Telecom Uninterruptible Power Supply 10-200Kva
1: UPS with Three Phase 380/400/415Vac or 190/208/220Vac Input/Output
2: Low Frequency UPS with IGBT inverter technology
2: Advanced digital circuit UPS Power system
3: EPO function for UPS
UPS Application
Large-medium computer data center, industrial process and other mission-critical equipment
UPS Key Features
1: DSP control
2: Double CPU control
3: Modularize
4: Battery can be sharing
5: Up to 8 units in parallel
6: Compatible with generator
7: Manual maintenance bypass
8: Wide input voltage range
9: High output power factor
10: Strong environmental adaptability
11: Advanced battery management
12: N+X parallel redundancy
13: Strong shock resistance ability
14: EPO function
15: Full protection against over-discharge, overcharge, over load
High Efficiency Strar Series HE33 10K-200KModelHE33 Series UPSCapacity (VA)10K15K20K30K40K60K80K100K120K160K200KNoninal output capacity8KW12KW16KW24KW32KW48KW64KW80KW96KW128KW160KWOperate typeDouble conversion online typeInputNominal voltage220V/380, 230/400, 240/415V Voltage Tolerance380/400/415V±25%Frequency50Hz/60Hz±5%Permitted Frequency Tolerance±2% (selectable from ±1% to 5% from the front panel)Soft start0-100% in 30" (selectable)Input power factor0.95(with input filter)Standard featuresBack Feed protection separable bypass line PhaseThree phase +N+GOutputVoltage220V/380, 230/400, 240/415V, ±1% (stable load), ±5%(active load)Frequency50/60Hz (±5%, AC mode), 50/60Hz (±1%, Battery mode)Static stability±5% in 19msDistortionLinear load <3%, non linear load<5%Power factor0.8Output wavePure sine waveCrest factor3:01Battery voltageStandard battery voltage384V432V480VFloating charge432V486V540Terminal voltage336V378V420VCharge current1A-50A (Can calculate and set according to battery configuration software)Maximum Discharge Current28425685113169225282338381507Main FunctionActive voltage change0-100%±5%Instant recover time<10msImbalance voltage<±5%,<±1%( Balance load voltage)Overload capacity125% → 10min,150% → 1minStatic switchAutomaticProtectionUPS over current, short circuit, battery low voltage, over heatCold methodCompel aeration ( temperature control mode)Noise60-65dBDisplayLED LCD displayRemote signallingVoltage-free contactsRemote commandsEPO and bypassCommunication Port (Optional)double RS232 + remote contacts + 2 communication interface slotsAlarmAlarm with buzzer and indicatorsEnvironmentTemperature: 0-40C Humidity: 0-90%*Specification are subject to change without prior notice