Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Particle Size Analyzer, Image Particle Analyzer, Online Particle Size Analyzer, Nano ..
Establishment:
2005
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T, D/P, PayPal, WesternUnion
Main Markets:
Europe, Southeast Asia, Middle East, Others
OEM/ODM Service
Sample Available

Laser Particle Size Analyzer, Particle Size Analyzer, Particle Size manufacturer / supplier in China, offering Dry Wet Dispersion System Winner2308A Intelligent Laser Diffraction Particle Size Analyzer, Winner3008A Intelligent Laser Particle Size Analyzer, Particle Sizer and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Other Instruments & Meters China Silicon Powder Particle Size Analyzer

China Silicon Powder Particle Size Analyzer

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $11999.00/ Piece
Local Area: Jinan, Shandong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, D/P, PayPal, WesternUnion
Measuring Theory: Laser Diffraction
Measuring Range: 0.1-300 Micron
Dispersion System: Wet Dispersion
Winner 2000ZDE Intelligent Laser Particle Size Analyzer

Overview:

Winner2000ZDE intelligent laser particle size analyzer, perform auto test, auto alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion, auto cleaning etc., really realize one-key operation. It adopt full built-in sampling system, effectively prevents large particles sedimentation problems in the circulation pipeline, ensure good accuracy. It adopts comprehensive Laser diffraction particle size measurement principle with highly sensitive ring photoelectric detector improving the test accuracy greatly, Original designed unconstrained free fitting software technology, a true reflection of the particle size distribution, to ensure truth and accuracy of the test results. Therefore especially suits the laboratories of enterprises, colleges and universities and research institutes to use.
Main Specifications:

Model NameWinner2000ZDEStandardISO13320-1:1999, GB/T19077.1-2008, Q/JWN001-2009PrincipleMIE scattering principleMeasuring Range0.1μm-300μmChannels Number39 PCSAccuracy error<1%( CRM D50 )Repeatability error<1%( CRM D50 )Light sourceHigh performance He-Ne Laser (λ= 632.8nm, P>2MW)
Lifetime>25000hour
Dispersion
MethodUltrasonicFrequency:40KHzPower:50W,Time: ≥1S StirRevolutions Speed: 0-3000RPM (Adjustable)CirculateRated Flow:8L/min Rated Power:10WSample PoolVolume:350mLMicro-
Sample PoolVolume: 10mL ( Available)Operation ModeFull automatic and manual control, freely chooseOutput parameterD10,D50,D90,D100,S/V referent parametersOptical Calibration SystemFull automaticTest Speed<2mins for each timeVolumeL88cmxW39cmxH46cm Net Weight41Kg


2. Main Features:

1,Advanced design of light path:
A patented technique of Fourier transform of converging light released the scattered light at large-scattering-angles from the restriction of the aperture of the Fourier lens. The focal length is reduced to enhance the resolution of the instrument, and ring shaped of multi-element silicon photo-diode ensure gathering all the light signals of particles, highly improve the resolution.

2,Built-in dispersion units:
We carefully aligned the stirring set-up, the ultrasonic dispersing unit and the sample circulation pipes, and fixed them inside the instrument. Such a built-in design effectively prevents the inhomogeneous dispersion and sedimentation of big particles, which can be observed in the designs that these dispersing units are separated from the instruments, where the sample circulation pipes are therefore too long, The sample will be sufficiently dispersed.

3,Unconstrained fitting techniques:
The particle analysis software uses a unique unconstrained data fitting technique that we developed to obtain data of real particle size distribution, this is particularly important for researchers.

4,Micro sample chamber (optional):
The capacity of the sample chamber is as small as only 10ml. This helps with measuring expensive/precious samples, or samples difficult to be dispersed within medium.

5,Modern measurement control:(Intelligent SOP Operation)
Users can perform all measurement procedures by simply operating on the PC and have ideal results in a very short time.

6,User-friendly Operation:
manual mode and the automatic mode, freely choose, to measure according to the sample features. In some conditions (e.g. the sample have unknown features or there are special requirements for the measurements), users can make a test measurement in the manual mode first, and after having an idea of the sample features and the measurement conditions, measure the samples in the automatic mode.

7,Fully automatic light path alignment:
A precise four phase hybrid stepping motor automatically aligns the optical path and can adjust it at any moment, precision is up to 0.1um, This releases users from manual adjusting the optical path and improved accuracy and stability of the measurement results.

8,Quick measurements:
set " automatic" mode, all operation procedures are performed automatically,automatic water supply, automatic ultrasonic sample, stirring, circulation,background testing, sample testing,analysis , draining and cleaning, which significantly reduces the time for measurements, the full process only take 2 minutes.

9,Data analysis:
Errors in the data are rejected and the measurement results are automatically processed. Manual data processing is not necessary and the output is more standard.

3. Software Function
1, Analysis Mode
Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc. meet different demands of particle size statistic in different industries.
2,Statistic Method
Volume Distribution, Quantity Distribution
3,Statistic Comparison
Statistic Several Testing Results to compare and analyze
Get difference by compare test result of different batches of samples, samples before and after processing, and different time.
Have great practical significance to industrial raw materials quality control
4,User-defined Analysis
Figure out percentage according to the particle size
Figure out particle size according to the percentage
Figure out percentage according to the particle size range
Meet demands of representation of particle test in different industries.
5,Test Report
Word, Excel,Photo( Bmp), Text etc.
6,Multiple language Support
Chinese&English (Others are available)
7,Intelligent Operation Mode
Automatically control water inflow, dispersion,test and analysis.
Better Repeatability after remove human-factor
4. Laser Particle Size Analyzer Application Field:

1.Non-metallic powders such as calcium carbonate, talcum powder, kaolin, zirconium silicate, wollastonite, graphite, silica powder, tourmaline, mica, barite, plaster, bentonite, diamond, quartz, diatomite, feldspar, calamite,clay, garnet, vermiculite, Titanium white power, etc.
2. metallic powder such as aluminum powder, iron powder, magnesium powder, molybdenum powder, copper powder, zinc powder, other rare metal power and varied alloy powder, etc.
3. Pharmaceutical, agricultural pesticide, grinding particle, foodstuff, scientific research, teaching, cement, ceramic, glass, chemical industry, military industry, soil, toner,pigment, oil exploration, geological analysis, river silt and electronic particle, etc.

5. Winner2000ZDE Laser Particle Size Analyzer Patents Technology:
Optical bench design is protected by patent No.- ZL 2014 2 0378380.8, Three dimensional-optical bench alignment system is protected by patent No.- ZL 2013 2 0835882.4.MIE scattering principle application patent is protected by patent No.- ZL 2013 2 0812021.4.Wet circulation installation is protected by patent No.-ZL2010 2 0593526.2.
6. Test Report
Report Interpretation
D10=X, means ≤X particle size's particle volume content occupy 10% of all the particles.D50=Y, means ≤Y particle size's particle volume content occupy 50% of all the particles.D90=Z, means ≤Z particle size's particle volume content occupy 90% of all the particles.DAV: Average particle size of particles groupS/V: Specific surface area, surface to volume ratio/ Surface area per unit volumeD[3,2] Weighted average surface areaD[4,3] Volume weighted averageParticle Size Analysis Chart illustration:The transverse is the particle size value, and the value is logarithmic distribution.The left column is the volume of the cumulative percentage, the corresponding curve is upward trend.The right column is the percentage of the volume of a certain interval, corresponding to the histogram or undulating curve.The data list is corresponding to the test result of analysis chart.