KonNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:*Panasoniccompressor&R410arefrigerant,ORCopelandcompressorandR417arefrigerant;*Stainlesssteel304forallfasteners,forsidecoversofevaporator;*Preservativeoilforcoppertubesandallimportantpartofcabinet;*ChineseNo.1brand"ND"shell&tubeheatexchanger;*Japan"Saginomiya"or"Sanhua"electronicexpansionvalve;*"Sanhua"4-wayvalve;*"Schneider"ACcontactor&Relay*LCDcontroller;*Deliverytime:20~25days;*Paymentterm:T/T30%inadvanceandT/T70%beforedelivery;*Warrantytime:24monthsafterdelivery.
WE SUPPLY OEM SERVICE!KonNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
KonNEN AIR SOURCE HEAT PUMP, AIR TO WATER HEAT PUMP, COMMERCIAL USE:*Panasoniccompressor&R410arefrigerant,ORCopelandcompressorandR417arefrigerant;*Stainlesssteel304forallfasteners,forsidecoversofevaporator;*Preservativeoilforcoppertubesandallimportantpartofcabinet;*ChineseNo.1brand"ND"shell&tubeheatexchanger;*Japan"Saginomiya"or"Sanhua"electronicexpansionvalve;*"Sanhua"4-wayvalve;*"Schneider"ACcontactor&Relay*LCDcontroller;*Deliverytime:20~25days;*Paymentterm:T/T30%inadvanceandT/T70%beforedelivery;*Warrantytime:24monthsafterdelivery.
WE SUPPLY OEM SERVICE!KonNEN NEW FACTORY(HEAT PUMP + WATER TANK + CONTROLLER):
WHY US:
KonNEN NEW PROJECTS:
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
KonNEN HEAT PUMPS LOADING:
PARAMETERS TABLE:
A02Hseries(Airsourceheatpumpwaterheatercirculationtype) HW03Ps-E3HW05Ps-E5HW03P-E3HW05P-E5HW07P-E5HW10P-C24HW14P-C24HW20P-C48HW24P-C48HW30P-C48HW36P-C48HW48P-C96RatedheatingcapacitykW121912192535507585105125165RatedinputpowerkW2.754.392.754.375.758.1011.5717.2019.6024.2028.9038.10RatedinputcurrentA14.0523.105.178.3410.7715.0023.8631.8037.0046.1053.5072.30MaximuminputpowerkW3.385.403.385.387.079.9614.2321.1624.1129.7735.5546.86MaximuminputcurrentA18.2829.196.4310.2113.4418.9327.0540.2045.8156.5667.5489.04Performancecoefficient(COP)/4.364.334.364.354.354.334.324.364.344.344.334.33Ratedhotwateroutputtemp.ºC55Max.hotwateroutputtemp.ºC60RatedhotwaterproducecapacityL/H258408258408537752.510751612.51827.52257.52687.53547.5Powersupply1N220V/50Hz3N380V/50HzCompressorTypeFullyclosedscrolltypeStartModeDirectlystartQuantitySet111112242334WatersideheatexchangerTypeShell&coil(tube)heatexchangerWaterflowm3/h2.13.32.13.34.36.08.612.914.618.121.528.4WaterPressureDropkPa≤50≤55≤50≤55≤55<60<60<65<65<65<65<65PipesizeDNDN20DN25DN20DN25DN25DN32DN32DN50DN50DN50DN65DN80Protections1.Highpressureandlowpressureprotection,
2.Anti-freezingprotection,
3.Hightemperatureprotection,
4.Toobigofthewatertemperaturedifferenceforoutletandinletprotection,
5.Overloadprotection,
6.Lackphaseprotection,
7.Reversephaseprotection,etc..RefrigerantThrottleTypeElectronicexpansionvalveQuantitykg1.92.81.92.84.12.8x24.1x23.2x47.6x26.2x37.6x37.6x4NoiseDB(A)≤55≤63≤55≤63≤65≤65≤68≤70≤72≤73≤74≤78Dimensionmm700x680x
875820x695x
1060700x680x
875820x695x
1060820x695x
