Business Type:
Manufacturer/Factory
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
OEM/ODM Service
Sample Available

Electric Bed, Rehabilitation Therapy, Rehabilitation Products manufacturer / supplier in China, offering Rehabilitation Equipment Electric Tilting Bed for Gradual Adoptive Standing Training, China OEM Serial Port Ttl NIBP Board for Hemodialysis Monitoring, OEM Neonates Children Use Non-Invasive Blood Pressure Module and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment China Wireless Mainstream Capnograph Etco2 with Rechargeable Battery

China Wireless Mainstream Capnograph Etco2 with Rechargeable Battery

Get Latest Price
Min. Order / Reference FOB Price
1 Pieces US $550.00/ Pieces
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Capnograph
Certification: MSDS, ISO13485

Product nameWireless CapnographMOQ1


ETCO2(End-tidal CO2) monitoring is essential during many types of medical procedures ranging from routine respiratory observation to open heart surgery, as well as any time general anesthesia must be administered.

Capno EMER has becoming the smallest wireless End-tidal CO2 Monitor in the world,

Achieving the measuring of ETC02 and Respiratory Rate in all Respiratory Conditions.

Its small size, light in weight and low energy consumption(2 AAA chargeable battery

can last for 4 hours), makes it flexibility and convenience obviously. Suitable for CPR

and emergency transportation.
1. Montioring the patient's respiratory status during CPR
2. Monitoring the patient's respiration during transportation
3. Verificating of ET tube placement



1. Transducer Type:
Capno EMER Wireless Mainstream Capnograph
2. Co2 Accuracy:
Range 3 - 150 BPM
Accuracy ± 1 breath
3. Alarm:
Check adatper, No breath, Battery too low, ETCO2 too low,ETCO2 too high,
RR too low, RR too high
4. Calibration:
No routine user calibration required, An airway adapter zero is required when Changing to a different airway adapter
5. Power Requirements:
Battery:2 AAA chargeable Battery (2x1.5VDC)
Suggestion:Please use the original battery
Dimension:
Size: 56(L)X 24(W)X 40(H) mm
Weight:
27.5g(not include battery); 50g(include battery)
Regulatory:
Designed to comply YY0601 and ISO21647
(user optional)
1: Neonatal airway adapter
2: Adult airway adapter
3: Manual resuscitator


DHL, Fedex, TNT, UPS, EMS......
Which ever is convenient for you.
TT, Paypal & Western union are all fine.