Air Conditioning Thermostat, Thermostat, Adjustable Thermostat manufacturer / supplier in China, offering Adjustable Air Conditioning Thermostat for Room Temperature Controls (HTW-31-F17), Wf06 Series Nest Wall Flush Install Smart AC Thermostat for Home Air Conditioner, HVAC Parts IP20 Hotel Electric Power Energy Saver with Magnetic Door Contact and so on.
Min. Order / Reference FOB Price | |
---|---|
100 Pieces | US $10.00/ Pieces |
Local Area: | Beijing, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal |
Operating Pressure10kgf/cm² (1MPa)Withstand Pressure17.5Kgf/cm² (1.75MPa)Insulation ResistenceOver 100Ω, DC500VMWithstand VoltageAC1500V/1minuteContact Point Life1000K CycleBellows Life500K CycleTemperature of FluidMax 100°C (212°F)Body Size1"(HTW-WS-25), 3/4"(HTW-WS-20),1/2"(HTW-WS-15)
Product description:1, Type: HTW-F61KB-11C
2, Pipe connector: 1 in. 11-1/2 NPT Threads
3, Switch contact: SPDT
4, Bellow pipe / blade: phosphor bronze / stainless steel
5, Blade: detachable 1", 2", 3" blades and 6" blade ( uninstalled)
6, Liquid temperature: 0~121ºC
7, Max. Liquid pressure: 1034 KPa
8, Electrical ratings: 120VAC; 208VAC; 240VAC; 277VAC
9, Full load current (A): 16.0; 8.8; 8.0
10, Transient current (A): 96.0; 52.8; 48.0
11, Non-inductive current (A): 16.0
12, other: NEMA 1 shell
1~3" blades
Required to actuate switch (m³/h)
Pipe size(in)
1
1-1/4
1-1/2
2
2-1/2
3
4
5
6
8
Min. flow
Flow increase R to B closes
1.0
1.3
1.7
3.1
4.1
6.2
14.8
28.4
43.2
85.2
Flow decrease R to Y closes
0.6
0.8
1.1
2.2
2.8
4.3
11.4
22.9
35.9
72.7
Max. flow
Flow increase R to B closes
2.0
3.0
4.4
6.6
7.8
12.0
29.1
55.6
85.2
172.6
Flow decrease R to Y closes
1.9
2.8
4.1
6.1
7.3
11.4
27.7
53.4
81.8
165.8
6" blade
Required to actuate switch(m³/h)
Pipe size(in)
4
5
6
8
Min. flow
Flow increase R to B closes
8.4
12.9
16.8
46.6
Flow decrease R to Y closes
6.1
9.3
12.3
38.6
Max. flow
Flow increase R to B closes
13.4
26.8
32.7
94.3
Flow decrease R to Y closes
17.3
25.2
30.7
90.9