Business Type:
Manufacturer/Factory
Business Range:
ABC Cable, AAAC, ACSR and Aw, Acar
Establishment:
2012
R&D Capacity:
OwnBrand
Terms of Payment:
LC, T/T, PayPal, WesternUnion
Main Markets:
North America, South America, Europe, Southeast Asia, Middle East, Africa, East Asia(Japan, South Korea), Australia, Domestic
OEM/ODM Service
Sample Available

Service Drop Cable, ABC Cable, Triplex Cable manufacturer / supplier in China, offering Overhead Insulated Aerial Bundle Service Drop Triplex ABC Cable, A1/A3 Aluminum Conductor Alloy Reinforced Acar for IEC61089 Standard, Aluminum Clad Steel Wire and Aluminum Clad Steel Strand Acs and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Optical Fiber, Cable & Wire Electric Wire & Cable China Thhn Wire Copper PVC Insulation Nylon Jacket Electric Building Wire

China Thhn Wire Copper PVC Insulation Nylon Jacket Electric Building Wire

Get Latest Price
Min. Order / Reference FOB Price
1000 Meter US $5.00/ Meter
Local Area: Zhengzhou, Henan, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal, WesternUnion
Brand: Rmjt
Type: Insulated
Conductor Type: Solid or Stranded
Application: Underground, House and Building
THHN Wire Copper PVC Insulation Nylon Jacket Electric Building Wire
1.Application:
1Type TW THW THHN THWN TFF building wire is intended for general purpose applications as defined by the National Electrical Code (NEC)Type TW THW THHN THWN TFF is permitted for new construction or rewiring for 60volt applications. Applications requiring Type THHN or THWN2, the conductor is appropriate for use in wet or dry locations at temperatures not to exceed 90°C or not to exceed 75°C in oil or coolants. Applications requiring Type MTW conductor is appropriate for use in dry locations at 90°C, or not to exceed 60°C in wet locations or where exposed to oils or coolants. Applications requiring Type AWM conductor is appropriate for use at temperatures to not exceed 105°C in dry locations.
Features:
Nylon outer jacket for easy pulling. VW-1 rated 14 AWG - 8 AWG. All sizes are rated gasoline and oil-resistant II.
Jacket:
A tough, polyamide, Nylon outer covering per UL-1063 and UL-83.
2.Standard:
UL-83, UL-1063, UL-758
3.Specification:
UL 83 UL 1581

AWG/MCMmm2ConductorInsulationShealthTotal WeightSingle WireOD.PVCNylonNo.Dia.thickminminOD.Thick milsmmOD.mmmmmilmmmmmilmmmmmilmmmmkg/km161.3111.291.29150.380.51140.362.0540.12.2516.73142.0811.6261.626150.380.51140.362.38640.12.58624.53123.2912.0482.048150.380.51140.362.80840.13.00836.61105.2612.5892.589200.510.64190.483.60940.13.80958161.6770.5511.653150.380.51140.362.41340.12.61321.5142.0870.6151.845150.380.51140.362.60540.12.80525.84123.3070.7752.325150.380.51140.363.08540.13.28538.51105.2670.9782.934200.510.64190.483.95440.14.15460.8296.6371.0983.294200.510.64190.484.31450.134.57475.3488.3271.233.69300.760.9280.715.2150.135.4798.69710.4771.384.14300.760.9280.715.6650.135.92120.76613.2171.554.65300.760.9280.716.1750.136.43148.58516.6571.745.22300.760.9280.716.7460.157.04183.78421.1271.965.88401.021.1350.897.9260.158.22235.76233.5472.477.41401.021.1350.899.4560.159.75359.83161.23190.2871.435150.380.51140.362.19540.12.39516.72142.04190.371.85150.380.51140.362.6140.12.8125.35123.30190.472.35150.380.51140.363.1140.13.3138.27105.19190.592.95200.510.64190.483.9740.14.1759.8696.50190.663.3200.510.64190.484.3250.134.5873.6488.17190.743.7300.760.9280.715.2250.135.4895.16710.53190.844.2300.760.9280.715.7250.135.98120.74613.19190.944.7300.760.9280.716.2250.136.48145.02516.45191.055.25300.760.9280.716.7760.157.07180.78421.13191.195.74401.021.1350.897.7860.158.08229.38326.40191.336.45401.021.1350.898.4960.158.79280.88233.58191.57.26401.021.1350.899.360.159.6350.23142.12191.688.15501.271.38451.1410.6970.1811.05447.221/053.30191.899.14501.271.38451.1411.6870.1812.04555.152/067.07192.1210.3501.271.38451.1412.8470.1813.2687.523/084.53192.3811.6501.271.38451.1414.1470.1814.5854.274/0107.18192.6813501.271.38451.1415.5470.1815.91068.65250125.72372.0814.2601.521.67551.417.2480.217.641272.29300151.06372.2815.5601.521.67551.418.5480.218.941512.81350177.29372.4716.8601.521.67551.419.8480.220.241761.4400202.53372.6417.9601.521.67551.420.9480.221.341999.42500252.89372.9519.7601.521.67551.422.7480.223.142470.99600304.24612.5222701.781.94651.6525.5690.2326.022998.91650328.87612.6222.9701.781.94651.6526.4690.2326.923231.59750378.30612.8124.6701.781.94651.6528.1690.2328.623697.591000506.04613.2528.4701.781.94651.6531.9690.2332.424896.32