10601000x1000x18581000x1000x18581000x2050x19001000x2050x19001000x2050x19801000x2050x19802000x2050x1980NetWeightkg1001601001601903104006056508358401230Testingconditions:1.Applicationsideinitialwatertemperature:15ºC,endtemperature55ºC,max.temperature60ºC.2.Ambienttemperaturedrybulb20ºC,wetbulb15ºC.TheaboveparametersarebasedonRefrigearntR410a,forparametersbasedonotherrefrigerantpleasecontactus.Theaboveparametersmayhavesomedifferencesfromthefinalproductbecauseofproductsupdating,soaboveinformationisnottheprovisionofanybusinesscontract.Pleaserefertofinalproductlabelwhenbuy,orrefertousforanyinformation.Ourcompanykeepstherighttointerpret.WHY US:
KonNEN NEW PROJECTS:
WORLD FAMOUS BRANDS WE COOPERATED FOR OUR HEAT PUMPS:
KonNEN HEAT PUMPS LOADING:
PARAMETERS TABLE:
A02Hseries(Airsourceheatpumpwaterheatercirculationtype) HW03Ps-E3HW05Ps-E5HW03P-E3HW05P-E5HW07P-E5HW10P-C24HW14P-C24HW20P-C48HW24P-C48HW30P-C48HW36P-C48HW48P-C96RatedheatingcapacitykW121912192535507585105125165RatedinputpowerkW2.754.392.754.375.758.1011.5717.2019.6024.2028.9038.10RatedinputcurrentA14.0523.105.178.3410.7715.0023.8631.8037.0046.1053.5072.30MaximuminputpowerkW3.385.403.385.387.079.9614.2321.1624.1129.7735.5546.86MaximuminputcurrentA18.2829.196.4310.2113.4418.9327.0540.2045.8156.5667.5489.04Performancecoefficient(COP)/4.364.334.364.354.354.334.324.364.344.344.334.33Ratedhotwateroutputtemp.ºC55Max.hotwateroutputtemp.ºC60RatedhotwaterproducecapacityL/H258408258408537752.510751612.51827.52257.52687.53547.5Powersupply1N220V/50Hz3N380V/50HzCompressorTypeFullyclosedscrolltypeStartModeDirectlystartQuantitySet111112242334WatersideheatexchangerTypeShell&coil(tube)heatexchangerWaterflowm3/h2.13.32.13.34.36.08.612.914.618.121.528.4WaterPressureDropkPa≤50≤55≤50≤55≤55<60<60<65<65<65<65<65PipesizeDNDN20DN25DN20DN25DN25DN32DN32DN50DN50DN50DN65DN80Protections1.Highpressureandlowpressureprotection,
2.Anti-freezingprotection,
3.Hightemperatureprotection,
4.Toobigofthewatertemperaturedifferenceforoutletandinletprotection,
5.Overloadprotection,
6.Lackphaseprotection,
7.Reversephaseprotection,etc..RefrigerantThrottleTypeElectronicexpansionvalveQuantitykg1.92.81.92.84.12.8x24.1x23.2x47.6x26.2x37.6x37.6x4NoiseDB(A)≤55≤63≤55≤63≤65≤65≤68≤70≤72≤73≤74≤78Dimensionmm700x680x
875820x695x
1060700x680x
875820x695x
1060820x695x
10601000x1000x18581000x1000x18581000x2050x19001000x2050x19001000x2050x19801000x2050x19802000x2050x1980NetWeightkg1001601001601903104006056508358401230Testingconditions:1.Applicationsideinitialwatertemperature:15ºC,endtemperature55ºC,max.temperature60ºC.2.Ambienttemperaturedrybulb20ºC,wetbulb15ºC.TheaboveparametersarebasedonRefrigearntR410a,forparametersbasedonotherrefrigerantpleasecontactus.Theaboveparametersmayhavesomedifferencesfromthefinalproductbecauseofproductsupdating,soaboveinformationisnottheprovisionofanybusinesscontract.Pleaserefertofinalproductlabelwhenbuy,orrefertousforanyinformation.Ourcompanykeepstherighttointerpret.