Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Surge Protector, Lightning Arrester, Signal SPD manufacturer / supplier in China, offering 1000Mbps RJ45 Gigabit Poe Outdoor Lightning Protector, 100Mbps RJ45 Data Cat5 Single Channel Network SPD Surge Protector, Power Surge Protector Box/SPD Box/Instrument Protection Box and so on.

1
    YRS
General Supplier
Supplier Homepage Computer Products Network Hardware & Parts Communication Module China Single Channel RJ45 Data SPD 100Mbps Ethernet Surge Lightning Protector

China Single Channel RJ45 Data SPD 100Mbps Ethernet Surge Lightning Protector

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $15.00/ Pieces
Local Area: Shenzhen, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Usage: Computer, Workstation, Server, Laptop
Type: Wireless
Support Network: Ethernet
Single Channel RJ45 Data SPD 100Mbps Ethernet Surge Lightning Protector
Model: SN-RJ45

Thank you for choosing Cat5 Surge Protector SN-RJ45. The model is designed to protect high-speed communication network from lightning over-voltage, transient over-voltage and static discharge. The protector implements multi-level protection circuit with advanced manufacturing process, and has excellent performance on discharge current, limiting voltage, response time, stability and over-all reliability.FEATURES:
Multi. Protection circuits, Gas-Tube+ TVS technology
Dual protection in Common module and different module
TVS array technology, low capacitance
Multi-Strike Capability
TECHNICAL PARAMETER: ModelSN-RJ45Electrical ParameterMax. continuous operating voltage Uc6VNominal discharge current(8/20µs)In2.5kAMax. discharge current (8/20µs)Imax5kALimiting voltage (10/700µs) Up Line-line25VLine-ground500VAdapt transmission rate100MbpsInsertion loss Ae0.5dBProtection line1/2 3/6Response time Ta1nsInterface formRJ45Mechanical characteristics Dimension100(L) x37(W) x28(H)mmWeight per unit100gIP CodeIP20Working conditionsTemperature: -40 to 80ºC, Relative humidity: ≤95%Standards ComplianceCE, FCC, RoHS,ISO9001


INSTALLATION AND MAINTENANCE
a) The SPD should be connected in series between the protected device and the signal/power transmission channel.
b)The input terminal (IN) of the SPD should connect to the signal/power transmission channel, and the output terminal (OUT) of the SPD should connect to the protected device.
c) Connect earthing wire of the SPD to earthing bus-bar of the lightning protection system of the room or building.
No special duty needs to be carried out for maintenance. When problem arises and the SPD is suspected, check the system with SPD taken out of circuit. Should system recover, the SPD shall be regarded as a damaged unit and must be replaced immediately.