Business Type:
Trading Company
Business Range:
Medical Equipment, Anesthesia, Monitor, X-Ray, Lab
Establishment:
2003
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T
Main Markets:
South America, Europe, Southeast Asia, Middle East, Africa
OEM/ODM Service
Sample Available

Ventilator Machine, Ventilator, ICU Ventilator Machine manufacturer / supplier in China, offering Ventilator Machine with Air Compressor for ICU, Medical IV Drug Ambulance Infusion Pump Machine with Drop Sensor, Movable Stainless Steel Cuna Lit Bebe Hospital Baby Cot Infant Crib Bed and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Surgical Equipment China Surgical Equipment Anesthesia Workstation Anesthesia Machine

China Surgical Equipment Anesthesia Workstation Anesthesia Machine

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $11000.00/ Piece
Local Area: Hanzhong, Shaanxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Type: Anaesthesia Machine
Certification: CE, ISO13485
O2 Flush: 35~75L/Min

Anesthesia Workstation Anesthesia Machine
1.Anesthesia Unit
2.Anesthesia Equipment
3.Anesthestic Machine
4. Anesthesia Machine With Ventilator
Specifications:
Flow:O2 0.05~1L/min;1~10L/min


N2O 0.05~1L/min;1~10L/min


AIR 0.2~1L/min;1~12L/min


ORC O2≥25%

O2 flush35~75L/min

Oxygen deficiency alarm and N2O cut-offWhen O2≤0.2Mpa, audible alarm occurs and lasts for at least 7 seconds

When O2≤0.14Mpa, N2O flow decreases correspondingly

When O2≤0.04Mpa, N2O flow is cut off

Integrated breathing circle systemAPL adjustment range: 0.5~7kPa

CO2 absorber capcity: 1.6L

VaporizerAmbient temperature: 15~35°C

Input flow: 0.25~15L/min

Output back pressure: -10kPa~20kPa

Output concentration: 0.2%~5%(±0.2%) (Vol%)

Frequency:6~40 bmp

Tidal volume: Adult: 100~1100mL Infant: 30~150mL

I:Eratio: 1:1~1:9.9 adjustable

FlowO2 0.05~1L/min;1~10L/min N2O 0.05~1L/min;1~10L/min AIR 0.2~1L/min;1~12L/min ORC O2≥25%O2 flush35~75L/minOxygen deficiency alarm and N2O cut-offWhen O2≤0.2Mpa, audible alarm occurs and lasts for at least 7 secondsWhen O2≤0.14Mpa, N2O flow decreases correspondinglyWhen O2≤0.04Mpa, N2O flow is cut offIntegrated breathing circle systemAPL adjustment range: 0.5~7kPaCO2 absorber capcity: 1.6LVaporizerAmbient temperature: 15~35°CInput flow: 0.25~15L/minOutput back pressure: -10kPa~20kPaOutput concentration: 0.2%~5%(±0.2%) (Vol%)Frequency6~40 bmpTidal volumeAdult: 100~1100mL Infant: 30~150mLI:Eratio 1:1~1:9.9 adjustable