Circuit specificationsDT106 Device loops1 to 4 Class B or A loop, supporting 252 devices per loopCommunication line voltageSLC output range: 20.4 to 28Vdc. (24 V nominal)Circuit current220 mA
SpecificationsNACCircuit Type2 Class B or AVoltage24 VDC nominalCurrent4.0 A total, 2.0 A max. per circuitImpedance1.8 V maximum line voltage dropEOLR10 K Ω, 1/4 WSynchronizationSupported system-wide
AlarmTroubleSupervisoryTypeForm CVoltage30VDC, 2A
Relay circuits can only be connected to power-limited sources.
Annunciator loop
The control panel provides a connection for up to four supervised remote annunciators.
Annunciator Wire Selection Guide
[AWG]Wire Resistance (Ohms/km)ftm125.31154434708136.69122573737148.45970429591510.6773623581613.5607418521716.3503115341821.438321168
Specifications
DT106Device loops1to 4 loops, Class A or B, each loop supporting up to 252 device addresses.Notification appliance circuits1 to 4 Class B or A
8.0 A DC total
2.0 A DC each max. per circuitPrimary power110 - 120 VAC, 60 Hz, 3.86 A max. 220 - 240 VAC, 50 Hz, 1.96 A max.base panel current standby333 mAbase panel current alarm354 mAInput zones64 max.Remote annunciatorData line length: 15,443 ft. (4,708 m) when using 12 AWG wiringAuxiliary power output circuitAux power: 24 VDC nominal at 500 mA (standby), 1.2A (alarm) Note: For a list of compatible devices, see the DT106 manualLoop circuitMaximum loop resistance: 20 Ω Maximum loop capacitance: 0.1 µF
SLC output range: 20.4 to 26.4Vdc. (24 V nominal)
Operating current (fully loaded loop) Stand by: 100 mA; Alarm: 220 mA Class A and B wiring
Max. resistance between isolators: Limited only by overall wire run lengthsBatteriesType: Sealed lead acid Voltage: 24 VDC (2 x 12 V batteries connected in series) Charging current: 1.756 A; max. Amp hour capacity: 40 Ah; Standby operation: 24 hour Placement: Up to two 40 Ah batteries will fit in the DT106 control panel cabinet.Relays OutputOne programmable relay
4 non-programmable status relays Status: Alarm, Supervisory, Trouble, Monitor Form C Contact
Contact Rating: 2A 30VDC
Power Factor Ration:0.35Notification Appliance CircuitsTotal of 4 circuits supported, total power available 8A
2 Class A or 2 Class B circuits on each NOU
Maximum Current: 2A per NAC circuit
Alarm Voltage: 24V nominal
Bell code: Temporal 3
Panel supports one regulated 24 VDC NAC, or four special application 24 VDC NAC. Refer to Table 20 for specific appliances/devices.
Max line loss: 1.8 V.Ground fault impedance0 to 6.6 kΩAlarm contactForm C 30 VDC at 2 A (pf=0.35)Trouble contactForm C 30 VDC at 2 A (pf=0.35)Supervisory contactForm C 30 VDC at 2 A (pf=0.35)EnvironmentalTemperature: 0 to 49˚C (32 to 120˚F) Relative humidity: 0 to 93% noncondensingTerminal ratingAll terminals rated for 12 to 18 AWG (0.75 to 2.5 mm²)
FIRETECH provides wide-ranging of Addressable/Conventional Fire Alarm Sytstem and products (UL/EN54), Please feel free to contact us for more details if you have any enquiry.