Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Power Transmission & Transformer Instrument Transformer China Resin Cast 0.5 Fs5 Open Type 5p20 Protection Current Transformer 5A

China Resin Cast 0.5 Fs5 Open Type 5p20 Protection Current Transformer 5A

Get Latest Price
Min. Order / Reference FOB Price
10 Piece US $150.00/ Piece
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Application: Instrument, Protection Current Transformer
Type: Current Transformer
Phase: Single
LZCK322-10 Epoxy Resin Cast 0.5 FS5 Open Type 5P20 Protection Current Transformer 5A

LZCK322-10 Resin Cast 0.5 FS5 Open Type 5P20 Protection Current Transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.The transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.

P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).
Applications
Energy meter
Power meter
Power factor meter
Ammeter
Power monitor
Distribution power transformer monitor
Reative power compensation device

Parameters

Technical parametersStandardsIEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006Rated primary current30-600ARated load≤10VARated frequency50Hz or 60HzRated secondary current5A or 1ARated short-time thermal current40kA, 1SRated continuous thermal current120%I1nSecondary winding power-frequency voltage3kV, 1minInstrument security factorFS≤10Mechanical parametersDimensions (WxDxH) (mm)φ50xφ110x52Weight (kg)1.6Operating conditionsOperating temperature-35°C to +55°CDaily average temp<+40°CAltitude<3500 metersConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

Technical data

TypeLZCK322-10LZCK322-10PurposeMeasuring current transformerProtection current transformerRatioAccuracy class and rated load(VA)Accuracy class and rated load(VA)I1/I20.51310P1510P1010P530/1 11.550/1 12 1.2575/1 1.52.5 12100/122.53 1.52.5200/12.5 1.252.5 300/13.75 1.252.5 400/17.5 1.252.5 500/110 1.253 600/110 1.53 50/5 2.575/5 2.5100/52.5 200/53.75 300/55 400/57.52.5 500/57.52.5 600/5103.75

Selection guide

ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proofLZCK-55100-1500A≤10VAφ55180x138x522PC IP65LMCK185-10300-3000A≤25VAφ185350x283x554.5PC IP65LZCK310-10300-600A≤10VAφ50φ50 x φ110 x 321Resinsilicon case (option)LZCK322-1030-600A≤10VAφ50φ50 x φ110 x 521.6Resinsilicon case (option)LZCK350-1020-600A≤25VAφ50φ50 x φ110 x 1053.1Resinsilicon case (option)LZCG530-1030-600A≤20VAφ45φ45 x φ120 x 652.1Resinsilicon case (option)

Photos