LSS series vertical water tube automatic oil/gas fired hot water boiler
1. This series of boiler is vertical design,the burner located at its top, which have below advantages:
save more space,east installation and maintenance,less investment of boiler room fundation building.
2.New type W stype smoke process, speical tube structure, thermal efficiency can upto 86%.
3.Less water volume, quickly heating, end user can make it working quickly.
4.Full automation cotrol,complete safety protection device.
5. This boiler have inner and outer two stage steam-water separator ,it can enhance the steam quality.
NameLSS0.21-0.4/95/70-Y(Q)LSS0.35-0.4/95/70-Y(Q)LSS0.52-0.4/95/70-Y(Q)LSS0.7-0.4/95/70-Y(Q)Rated thermal power(Mw)0.210.350.520.7Rated working pressure(Mpa)0.40.40.40.4Rated outlet water temperature(ºC)95959595Rated back water temperature(ºC)70707070Suitable fuel light Diesel/natrual gas/LPG Heating surface(m²)4.6988.14512.7515.07Light Diesel consumption(kg/h)19.933.2449.566.6Natural gas consumption(Nm³/h)22.938.357.176.7LPG consumption(Kg/H)18.831.446.762.8Designed Efficiency(%)88.2589.2688.0388.03Boiler Size (mm)1213X18351440x19121548X25281648x2728Boiler body weight(kg)1380153327002990