Business Type:
Manufacturer/Factory
Business Range:
Access Control, Card Reader, Multi Door Access Controller, ID Card, Mifare Card
Establishment:
2002
R&D Capacity:
OEM, ODM
OEM/ODM Service
Sample Available

Magnetic Lock, Bolt Lock, Strike Lock manufacturer / supplier in China, offering 350kgs Single Door Magnetic Lock, Em/MIFARE Proximity RFID Card Reader, No Touch Exit Button and so on.

1
    YRS
General Supplier

China Two Channel Relay Timer

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $9.40/ Piece
Local Area: Beijing, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE
Application: Enterprise, Supermarket, Campus, Hospital, Parking, Warehouse, Hotel, Company, Garage, Community
[Function 1]:
Timing Pull-in: after power on, when arrived the setting time T1,the relay pull-in,
and the T1 can be adjustable between 0.1 second -270 hours, give CH1 interface a
high pulse signal(high level duration≥20ms),repeat the above function.
[Function 2]:
Timing Disconnect: after power on the relay pull-in, when arrived the setting time
T1,the relay disconnect, and the T1 can be adjustable between 0.1 second -270 hours,
give CH1 interface a high pulse signal(high level duration≥20ms),repeat the above
function.
[Function 3]:
Timing Pull-in Then Disconnect: after power on, the relay don' t pull-in, when
arrived the setting time T1 relay pull-in; when arrived the setting time T2 relay
disconnect, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give
CH1 interface a high pulse signal(high level duration≥20ms),repeat the above
function.
[Function 4]:
Timing Disconnect Then Pull-in : after power on, the relay immediately pull-in, when
arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay
pull-in, and the T1 and T2 can be adjustable between 0.1 second -270 hours, give
CH1 interface a high pulse signal(high level duration≥20ms),repeat the above
function.
[Function 5]:
Unlimited Cycle Timing Mode A: after power on, the relay don't pull-in, when arrived
the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect,
then repeat the above status, and the T1 and T2 can be adjustable between 0.1 second
-270 hours, give CH1 interface a high pulse signal(high level duration≥20ms),repeat
the above function.
[Function 6]:
Unlimited Cycle Timing Mode B: after power on, the relay immediately pull-in, when
arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay
pull-in, then repeat the above status, and the T1 and T2 can be adjustable between
0.1 second -270 hours, give CH1 interface a high pulse signal(high level duration
≥20ms),repeat the above function.
[Function 7]:
Limited Cycle Timing Mode A: after power on, the relay don't pull-in, when arrived
the setting time T1 relay pull-in; when arrived the setting time T2 relay disconnect,
then repeat the above status "NX" times, the T1 and T2 can be adjustable between
0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999,give
CH1 interface a high pulse signal(high level duration≥20ms),repeat the above
function.
[Function 8]:
Limited Cycle Timing Mode B: after power on, the relay immediately pull-in, when
arrived the setting time T1 relay disconnect; when arrived the setting time T2 relay
pull-in, then repeat the above status "NX" times, the T1 and T2 can be adjustable
between 0.1 second -9999 seconds, the cycle times "NX" can be adjustable between
1-9999, give CH1 interface a high pulse signal(high level duration≥20ms),repeat
the above function.
[Function 9]:
Self-locking Mode: give CH1 interface a high pulse signal, the relay pull-in, again
give a high pulse signal, the relay disconnect.
[Function 10]:
Trigger Mode: contain delay off function, the relay does not operate after power
on ,give CH1 interface a high pulse signal, the relay pull-in immediately, when
the high pulse signal disappeared, the relay still pull-in, when arrived the setting
time T1 relay disconnect, the T1 can be adjustable between 0 second-270 hours.
Remark: in this function, if T1 is 0 second, give CH1 connector a high pulse signal,
the relay pull-in, when the high pulse signal disappeared, the relay immediately
disconnect.
[Function 11]:
Trigger timing mode A : the relay does not operate after power on ,give CH1 connector
a high pulse signal, when arrived the timing time T1,the relay pull-in ,T1 can be
adjustable between 0.1 second -270 hours, give CH1 interface a high pulse signal
again, repeat the above function one time.
[Function 12]:
Trigger timing mode B: the relay does not operate after power on ,give CH1 interface
a high pulse signal, the relay pull-in , when arrived the timing time T1, the relay
disconnect,T1 can be adjustable between 0.1 second -270 hours, give CH1 interface
a high pulse signal again, repeat the above function one time.
[Function 13]:
Trigger timing mode C : the relay does not operate after power on ,give CH1 interface
a high pulse signal, when arrived the timing time T1,the relay pull-in ,when arrived
the timing time T2,the relay disconnect, timing time T1 and T2 can be adjustable
between 0.1 second -270 hours, give CH1 interface a high pulse signal again, repeat
the above function one time.
[Function 14]:
Trigger timing mode D: the relay does not operate after power on ,give CH1 interface
a high pulse signal, the relay pull-in immediately , when arrived the timing time
T1, the relay disconnect, when arrived the timing time T2,the relay pull-in, timing
time T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface
a high pulse signal again, repeat the above function one time.
[Function 15]:
Unlimited Cycle Timing Mode A: the relay does not operate after power on ,give CH1
connector a high pulse signal, when arrived the timing time T1,the relay pull-in ,
when arrived the timing time T2,the relay disconnect, then repeat the above status,
T1 and T2 can be adjustable between 0.1 second -270 hours, give CH1 interface a high
pulse signal again ,repeat the above function.
[Function 16]:
Unlimited Cycle Timing Mode B: the relay does not operate after power on ,give CH1
interface a high pulse signal, the relay pull-in immediately, when arrived the timing
time T1,the relay disconnect, when arrived the timing time T2,the relay pull-in,then
repeat the above status , T1 and T2 can be adjustable between 0.1 second -270 hours,
give CH1 interface a high pulse signal again ,repeat the above function.
[Function 17]:
Limited Cycle Timing Mode A: the relay does not operate after power on ,give CH1
interface a high pulse signal, when arrived the timing time T1,the relay pull-in ,
when arrived the timing time T2,the relay disconnect, then repeat the above status
"NX" times, the T1 and T2 can be adjustable between 0.1 second -9999 seconds, the
cycle times "NX" can be adjustable between 1-9999,give CH1 interface a high pulse
signal again ,repeat the above function.
[Function 18]:
Limited Cycle Timing Mode B: the relay does not operate after power on , give CH1
interface a high pulse signal, the relay pull-in immediately, when arrived the timing
time T1,the relay disconnect, when arrived the timing time T2,the relay pull-in,
then repeat the above status "NX" times, the T1 and T2 can be adjustable between
0.1 second -9999 seconds, the cycle times "NX" can be adjustable between 1-9999,give
CH1 interface a high pulse signal again ,repeat the above function.
.