Business Type:
Trading Company
Business Range:
X ray machine, Ultrasound, Vet items, Dental items
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, WesternUnion
Main Markets:
Southeast Asia, Middle East, Africa, Others
OEM/ODM Service
Sample Available

Hospital Equipment, Medical Equipment, Medical Supply manufacturer / supplier in China, offering Ysenmed One-Station Shopping Medical Hospital Equipment, Hospital Ysav200A Built-in Oxygen Air Blender Baby Neonatal Ventilator, Medical Ysvv500 Blood Locator Detector Finder Portable Vein Viewer and so on.

1
    YRS
General Supplier

China Yste180c Fully Automated Chemistry Analyzer

Get Latest Price
Min. Order / Reference FOB Price
1 Set Contact Supplier
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, WesternUnion
Classification: Biochemical Apparatus
Type: Biochemistry Analyzer
Temperature: 10-30 Degree
Medical Full auto chemistry analyzer Yste180c
Throughput constant 180 T/h or 300T/h, best for middle or small size hospital
Closed integrated photovoltaic systems, no mechanical parts, maintenance free
Minimum reaction volume is 150UL, cost saving
Discrete, random access, automatic
Random choice of method, the real discrete automatic chemistry analyzer
This automatic chemistry analyzers have gained a lot of national patents during the researching.
Analyze Unit
L Throughput: Constant 180 T/h, 81 reaction cuvette positions, multi-channel testing together.
L Minimum reaction volume is 150μ L, cost saving.
L Determined by the sample sequence, inserted at any time emergency.
L Heating method: Direct thermal solid thermostat closed.
Optical Unit
L Closed integrated photovoltaic systems, no mechanical parts, maintenance free.
L Light Source: Halogen-tungsten lamp;
L Lifetime≥ 2000 h.
L 8 Wavelength, support single or dual wavelength.
Reagent Unit
L 60 reagent positions.
L Automatically detect the amount of reagent remaining, displayed in real time the remaining amount of reagent.
L 15ml, 20ml, 30ml, 50ml or 70ml reagent bottle. Dead volume <1.0 ml.
L Support for single and double reagent, reagent completely open.
Internal barcode reader (option).
Sample Unit
L 60 sample positions.
L Testing according setting, random access.
L Real time display of testing status.
L Internal barcode reader (option).
Reagent/Sample handing Unit
L Intelligent liquid detection & collision protection (Red light: Collision; Blue light: Detection of the liquid).
L Reagent volume: 2 ~ 500μ L, step by 1μ L.
L Probe cleaning: Automatically washing for both inside and outside, carry over0.1%.
L Automatically dilute and retest.
Calibration and quality control Unit
L Linear curve type: Single-point linear, two-point linear and multi-point linear.
L Nonlinear curve type: Logit-4p, Logit-5p, polynomial, factor.
L Automatically use best calibration curve and standard.
L Quality control chart: L-J, Westgard TwinPlot, Cumulative.
Operation Unit
L Operation system: Windows XP/Office 2000, interface is intuitive and operate it easily, arbitrary operating authority; No restrictions on the amount of time and storage, permanent preservation of various types of data, automatic storage and backup.
L Can print the contents of any custom; Offers a variety of print formats.
L Help and operation guide on line in English.
L No restrictions on setting test parameters.
L Unique password for user management, rational allocation of user rights.
L Real time display of testing status, the remaining amount of reagent, testing status, reaction curve and the test progress.
L Real time display of reaction plate temperature.
RS-232 standard interface, support for the hospital network, print reports remotely.
Others
L Temperature: 10-30 degree
L Humidity: Less than 70%.
L Try to avoid strong light.
L Floor level up: Less than 1/200.
L Barometric: 86.0kPa-106.0kPa.
L Power Supply: AC 220V± 22V 50Hz± 1 Hz.
L Water consumption: Less than 6L/h.
L Frequency: 550 VA.
L Dimension: 782mmx 581mmx 545mm
L Weight: 60kg
Test projects
L ALT, AST, TP, ALB, TBIL, DBIL, ALP, r-GT, CHE, TBA, 5-NT
L UREA, CR, UA, TCO2
L CHOL, TG, HDL, LDL, ApoA, ApoB, LPa
L AMY, LIP
L GLU, GSP
L CK, CK-MB, a-HBDH, LDH, MB
L CRP, RF, ASO
Specifications

Ysenmed ® Yste180c
Automatic Chemistry AnalyzerSpecificationsAnalyze UnitThroughputConstant 180T/h (non-ISE)TheoryAbsorption spectrometry, transmission turbidimetryMethodologyEnd-point Fixed-timeKineticIon selective electrodeTest according set up, random accessReaction plateContain 81 reaction cuvettesMaximum reaction time15 minutesMinimum reaction volume150 ulMaterial of cuvettesSpecial UV-transparent optical glassCuvettes useAutomatically cuvettes washingOptical UnitLight SourceHalogen-tungsten lampPhotometerReversed opticsWavelength340nm-900nm wavelength optionAbsorption0-4 AbsReagent UnitReagent plate60 reagent positions ,support for single and double reagent, reagent completely openReagent storage temperature2~10 degreeReagent bottle15ml, 20ml, 30ml, 50ml or 70ml ,dead volume is less than 1.0 mlReagent volume20-500 ul, step by 1.0 ulReagent/Sample ProbeAutomatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.Sample UnitSample plate60 sample positionsSample typeHuman (animal) serum plasmaurine etc.Samples cupSupport one-off micro cupsSample volume2-100 ul, step by 0.1 ulSample/reagent probeAutomatically checked ;Patent technology liquid level detection;Collision protection probe cleaning:Automatic washing for both inside and outside.Temperature control UnitHeating methodDirect thermal solid thermostat closedTemperature equilibrium time<3 minutesReaction temperature37 ±0.1 degreeTemperature fluctuation±0.1 degree Operation UnitSoftwareWindowsXP 2000DatabaseSQL ServerData StorageAutomatic store & copy; No time and volume limit; Lifetime preservationPrint formatCan be set up, offer several standard formatCalibration modeLinear curve type: Single-point linear, two-point linear and multi-point linear none linear; Curve type: Logistic-Log 4P,Logistic-Log5p,Spline,index automatically use best calibration curve and standardQuality control methods :Real time, within day & between dayQuality control diagramL-J cumulativetwin plotStatus displayReal time monitoring of reagent residual volume .Running status of reagent tray, samples trayAdjustmentDynamic and real time display of running status; Intelligent carry over settings to adjust test sequence; original reaction data record; Detail profile of alert messagesSettingOperation permission setting, Item setting, cross pollution setting, cuvette blank settingOthersWater consumption : < 6L/hPower Supply :AC 220V±22V 50Hz±1HzFrequency :Maximum 600VADimension :782mmx581mmx545mmNet Weight : 60kgAccessory :Software


We listed some hospital basic items for your reference as below:

One-stop shopping
Hospital medical equipmentX ray roomX ray machineProcessorX ray filmCassetteIntensifying screenLead clothings(lead glove, lead glasses,
Lead cap, lead apron, lead collar)UltrasoundB/w 2D ultrasound2/3/4D color ultrasoundLaboratory roomChemistry analyzerHematology analyzerMicroplate elisa readerMicroplate washerCentrifugePipetteWater bathUrine analyzerOperation roomAnesthesia machineVentilatorOperating lampOperation tablePendantMedical drill and sawECGPatient monitorDefibrillatorInfusion pumpElectrocoagulationOxygen generatorElectric suction deviceAutoclave sterilizer