Cable, Power Cable, Xlpe Cable manufacturer / supplier in China, offering Electric/3 Core/XLPE Insulate Power Cable, Low Voltage 25 Sq mm Copper Core PVC Insulated Wire, Solid Copper Core 2.5mm Electrical Cable Price and so on.
Min. Order / Reference FOB Price | |
---|---|
1000 Meters | US $0.49/ Meters |
Local Area: | Xinxiang, Henan, China |
---|---|
R&D Capacity: | OEM, ODM, Other |
Payment Terms: | LC, T/T, PayPal, WesternUnion |
Brand: | Jinshui |
---|---|
Type: | Insulated |
Conductor Type: | Stranded |
Application: | Overhead |
0.6/1KV Aerial Bundled Cable ABC Cable
Applications
Used to supply 3 phase power, usually from a pole- mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross linked polyethylene (XLPE) insulated conductors.
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or XLP cross linked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
Standards
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum conductors, Concentric-Lay-Stranded. B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded, 6201-T81 Aluminum Alloy Conductors.
B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Quadruplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
Note :
Designated sizes are : ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTMB-399 for
6201.Conductor temperature of 90°C for XLR 75°C for Poly; ambient temperatures of 40°C; emissivity 0.9;
2ft./sec/wind in sun. To determine current ampacity by conductor size, please consult The National Electric
Code, latest edition.
Code Name
Phase Conductor
Bare Neutral Messenger
Weight Per 1000ft (lbs)
Ampacity(amps)
Size AWG
Stranding
Insulation Thickness(mls)
Size AWG
Stranding
Breaking Strength(lbs)
XLPE
Poly
XLPE
Poly
6201 ALLOY NEUTRAL-MESSENGER
Minex
6
Solid
45
6
7
1,110
106.6
102.9
85
70
Hippa
6
7
45
6
7
1,110
113.2
105.7
85
70
Prawn
4
Solid
45
4
7
1,760
158.4
154.1
115
90
Barnacles
4
7
45
4
7
1,760
168.3
158.2
115
90
Shrimp
2
7
45
2
7
2,800
253.7
239.7
150
120
Gammarus
1/0
7
60
1/0
7
4,460
411.7
386.0
205
160
Leda
1/0
19
60
1/0
7
4,460
402.7
386.0
205
160
Dungenese
2/0
7
60
2/0
7
5,390
506.8
476.3
235
185
Cyclops
2/0
19
60
2/0
7
5,390
495.3
476.3
235
185
Dlustra
3/0
19
60
3/0
7
6,790
611.4
589.1
275
215
Lepas
4/0
19
60
4/0
7
8,560
757.1
730.5
315
245