4.Other UL specification:

TW THW

TW THW
600V 60ºC
UL 83 UL 1581
Type TW and THW may be used for general purpose wiring for power and
lighting, for insulation in air, conduit, duct or other recognized raceways, in wet or dry locations.
Maximum voltage rating= 600 VMAXIMUM ConDUCTOR TEMPERATUREtypeoilwetdryTW60ºC60ºC60ºCTHW75ºC75ºC75ºCMTW*60ºC60ºC90ºC* 1AWG AND LARGER ONLY

AWG/MCMmm2ConductorConductorInsulationTotal WeightTypeSingle WireOD.PVCkg/km No.Dia.ThickmmThickminOD. mils 180.82solid11.021.02300.760.890.72.5414.82161.31solid11.291.29300.760.890.72.8120.27142.09solid11.631.63300.760.890.73.1528.6123.33solid12.062.06300.760.890.73.5841.48105.27solid12.592.59300.760.890.74.1160.9388.35solid13.263.26451.141.2215.5498.99613.33solid14.124.12601.521.671.47.16162.23421.16solid15.195.19601.521.671.48.23240.34180.82B70.3861.158300.760.890.72.67815.65161.31B70.4881.464300.760.890.72.98421.43142.08B70.6151.845300.760.890.73.36530.1123.30B70.7752.325300.760.890.73.84543.38105.26B70.9782.934300.760.890.74.45464.0288.32B71.233.69451.141.2215.97103.92613.21B71.554.65601.521.671.47.69169.62421.12B71.965.88601.521.671.48.92252.44233.54B72.477.41601.521.671.410.45379.53142.62B191.698.18802.032.111.812.24480.751/053.30B191.899.19802.032.111.813.25586.712/067.70B192.1310.34802.032.111.814.4727.523/085.24B192.3911.61802.032.111.815.67897.844/0107.18B192.6813801.521.671.416.441097.15250126.94B372.0914.2952.412.562.219.021340.08300152.39B372.2915.54952.412.562.220.361586.07350177.29B372.4716.79952.412.562.221.611825.98400202.53B372.6417.96952.412.562.222.782068.12500252.89B372.9520.04952.412.562.224.862548.31600304.24B612.52221102.792.892.527.583084.92750380.99B612.8224.641102.792.892.530.223816.91000506.04B613.2528.41102.792.892.533.985002.6


5.Package:
Packing in plastic reel, paper reel ,wooden drum or as customer's requirement.
6.Our factory:
People's Cable Group Co., Ltd. was founded in 2007, located in Zhengzhou Gongyi economic development zone. Our company has 2 factories (Zhitian factory and Zhulin factory), occupies total area of more than 300,000 square meters, with building area 230,000 square meters.
7.Certificate:
As first rank of the cable supplier in China, we have obtained CCC, ISO9001, ISO14001, OHSAS certificates, passed the SGS and BV test, and our brand "RMJT" be given China famous brand.
8.Customer Visit:
We have a professional sales team with each of them has engaged in this job for 3-10 years, so that we can provide the comprehensive and professional technology for you. With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win establish relationship!
9.Contact:
Dear friends, welcome to our store. We will provide you with china wholesale market market products, excellent service and reasonable price.Please contact us if have any questions about the product. we will answer the questions carefully.At last,I wish you a pleasant purchase.
Factory ADD:No.13th,YongDing Road, Goingyi,Zhengzhou city, Henan province, China.