Business Type:
Manufacturer/Factory,Trading Company
Business Range:
Pulse Oximeter, Fetal Doppler, EEG, ECG Machine, Blood Pressure Monitor, Telemedicine ..
Establishment:
1996
R&D Capacity:
OwnBrand, ODM, OEM
Terms of Payment:
LC, T/T
Main Markets:
North America, Europe, Southeast Asia, Middle East
OEM/ODM Service
Sample Available

Portable Pulse Oximeter, Pulse Oximeter, Oximeter manufacturer / supplier in China, offering Portable Pulse Oximeter with (Perfusion Index) Pi Display, China Manufacturer 12.1" Portable Multi-Parameter Patient Monitor, Contec Ha3100 Blood Hematology Analyzer and so on.

1
    YRS
General Supplier
Supplier Homepage Health & Medicine Medical Equipment Medical Diagnosis Equipment Contec Cms8000 Cheap Multi-Parameter Beside Portable Cardiac ECG Patient Monitor FDA

Contec Cms8000 Cheap Multi-Parameter Beside Portable Cardiac ECG Patient Monitor FDA

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $300.00/ Piece
Local Area: Qinhuangdao, Hebei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient/Fetal/Maternal Monitor
Certification: CE, FDA, ISO13485
Multi-parameter Portable Cardiac Patient Monitor FDA
MODEL:CMS8000 Brand:ConTEC USA warehouse:Chicargo
Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECG Heart rate(HR)
ECG waveform
Arrhythmia and ST-segment analysis
2)RESP Respiration rate(RR)
Respiration waveform
3)SpO2 Oxygen saturation(SpO2)
Plethysmogram(PLETH) waveform
Pulse rate(PR)
Bar graph
4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP T1, T2, TD
6)IBP(optional) CH1:SYS,DIA,MAP
CH2:SYS,DIA,MAP
IBP waveform
7)CO2(optional) EtCO2
InsCO2:Inspired Minimum CO2
AwRR:Air Way Respiration
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP
measurement, alarm event marking and drug concentration calculation, etc.Performance
ECGMulti-parameter Portable Cardiac Patient Monitor FDALead selection: I, II, III, aVR, aVL, aVF, VWaveform: 5-lead, dual-channel3-lead, single-channelGain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mVScan speed: 12.5mm/s, 25 mm/s, 50 mm/sHR:Measurement and alarm range: 15~350 bpmAccuracy: ±1 % or ±1 bpm, whichever is greaterAlarm accuracy: ± 2 bpmResolution: 1 bpmST-segment monitoring:Measurement and alarm range: -2.0 mV ~ +2.0 mVAccuracy: -0.8 mV~+0.8 mV ±0.04 mV or ±10%, whichever is greaterOther range: unspecifiedArrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,PVC, TACHY, BRADY, MISSED BEATS, PNP, PNCPacemaker: yesRESPMethod: R-F(RA-LL) ImpedanceRespiration rate:Measurement and alarm range: 0~150 rpmResolution: 1 rpmMeasurement accuracy: ±2 rpmAlarm accuracy: ±3 rpmApnea alarm: 10~40sScan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/sNIBPMethod: OscillometryMode: Manual/AUTO/STATMeasurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutesMeasurement period in STAT mode: 5 minutesMeasurement and alarm range: 10 ~ 270 mmHgResolution: 1 mmHgCuff pressure accuracy: ±3 mmHgMeasurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal standard deviation: 8 mmHgOver-pressure protection:
Adult mode: 297±3 mmHg
Pediatric mode: 240±3 mmHg
Neonatal mode: 147±3 mmHgSpo2Measurement and alarm range: 0 ~ 100%Resolution: 1%Measurement accuracy: 70%~100%: ±2%;0%~69%: unspecifiedPRMeasurement and alarm range: 30 ~ 250 bpmMeasurement accuracy: ±2 bpm or ±2%, whichever is greaterTEMPChannel: dual-channelMeasurement and alarm range: 0 ~ 50ºCResolution: 0.1 ºCAccuracy: ±0.1 ºCEtCO2Method: Sidestream or Mainstream
Measuring Range: 0~150mmHgResolution:0~69 mmHg, 0.1 mmHg
70~150 mmHg, 0.25 mmHgAccuracy:0~40 mm Hg ±2 mm Hg
41~70 mm Hg ±5%
71~100 mm Hg ±8%
101~150 mm Hg ±10%AwRR Range: 2~150 rpmAwRR Accuracy: ±1BPMApnea Alarm: YesIBPChannel: dual-channelLabel: ART, PA, CVP, RAP, LAP, ICP, P1, P2Measuring and Alarm Range: -10~300 mmHgResolution 1 mmHgAccuracy: ±2% or 1mmHg, whichever is greaterPower supply: 100-240V~, 50/60HzSafety classification: Class I, type CF defibrillation-proof applied part