Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Heating Plate, Electric Hot Plate, Cooker Hot Plate manufacturer / supplier in China, offering Factory OEM Cast Iron Cooker Plate Electric Solid Hotplate, Flexible Electric Heating Polyimide Film Heater Thermo Foil Heater, Strip Heater Stainless Steel Insulated Screw End Terminal Mica Heater and so on.

1
    YRS
General Supplier
Supplier Homepage Electrical & Electronics Heating, Refrigeration & Temperature Control Temperature Controller China Type D Hydraulic Capillary Thermostat Temperature Protector Switch

China Type D Hydraulic Capillary Thermostat Temperature Protector Switch

Get Latest Price
Min. Order / Reference FOB Price
500 Piece US $2.50/ Piece
Local Area: Huizhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: ISO9001, CE
Display Type: Mechanical Dial Knob

Type D Hydraulic Capillary Thermostat
Working Principle: When the temperature of the controlled object changes, the substance (generally liquid) in the temperature sensing part of the temperature controller will generate the corresponding physical phenomenon (volume change) of thermal expansion and cold contraction, and the capsule connected with the temperature sensing part will generate expansion or contraction. based on the principle of lever, the on-off action of switch is driven to achieve the purpose of constant temperature. The liquid expansion temperature controller has the characteristics of accurate temperature control, stable and reliable, small temperature difference between start and stop, wide range of temperature control and adjustment, and large overload current.
The thermostat shown in the picture is a kind of universal Capillary Termostat applied in a number of electrical appliances. According to the customized specifications, it could be made to control temperature from -35 deg C to +350 deg C. More technical information of this Capillary Termostat will be shown in the table below.

Features:

1.Strictly comply with UL, CE, CQC, RoHS

2.Available in a wide temperature range and differential

3.Temperature adjustable through adjusting shaft

4.Auto-reset, manual-reset, and fixed temperature design available

5.Snap-Action electric switch

6.Little magnetic interference

7.Long life usage

8.Accessories, such as knob, bezel, capillary gland kit etc. available

9."D" shaped adjusting shafts with different lengths are available according to a variety of electrical appliances
E Type Capillary Termostat

Temperature Rangeof Capillary Termostat-35°C~ +320°CGeneral Temperature Range+0°C~+40°C
+30°C~+85°C
+30°C~+90°C
+30°C~+110°C
+30°C~+185°C
+50°C~+300°C
+50°C~+320°CTemperature Differential5% of Action TemperatureLength of Capillary300mm~3000mm optionalMaterial of Capillary and Sensing BulbStainless Steel and Copper optionalDiameter of Sensing Bulb3mm,4mm,5mm,6mmElectric Rating16(3)A 250VAC~10(1.8)A 400V Wiring DiagramSingle PoleSingle Throw (SPST)
Single Pole Double Throw (SPDT)Material of TerminalBrassMounting Hole2-M4Center of Mounting Hole28mmMin. Capillary Bend Radius5mmTemperature's Rate of Change1°C/minLife100000 cycles


Using Notice:
1. When the liquid expansion capillary temperature controller leaves the factory, the regulating shaft is at the high temperature point;
2. When installing the liquid expansion temperature controller, the temperature sensing package shall be as close to the surface of the controlled temperature object as possible, or the whole temperature sensing package and the temperature measuring medium shall have good heat conduction, which can reduce the temperature error and achieve the goal of accurate temperature control. During installation, the temperature sensing package shall not be deformed to avoid affecting its performance;
3. Corrosive liquid or conductive medium enters into the liquid expansion thermostat or pollutes the thermostat surface, so as not to affect the electrical insulation performance and product function;
4. When installing the hydraulic expansion thermostat, do not press the main body with the fastening screw. M4 * 5 or M4 * 6 is the appropriate fastening screw to avoid the main body deformation and the action temperature drift;
5. Capillary tube and temperature sensing bag are vulnerable parts, which shall not be bruised, flattened or broken. The main body and the junction between the temperature sensing cylinder and capillary tube shall not be twisted within 40mm. The bending radius of capillary tube shall be greater than 5mm. The capillary tube is hollow wire. Do not bend hard or at right angles to avoid blocking the flow of liquid inside. ;
6. The main body of the liquid expansion thermostat is sealed with red paint and fixed with nuts and screws, which are carried out after the temperature characteristic test and are not allowed to be adjusted at will. Otherwise, the performance of the thermostat will be changed;
7. The maximum allowable temperature of the temperature sensing package of the liquid expansion temperature controller: H / off (maximum temperature) + 30 ºC. If the temperature value is exceeded during use, the liquid expansion temperature controller will be damaged. When the temperature limiter is reset, it can only be reset manually when the temperature of the temperature sensing cylinder is reduced by more than 50 ºC;
8. The liquid expansion temperature controller should be handled with care to avoid damaging or affecting its performance.
9. When wiring, do not bend the terminal to avoid the change of internal spring clearance.
10. The input voltage and current shall not exceed the rated electrical specification of the product.
11. Do not press the temperature sensing rod hard to deform, so as to avoid internal pressure change and affect the accuracy.