China Voltage Transformer Current Transformer CT

Get Latest Price
Min. Order / Reference FOB Price
1 Piece Contact Supplier
Local Area: Wenzhou, Zhejiang, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Application: Instrument, Measurement and Protection
Type: Voltage Transformer
Phase: Single
JDZX10-3,6,10 Type Voltage TransformerApplicationsJDZX10-Packing Machinery 3, 6, 10 Voltage Transformer is suitable for power meaInstrument Box surement, current monitoring and relay protection in power system with Rated frequency 50Hz or 60Hz and Rated voltage 3-10kV.
Applicable Standard: IEC60044-1, GB 1207Type Designation
Operation ConditionsWelding Equipment Installation area: Indoor.
Ambient temperature: Max. temperature 40ºC;Min. tHeating, Refrigeration & Temperature Control emperature -5ºC;Daily averaDrilling Rig ge temperature can't exceed 30ºC.
Air conditions: No heavy pollution in air.Technical ParameterModelRated voltage radio
(kV)Combined accuracy or Combined accuracy classesRated output
(VA)ltimate output
(VA)Rated insulation level
(kV)JDZX10-33/√3/0.1√3/0.1/30.2/6P(3P)15/502003.6/25/400.5/6P(3P)30/50JDZX10-66√3/0.1√3/0.1/30.2/6P(3P)15/502007.2/32//600.5/6P(3P)30/50JDZX10-1010√3/0.1√3/0.1/30.2/6P(3P)15/5020012/42/750.5/6P(3P)30/50Structure and FeatureThe Voltage Transformer is of Post type. Its hermetically sealed by epoxy resin, with design advantages of anti-pollution, anti-damp, easy to be installed is also suitable for tropic area and free from special maintenace except periodically surface clean. Secondary outlet terminal is equipped with connection terminal box. Upside and profile of the box have a hole respectively. The two holes together with outlet terminal are for leading out. Six holes at the bottom of the PT are suitable for mounting.
Outline and Mounting Dimensions
Information Required for Order PlacingModel.
Rated voltage radio kV.
Combined accuracy classes and Rated output VA.
Altitude m.