Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Constant Temperature Water Bath, Water Bath, Electronic Water Bath manufacturer / supplier in China, offering Constant Temperature Water Bath, Re-3000 Series 3L Rotary Evaporator, Re-2000b Digital Display Small Size Rotary Evaporator and so on.

1
    YRS
General Supplier

China SPH-300D Orbital Shaker

Get Latest Price
Min. Order / Reference FOB Price
10 Piece Contact Supplier
Local Area: Xian, Shaanxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Certification: ISO
Application: Lab
Voltage: 220V, 50Hz/60Hz.
Increasing the shaking eccentricity is more effective than increasing the rotation speed to improve oxygen supply quantity
Model: SPH-300D
Control Mode: PID(Microcomputer environmental scanning micro-process chip), Display Mode: LCD (large screen liquid-crystal display), Cycle mode: High-speed cycle mode, Shaking mode: Revolution, Driving mode: Single axis balance unit/three-dimensional balance unit, Environmental requirement: Temperature 5-50degree, Humidity: 20%-90%, Rotation frequency range: 50-300rpm, Rotation precision: ± 1rpm, Shaking amplitude: D: 50mm, Shaking panel size: 550x500mm, Exterior size/mm: 550x350x350mm, Power: 70W. Voltage: 220V, 50Hz/60Hz.
Standard Conical: 24X250ml, Max: 24X250ml, 15X500ml, 12X1000ml.
Increasing the shaking eccentricity is more effective than increasing the rotation speed to improve oxygen "supply quantity" during culturing period, and to increase "dissolved oxygen" in the inoculum. For example, in an experiment where 50ml culture medium is placed in a 500ml triangle flask, if a 25mm eccentricity shaking table with 220-250rpm is used, the rotation liquid level of the culture medium may be 6-6.2cm high. This then forms a lamella along the flask perimeter of the inoculum, greatly increasing the contact area between the gas and liquid and accelerates O2 "ingestion" of the culture medium from the air and removal of CO2. When the eccentricity is 13mm with 300rpm, the rotation liquid level of the culture medium will be only 4-4.2cm high, while at 350rpm, it is about 5 cm high. Therefore, when too little eccentricity is used to culture microbions, and decreased filling quantity and excess rotation speeds are used to improve oxygen "ingestion" speed, the abuse results in insufficient filling quantity. If culture time is longer, water volatility in the culture medium will be too large, causing excess viscidity of the culture medium and dissolved oxygen will decline. It is very difficult to increase rotation speeds very high (above 300rpm) in order to increase "oxygen ingestion" speed. Therefore, a large capacity flask shaker thoroughly solves this difficult problem.