Medical Operating Theatre Pendant, Pendant, Fashion Jewelry manufacturer / supplier in China, offering High Quality in Economical Price! ! Medical Gas Pendant (THR-MP580), Hospital Rise-and-Fall Transport Stretcher Cart (THR-5B), Luxurious Five Function Electric ICU Bed (THR-EB5201) and so on.
Min. Order / Reference FOB Price | |
---|---|
1 Piece | US $289.00/ Piece |
Local Area: | Jian, Jiangxi, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Type: | Infusion Pump |
---|---|
Certification: | CE, ISO13485 |
Group: | Adult |
Unique double occlusion detection to ensure overall detection of IV set
Rate Mode,Time Mode,Body Weight Mode and Drug Library for wider range of applications
Automatic door design,easy to operate
Stackable freely,newly-added online mode,more convenient for clinical applications
Independent WIFI module,support wireless communication
Product DescriptionSPECIFICATION ( Approved reliable peristaltic infusion pump )
Syringes
10, 20, 30, 50 mL of calibrated syringes
Flow rate
0.1 - 1500 mL/h
(specified value 0.1 999.9 mL/h, 0.1 mL/h step)
(specified value 1000 mL/h or above, 1mL/h step)
50 mL syringe
0.1 900 mL/h (0.1 mL/h step)
30 mL syringe
0.1 600 mL/h (0.1 mL/h step)
20 mL syringe
0.1 400 mL/h (0.1 mL/h step)
10 mL syringe
Purge rate
1500 mL/h
50 mL syringe
900 mL/h
30 mL syringe
600 mL/h
20 mL syringe
400 mL/h
10 mL syringe
Accuracy of flow rate
(Nominal value)
Accuracy including syringe: within ±2%
Mechanical accuracy: within ±1%
Display range of volume delivered
0.19999 mL
(0.1 999.9 mL, 0.1 mL step)
(1000 9999 mL, 1 mL step)
Setting of delivery limit
0.19999 mL
(0.1 999.9 mL, 0.1 mL step)
(1000 9999 mL, 1 mL step)
Occlusion detection pressure
H: 800±200 mmHg (106.7±26.7 kPa) or 1.09±0.27 kgf/cm2
C: 500±100 mmHg (66.7±13.3 kPa) or 0.68±0.13 kgf/cm2
L: 300±100 mmHg (40.7±13.3 kPa) or 0.41±0.13 kgf/cm2
Alarms
Occlusion, Nearly empty, Finish, Syringe dislocated, Plunger/Clutch disengaged, Battery low, Battery exhausted, Power cable disconnected, Flow rate over limit, Volume over limit, System error, Non-operation time over
Power
AC110~220V ±10%, 50~60 Hz ±1 Hz
Inner NiMH battery: DC12 V
Continuous operation time of battery: over 6 hours for one channel, over 4 hours for dual channel when battery is recharged for 12 hours, at flow rate of 5 mL/h.
Operation conditions
Ambient temperature: 5 to 40 , Relative humidity: 20% to 80%
Storage conditions
Ambient temperature: -40 to 55 , Relative humidity: ≤ 95%
Electric shock protection/class
Class I and internal power supply: Type CF, Continuous operation
Water proof level
IPX4
Dimension
354mm (Width)x190mm (Height)x128mm (Depth)