Business Type:
Manufacturer/Factory
Business Range:
Electromagnetic Water Meter, Electromagnetic Flow Meter
Establishment:
2011
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Conductivity Probe, Electrical Conductivity Sensor, Water Conductivity Sensor manufacturer / supplier in China, offering High Quality Online Industrial Digital Conductivity Sensor, Double-Head Integral Type Electromagnetic Flow Meter, Stainless Steel Magnetic Beer/Water/Milk Sanitary Electromagnetic Flow Meter for Brewery and so on.

1
    YRS
General Supplier
Supplier Homepage Instruments & Meters Analysis Instrument Liquid Analyzer China Wall-Mounted Conventional Five-Parameter Online Water Quality Monitor

China Wall-Mounted Conventional Five-Parameter Online Water Quality Monitor

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $6000.00/ Piece
Local Area: Jian, Jiangxi, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Display: Touch Screen
Appliance: Food Analysis, Medical Research, Biochemistry, Water Quality Testing and Analysis
Portable: Non Portable

Wall-mounted Conventional Five-parameter online Water Quality Monitor
Product description
DG-DCSG-2099 online multi-parameter water quality monitor can simultaneously measure: conductivity, TDS, resistivity, temperature, pH, ORP, dissolved oxygen, oxygen saturation, chlorine, total of nine parameters. The channels are independent, non-switch conversion, without disturbing each other.

online Multi-parameters water quality Analyzer integration platform, it can directly integrate a variety of water quality online analysis parameters in a whole machine, in the touch screen panel display focused on and management; the system set on-line water quality analysis, remote data transmission, database and analysis Software, system calibration functions in one, the modernization of water quality data collection and analysis provides a great convenience.

Flexible configuration of the combination, the cabinet inside the sample and analysis of the part can be flexible matching (Note: the specific parameters to the actual ordering parameters prevail): pH, conductivity, temperature, and other conventional parameters, the actual needs of customers should be combined or extended ; Water part of the use of the company's latest application research results - tandem flow analysis device, the water required little, real-time strong, a small water flow through a variety of sensors in accordance with the different technical characteristics and response order , Water samples through the flow of all parameters when the real-time capture, but also to achieve the external large-scale continuous expansion of the unit.


Product features
1. Personalized parameter customization combination, flexible combination, matching and customization of corresponding monitoring parameters according to customer monitoring requirements;
2. Intelligent on-line monitoring application is realized through flexible configuration of intelligent instrument platform software and combined parameter analysis module;
3. Drainage integrated system integration, tandem type circulation device, using a small number of water samples to complete a variety of real-time data analysis;
4. With automatic online sensor and pipeline maintenance, it rarely needs manual maintenance, creates a good operating environment for parameter measurement, integrates and simplifies complex on-site problems, and eliminates uncertainties in the application process;
5. Built-in decompression device and constant flow rate patent technology, which are not affected by pipeline pressure changes, ensuring constant flow rate and stable analysis data;
6. A variety of optional remote data links, remote databases that can be leased and built, allowing customers to easily master data in the far places.(optional)
Product parameters

System modelDG-DCSG-2099Measurement configurationPH / conductivity / residual chlorine / turbidity / temperature (Note: the specific parameters are subject to the actual order parameters)Measuring rangePH0-14.00PH Conductivity0-2000uS/cm Residual chlorine0-20.00mg/L Turbidity0-20NTU temperature0-150ºC(Thermal element:PT1000)Resolution and accuracyPHResolution:0.01pHaccuracy:±1%FS ConductivityResolution:1μS/cm accuracy:±2%FS Residual chlorineResolution:0.01mg/L accuracy:±1%FS TurbidityResolution:0.01NTU accuracy:±1%FS temperatureResolution:0.1ºCaccuracy:±0.5ºCCommunication InterfaceRS485working power supplyAC 220V±10%working surroundingstemperature:(0-50)ºC;Storage environmentRelative humidity:≤85% RH(No condensation)Cabinet size1100mmx420mmx400mm(Height x width x depth)

3Application scene
1. Environmental sampling inspection in large watershed.
2. Used by laboratory researchers.
3. Fishery aquaculture environmental monitoring.
4. Monitoring of sewage outlets in sewage plants.
5. Rivers, lakes, creeks, etc.Measurement principle
1. PH: The potential difference measured in the solution according to the working battery composed of the measuring electrode and the reference electrode, and using the linear relationship between the pH value of the solution to be tested and the working battery potential, converted to the corresponding pH value by the transmitter.
2. Residual chlorine: A microbattery measurement system consisting of two platinum electrodes and one reference electrode. During measurement, a stable potential is maintained at the measuring end of the electrode, and different measured components produce different,good linear current intensities at this potential.
3. Conductivity: Conductivity (G) is the reciprocal of resistance (R). Place two parallel plates in the solution to be tested, apply a certain potential to both ends of the plate(usually a sinusoidal voltage), and measure the current flowing between the plates. The conductivity is calculated according to Ohm's law.
4. Turbidity:Using 90° scattering method. A near-infrared light beam of 880 nm emitted from the LED light source on the sensor is irradiated into the water sample to be detected, and suspended particles in the water sample are scattered to form scattered light.

5. OUrMeasurement pr