Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Medical Device (Anesthesia System, Ventilator, CPAP System, Nitrous Oxide Sedation System, ..
Establishment:
2008
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, D/P, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, Australia, Domestic
OEM/ODM Service
Sample Available

Medical Equipment, Hospital Equipment, Machine manufacturer / supplier in China, offering Sleep Therapy System Bipap S9600 Home-Use Auto-Bipap, ICU CCU NICU Hospital Ventilator/ Medical ICU Ventilator Machine S1600, Hospital ICU /Medical Mobile Ambulance Ventilator S1600 and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Surgical Equipment China S6600 High-Technology ISO Ce Medical Anesthesia Machine

China S6600 High-Technology ISO Ce Medical Anesthesia Machine

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $10000.00/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, WesternUnion
Type: Anaesthesia Machine
Kind: Gynaecology
Certification: CE, ISO13485
S6600 high-technology ISO CE medical anesthesia machine
Configuration

NO.Items* Including ★optional1Ventilation modesManual* (V-CMV)IPPV* (P-CMV)PCV* (P-S1MV)(V-S1MV)* PSV* PRVC* 2Monitoring ParametersTidal Volume* Minute Volume* PEEP* Airway pressure* Respiratory frequency* I:E* Resistance* Compliance* Oxygen concentration* 3WaveformP-T* F-T* V-T* Lung function loop* ETCO2 waveform* 4FunctionAG monitoring★ETCO2* AGSS★Electronic monitoring gas source pressure* Mechanical/Electronic rapid oxygen* ACGO* Assist air supply/oxygen supply* Built-in battery*

Technical Specification
2.1 Adjusting Parameter
Tidal Volume:10mL~1500mL;
Inspiration pressure: 1cmH2O;
Pressure support:3cmH2O~50cmH2O;
Pressure limit: 10cmH2O~100cmH2O;
PEEP: 0cmH2O~30cmH2O;
Respiration frequency:4bpm~100bpm;
Inspiration apnea: OFF, 5%~60%;
I:E:4:1~1:10;
Inspiration time: 0.2s~5s;
Trigger:5%~95%;
SIMV frequency:4bpm~60bpm;
Pressure trigger: -1cmH2O~-20cmH2O;
Flow trigger: 0.3 L/min,1L/min~15L/min;
Rise time:0s~2s;
2.2 Monitoring parameter
Tidal volume:0mL~2500mL;
Minute volume:0L/min~100L/min;
Respiration frequency:0bpm~120bpm;
Oxygen concentration:15%~100%(V/V)
Airway pressure:-20cmH2O~100cmH2O;
Inspiration platform pressure:0cmH2O~100cmH2O;
PEEP:0cmH2O~70cmH2O;
I:E:4:1~1:10;
Resistance:0 cmH2O/(L/s)~250 cmH2O/(L/s);
Compliance:0 ml/cmH2O~250 ml/cmH2O;
AG(optional)
CO2:0%~15%(V/V);
N2O:0%~100%(V/V);
Enflurane,Isoflurane:0%~8%(V/V);
Sevoflurane:0%~10%(V/V);
2.3 Alarm
VT UPPER LIMIT:5mL~2000mL;
VT LOWER LIMIT:0mL~1595mL;
MV upper limit:0.1L/min~100L/min;
MV lower limit:0.0L/min~99.9L/min;
Respiration frequency upper limit:2bpm~100bpm;
Respiration frequency lower limit:0bpm~98 bpm;
FIO2 upper limit:20%~100%;
FIO2 lower limit:18%~98%;
Airway pressure upper limit:2cmH2O~100cmH2O;
Airway pressure lower limit:0cmH2O~98cmH2O;
Apnea:20s~40s.
Oxygen concentration never lower than 25% when N2O start
2.4 Testing
Automatic leakage compensation testing.
Patient circuit leakage compensation and automatic compliance compensation.
Patient monitor and AG monitor can be equipped.
Manual ventilator, mechanical ventilation and standby.
Waveform:P-T, F-T, V-T, Lung function loop, ETCO2, Anesthesia gas, oxygen concentration, N2O concentration.
Self-testing visible
Alarming visible
ACGO function
2.5 Battery working
There are two battery inside, use one of them can last long for no less than 60 mins, when use two, it can last long for no less than 120 mins.