Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Current Transformer, Split Core Current Transformer, Split Current Transformer manufacturer / supplier in China, offering Waterproof Outdoor Split Core CT Current Transformer for Power Meter, 500/5A Split Core CT Current Transformer, 2500 AMP Accu CT Split Core Current Transformer 333mv Sensor and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Electronic Instrument Calibrator China Voltage Transformer Tester Portable Voltage Transformer Tester Transformer Tester

China Voltage Transformer Tester Portable Voltage Transformer Tester Transformer Tester

Get Latest Price
Min. Order / Reference FOB Price
1 Set Contact Supplier
Local Area: Chaoyang, Liaoning, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Application: Mechanical Instrument, Electromagnetic Instrument
Power: Electricity
Certification: FDA, CE, IAF, CCC
CT/PT TESTERGF106 Portable PT Voltage transformer tester is mainly used for field testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.Features
Steady and transient state characteristic tests of various types of CT/PT
The use of advanced power technology, the test knee point reaches up to 40kV
No external other auxiliary equipment, stand-alone to complete all test items
CT test, easy to test, all the tests are using the same wire connection except the load test
It carries with thermal printer, so it can print test results on site
Parameters such as knee point current and voltage
Parameters such as 10% error curve, 5% error curve
The device can store 3000 groups of test data which would not be lost if the device is power off.
The data can be displayed and analyzed after the test, or transferred to PC through USB disk and produce a Word file report
Portability: weight < 12kgFUNCTIONI. Current Transformer (CT)II. Voltage Transformer (PT)1. Magnetization curve1. Excitation characteristic test2. Transformation ratio test2. TransformatioPackaging Materials n ratio test3. Polarity3.Polarity4. 5% and 10% error curve4. Ratio error, phases5. Current Injecting5.Degauss6. Degauss6. Calculation of knee point value7. Ratio error, phases7. Actual secondary load (burden), test (burden)8. Automatic calculation of excitation knee point value8. Resistance test9. Actual secondary load test (burden) (load test)10. Resistance test11. Secondary winding time constant (Ts)12. Remanence coefficient (Kr)13. Transient dimensioning factor (Ktd)14. Peak instantaneous error (Er)15. Magnetizing inductance (LU)
ParametersElectrical parametersAccuracy0.05%, 0.1%Power supplyAC 220V±10% or AC 110V±10%, 50/60HzExcitation output voltage0-220VrmsExcitation output current0-5Arms (20A peak-valEnvironment Protection Device ue)Automatic frequency variation range0.1-60HzEquivalent excitation voltage≤5000VAccuracy≤0.5% (0.2%RD+0.3%RG)Secondary winding DC resistance measurementRange0.1-300ΩAccuracy≤0.5% (0.2%RD+0.3%RG)Secondary actual load measurementRange5VA-1000VAAccuracy≤0.5% (0.2%RD+0.3%RG)±0.1VACT/PT phase error measurementAccuracy±4minResolution0.01minCT ratio error measurementRange1-30000Accuracy≤0.5%PT ratio error measurementRange1-10000Accuracy≤0.5%StandardsReference standardsGB1207-2006, GB1208-2006, GB16847-1997
IEC60044-1, IEC60044-6, IEC61869-2-2012Safety standardsGB 4793.1-2007EMCEMC standard 89/336/EECFCC Subpart B of Part 15 Class AIEC 1000-4-2/3/4/6Mechanical parametersOverall dimension (L x W x H) Riveter (mm)410 x 250 x 300Weight (kg)≤10Environmental conditionsRelative humidity90RH%Operating temperature-10°C to +40°CAltitude≤2000m
Main functionsThe test items mainly includeSteadyTransientexcitation characteristicsecondary winding time constant (Ts)transformation ratioremanence coefficient (Kr)polaritytransient dimensioning factor (Ktd)ratioValve errorpeak instantaneous error (Er)phasesmagnetiziFeeder ng inductance (LU)5% and 10% error curvesother parametersresistancesecondary loadhttp:https://www.gfuve.com/transformer-test/ct-pt-TESTER.html