Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Landing Valve, Fire Hydrant Valve, Fire Hose Valve manufacturer / supplier in China, offering Fire Hose/Hydrant Landing Valve Oblique Type, UL Listed Brass Ball Valve for Fire Fighting, UL/FM Vertical Type Indicator Post and so on.

1
    YRS
General Supplier
Supplier Homepage Security & Protection Alarm & Security Systems Alarm China UL Listed Fire Alarm System Wall Ceiling Mounted Sounder Horn for Indoor-Use Applications Dt971r

China UL Listed Fire Alarm System Wall Ceiling Mounted Sounder Horn for Indoor-Use Applications Dt971r

Get Latest Price
Min. Order / Reference FOB Price
500 Piece US $1.00/ Piece
Local Area: Shanghai, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Signal Transmission: Wired Alarm
Working Mode: Passive
Application: Indoor
The D-TECTRON Notification Appliance series offers the most versatile and easy-to-use line of horns, strobes,
and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, Spectralert Advance can meet virtually any application requirement.
The wall-mount horns, strobes, and horn strobes include a variety of features that increase their application
versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the
back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground
faults.
The temporal tone generated by the horn portion is designed as per ANSI and NFPA72 for standard emergency
evacuation signaling requirement. The horn has the feature that can synchronize multiple horns in a complete
fire alarm system.
Feature
- Plug-in design w minimal intrusion into the back box
- Tamper-resistant construction
- Field-selectable candela settings on wall units: 20,35,50, 85,105,130
- Horn rated at 85+ dBA
- Compatible with DT951 sync module
- Listed for ceiling or wall mounting
Engineering Specifications
General
D-TECTRON series horns, strobes, and horn strobes shall mount to a standard a 4"x4" electrical box or combine the Printed Circuit Board (PCB) fixed structure. The notification appliance circuit wiring shall terminate at the universal mounting plate. D-TECTRON products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 10,35, 50, 85, 105, 130.
Strobe
The strobe shall be a D-TECTRON Model DT981R,DT981W,DT982R and DT982W to UL1638, UL 1971 and shall be approved for fire protective service.
Horn Strobe Combination
The horn strobe shall be a D-TECTRON Model DT961R,DT961W,DT962R and DT962W listed to UL1971, UL 1638, UL 464 and shall be approved for fire protective service. The LED light source offers superior performance, including low power consumption and long operating life. Figure 1 shows relative light outputs dispersion from strobes mounted on walls
Synchronization Module
The module shall be a D-TECTRON DT951 listed to UL 464 and shall be approved for fire protective service. The
module shall synchronize D-TECTRON strobes at 1 Hz and horns at temporal three. The module shall mount to a
4"x4" electrical box or combine the Printed Circuit Board (PCB) fixed structure and base using the screws provided. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones.
Installation

Wiring

Indoor use appliance

ModelColorWordingCandela ratingHorn StrobeFW961RRedFIRE/FEU50FW962RRedFIRE/FEU20, 35, 50, 85, 105, 130FW961WWhiteFIRE/FEU50FW962WWhiteFIRE/FEU20, 35, 50, 85, 105, 130StrobeFW981RRedFIRE/FEU50FW982RRedFIRE/FEU20, 35, 50, 85, 105, 130FW981WWhiteFIRE/FEU50FW982WWhiteFIRE/FEU20, 35, 50, 85, 105, 130HornFW971RRedFIRE/FEUNAFW971WWhiteFIRE/FEUNA


Physical/Electrical Specifications

Standard Operating Temperature32°F to 120°F (0°C to 49°C)Humidity Range10 to 93% non-condensingStrobe Flash Rate1 flash per secondNominal VoltageRegulated 24 DC/FWROperating Voltage Range216 to 33 V (24 V nominal)Input Terminal Wire Gauge12 to 18 AWGWall-Mount or ceiling-Mount Dimensions (including lens)Diameter :140mm (5.5 inch)Hight: 72mm(2.84 inch)RMS Operating Current(mA)DT961RDC117DT961WDTR124DT981RDC75DT981WDTR75Sound Level (dBA)Voltage16V24V33VReverberant808285Anechoic858991Directional CharacteristicsHorizontalAngleOSPL (dBA)Axis0° (ref)0 (ref) ± 44°-3 ± 54°-6 ± 90°-10.5VerticalAngleOSPL (dBA)Axis0° (ref)0 (ref) ± 52°-3 ± 55°-6 ± 90°-12Effective Light (cd)50 at default settingOperating Temperature0° C to 49° C (32° F to 120° F)Operating Humidity0 to 93% RHHorn PatternTemporal 3Strobe Pattern1 flash per secondWire Size12 to 18 AWGLocationIndoor walls or celingCompatible ModelDT951 Sync Module, DT106 FACP

Operating Voltage16 to 33 VDC/FWRRMS Operating Current @16 Vdc (mA) 130cd105cd85cd50cd35cd20cdDT962R16412685554730DT962WDT982R15611980494328DT982WRMS Operating Current @16Vfwr (mA) 130cd105cd85cd50cd35cd20cdDT962R187158102665838DT962WDT982R15415097615335DT982WSound Level (dBA)Voltage16V dc/fwr24V dc/fwr33V dc/fwrUL Reverberant778185ULC Anechoic858891Directional CharacteristicsHorizontal AxisAngleOSPL (dBA)0° (ref)0 (ref)± 44°-3± 54°-6± 90°-10.5Vertical AxisAngleOSPL (dBA)0° (ref)0 (ref)± 52°-3± 55°-6± 90°-12Effective Light (cd)130, 105, 85, 50, 35, 20Operating Temperature0° C to 49° C (32° F to 120° F)Operating Humidity0 to 93% RHHorn PatternTemporal 3Strobe Pattern1 flash per secondWire Size12 to 18 AWGLocationIndoor wall/ceilingCompatible ModelDT951 Sync Module, DT106 FACP


FIRETECH provides wide-ranging of Addressable/Conventional Fire Alarm Sytstem and products (UL/EN54), Please feel free to contact us for more details if you have any enquiry.