Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
OEM, ODM
Terms of Payment:
T/T, PayPal, WesternUnion
Main Markets:
North America, Eastern Europe, Southeast Asia, Africa, Mid East
OEM/ODM Service
Sample Available

Corona Virus, Corona Virus Mask, Corona Virus Protection manufacturer / supplier in China, offering Corona Virus Mask/Anti Virus Mask/Disposable 3 Layers of Non-Woven in Stock, Sp-400 Medical Single Channel Syringe Pump Infusion Pump for Hospital, Veterinary Automatic Cheap Electric Infusion Pump Medical Machine IP-100 and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Supply Disposable Medical Supplies China Rapid Diagnostic Test Infectious Disease Test Kits Torch Igg Igm Toxo Malaria Typhoid

China Rapid Diagnostic Test Infectious Disease Test Kits Torch Igg Igm Toxo Malaria Typhoid

Get Latest Price
Min. Order / Reference FOB Price
5000 Piece US $0.30/ Piece
Local Area: Nanjing, Jiangsu, China
R&D Capacity: OEM, ODM, Other
Payment Terms: T/T, PayPal, WesternUnion
Type: Torch Rapid Test
Material: Plastic
Quality Guarantee Period: Two Years
TOXO/Rubella/CMV/HSV 5 in 1 Torch IgM Combo Test Kit

Specification:
*Toxo: A statistical comparison for IgM was made between the results yielding a

clinical relative sensitivity: 98.2%, relative specificity: 99.2%, overall agreement: 98.9%. A statistical comparison for IgG was made between the results yielding a clinical relative sensitivity: 98.3%, relative specificity: 99.6%, overall agreement: 99.2%.

*Rubella: A statistical comparison for IgM was made between the results yielding a

clinical relative sensitivity: 96.8%, relative specificity: 98.0%, overall agreement: 97.6%. A statistical comparison for IgG was made between the results yielding a clinical relative sensitivity: 97.4%, relative specificity: 98.5%, overall agreement: 98.1%.

*CMV: A statistical comparison for IgM was made between the results yielding a

clinical relative sensitivity: 96.7%, relative specificity: 98.3%, overall agreement: 97.7%. A statistical comparison for IgG was made between the results yielding a clinical relative sensitivity: 97.4%, relative specificity: 98.2%, overall agreement: 97.9%.

*HSV1/2: A statistical comparison for IgM was made between the results yielding a

clinical relative sensitivity: 97.8%, relative specificity: 98.9%, overall agreement: 98.5%. A statistical comparison for IgG was made between the results yielding a clinical relative sensitivity: 97.7%, relative specificity: 98.3%, overall agreement: 98.1%.