Zysw1000va Single Phase online Home UPS Inverter with Charger
*I/P: 220VAC or 110VAC,O/P:220VAC or 110VAC
*12VDC For 500VA/800KVA/1KVA/1.2KVA ,0.8PFor 24VDC 1.2KVA,0.8PF
*Smart Charging 15-20Amp,Off Charging function
*Adjustable charge current or adjusted input Range
*AVR function is option (ZYSW*A )
*Silence setup and Cooling Fan with speed control
*Auto-restart when AC resume
*USB Communication is option
Key words:
Low frequency pure sine wave inverter with charger
Auto transfer time 10 Ms.
Smart Charging ,Off Charging function
Protection for overload,short-circuit,Battery Low protection.
self-testing while starting
Auto-restart when AC resume
Silence setup and Cooling Fan with speed control
OPTIonAL :
LCD display Option
AVR function is option (ZYSW*A )
175-270V or 90-290V input selectable for ZYSW-"A"
50% or 100% charge current selector for ZYSW/ZYSW*A-"B"
USB Communication is option---"C"
The above "A" or "B", only can select one of them .
When select the "C" then cannot select the "A"and "B"
Techinical data
ModelZYSW600(A) ZYSW800(A) ZYSW1000(A)ZYSW1200(A)Maximum Output Power(W)600VA
800VA1000VA 1200VA500W640W800W1000WInputVoltage for ZYSWInverter mode: 80-290Vac±5Vac,UPS mode:175-270Vac±5VacVoltage for ZYSW-A145-270Vac±5Vac. The Mode with AVR FunctionFrequency45Hz-65HzOutputVoltage for ZYSWInverter mode: 80-290Vac±5Vac(AC mode)220Vac±5% (DC mode)Voltage for ZYSW-A UPS mode:175-270Vac±5Vac(AC mode)220Vac±5% (DC mode)Frequency50Hz ±5Hz (DC mode)Output Waveform sine waveGeneral Protection Output Short; Over Voltage; Low-Voltage; Power Utility Short; Low Battery VoltageDC voltage 12VDC 12VDC 12VDC 12VDC/24VDCCharge Current 15Amp 15Amp 20Amp20AmpBatteryBattery TypeValve controlled maintenance free sealed lead-acid battery600K(A)-1.2K(A)12VDC External 12VDC External 12VDC External 12VDC/24VDC External Transfer Time(ms) Max 10MSMax 10MS < 150% overload:No beed, > 150% overload :1beep per secondAlarmbattery low,LCD type beeping every 0.5second,LED type fault LED flashes,
when overload:UPS beep every 0.5secondCommunication InterfaceUSB communication optionSurge protection YesLED DisplayLine ,Charge,backup,Fault. UPS/Inverter Mode select or Charge currentLCD Display Auto turn-on,AVR mode,HZ, VAC,Bat % , Load %Product size WxDxH (mm) 290*255*120290*255*120290*255*120290*255*120CTN sizeWxDxH (mm) 355*325*230 355*325*230 355*325*230 355*325*230 CTN Weight (Gross/Net) (KG)8 / 7.3 11.01 / 10.311.65 / 10.9 13.66 / 13REMARKZYSW*K --- Without AVR Function, ZYSW*K-A----With 3step of AVR Function