Business Type:
Trading Company
Business Range:
X ray machine, Ultrasound, Vet items, Dental items
Establishment:
2012
R&D Capacity:
ODM, OEM, Other
Terms of Payment:
LC, T/T, WesternUnion
Main Markets:
Southeast Asia, Middle East, Africa, Others
OEM/ODM Service
Sample Available

Hospital Equipment, Medical Equipment, Medical Supply manufacturer / supplier in China, offering Ysenmed One-Station Shopping Medical Hospital Equipment, Hospital Ysav200A Built-in Oxygen Air Blender Baby Neonatal Ventilator, Medical Ysvv500 Blood Locator Detector Finder Portable Vein Viewer and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment China Ysx300 300mA Hospital High Performance Medical X-ray Machine

China Ysx300 300mA Hospital High Performance Medical X-ray Machine

Get Latest Price
Min. Order / Reference FOB Price
1 Set Contact Supplier
Local Area: Guangzhou, Guangdong, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, WesternUnion
Classification: Imaging Diagnostic Equipment
Type: X Ray Equipment
Certification: ISO13485
300mA Hospital High Performance Medical X-ray Machine YSX300

Unit Configuration :

Control, HT generator unit,Ht cable,X-ray tube unit,Radiographic table-X-ray source column ,Collimator

Main Characteristics of X Ray Machine:

1 Single-table/single-tube

2 Rotary anode X-ray tube unit and tangential annular tube head

3 Single-phase full wave rectification high-voltage generator

4 Power voltage(v) radiograph kilovolt (KV).step-less control electric mechanism

5 Filament stabilizer for X-ray tube unit and space charge compel mentor

6 Radiograph volume KV mA and S. grading and interlock protection

7 Adopt digital circuit timer. Grading according to R10 priority coefficient,(for more accurately controlling time)

8 HT primary, the zero controlled circuit of silicon-controlled rectifier of heavy power.

9 Radiographic table can move in length an breadth.

10The radiographic table. Column and vibrating grid are in a whole without ceiling and floor rails bottom.

Main Technical Indexes

ITEM

CONTENTS

INDEX

Demand of

power supply

Capacity

Two-phase 30KVA

Voltage Frequency

380V/220V±10%50HZ ±0.5Hz

Intemal resistance

0.75Ω(380V)0.25Ω(220V)

power supply

Adjustable range

380±10% at220V being adjustable continuously

Radiograph

Voltage

50-100KV being adjustable continuously

current

Small focus:50mA100mA,Big focus:50Ma 100mA

200mA 300mA

time

0.04~6.35s 23grades together grading a according to

R10 coefficient

High-voltage generator

Capacity

20KVA(instantaneous)

Max DC output voltage

100KV

Max DC output current

200mA

X-Ray tube

Model

XD51.20-40/100

Focus

Small focus 1*1mm big focus2*2mm

Radiographic table

Length*width*height of

bed surface

2000mm*665mm700mm

Moving range of bed surface

640mm in Length,200mmin breadth

Ray-filter of table

Travel in length ≥500mm

Grid density N=28

Convergence distance f=100cm

Grid ratio r=8

Column of X-ray tube unit

Moving Longitudinally along

Radiographic table

1000mm or 1800mm

Distance to friend as moving up

and down (along column)

650~1800mm

Rotary around the center

of cross arm

±180°

Rotary around the shaft line

of X-ray annular tubes

-10°~60°~ +120°

Max size of cassette

356mmx432mm(14x17)