performance specification
Accuracy: In this analyzer, the relative deviation of the measurement results in tests should be less than or equal to ±15%.
Stability: Turn on an analyzer that can work at stable working status, then use it to test result at the initial stage. Compared the initial result with those tested 4hour and 8hour later, the relative bias should be no more than ±10%.
Repeatability: CV≤10%
Linear correlation coefficient: r≥0.9700
Power supply100-240 volts alternating current (VAC), at either 50 or 60 hertz(Hz), 2.0A, instrument input 12 volts direct current (VDC),
rated power 36VA.External connection methodnetwork cable, USB cable (less than 3 meters)External communication methodUSBOptical performance:Excitation spectrum: 365nm Receiving spectrum: Central wavelength 613nmStorage capacity500000 patient recordsDisplay mode7 inch touch screenIndicator status:Running indicator: Green (This indicator turns green in the process of testing )
Power indicator: GreenEnvironment conditionsTemperature:10ºC~30ºC
Relative humidity:≤70%
Altitude: not more than 2000 meters
Indoor / outdoor use: For indoor use only.
Power voltage fluctuation should not exceed ± 10% of nominal voltage.
Transient overvoltage category (overvoltage category) II class
Pollution level: 2 level