Digital Signal Recorder, Signal Recorder, Instantaneous Signal Recorder manufacturer / supplier in China, offering Instantaneous Signal Recorder, Portable Current Turn Ratio Transformer Testing Equipment for TTR Testing, ISO Transformer Turn Ratio Test Transformer Ratio Meter with CVT Function and so on.

1
    YRS
General Supplier

Current Transformer Testing Equipment

Get Latest Price
Min. Order / Reference FOB Price
1 Piece US $100.00/ Piece
Local Area: Wuhan, Hubei, China
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Weight: <15kg 
Transport Package: Wooden Cases
Specification: 485mm× 356mm× 183mm
Introduction:HYVA-405 is used to measure all kinds of current transformer and voltage transformer. It can calculate the ratio errors and phase angle errors of current transformer and voltage transformer at rated burden and working burden in one time test. The tester can automatically evaluate the test results according to the selected standard to determine whether the transformer is qualified.Applications:Tests for current transformer:1) Excitation curve and parameters test2) Turns ratio test3) Ratio and phase error test4) Polarity mark check5) Winding resistance measurement6) Secondary loop burden measurement7) Error line curve test for protection CT8) Transient CT parameters test9) CT nameplate guess10) Saturation hysteresis loop curve measurement
Tests for voltage transformer:1) Turns ratio test2) Ratio error and phase angle error test3) Polarity test4) Secondary burden test5) Winding resistance testFeatures:1. Make evaluation for test results according to selected standards.
2. Make word report for test result.
3. Make word reports one time for multi-group test records on the PC.
4. Calculate the ratio errors and phase angle errors at rated burden and working burden in one time test.
5. Compare excitation curves with saved excitation curves in the same window.Technical index
1) Test standards: IEC60044-1, IEC60044-6, IEC60044-2, IEC60044-5, C57.13
2) Power supply: AC220V±10%, 50/60Hz±10%
3) Voltage output: 0.1~180V (AC)
4) Current output: 0.001~5A(RMS)
5) Power output: 500VA
6) Maximum knee voltage measurement: 45KV
7) PT ratio error measurement: typical error <0.05%, maximum error<0.1%
8) PT phase angle measurement: maximum error < 3min
9) Memory capacity: >1000 groups test results
10) Working condition: temperature: -10ºC~50ºC, humidty: ≤90%
11) Size: 485mmx356mmx183mm, weight: <15kg
RangeErrorResolutionCurrent measurement0~10A (automatically change range in 0.1/0.4/2/10A)<±0.1%+0.01%FS/Voltage measurement0~200V (automatically change
range in 1V/10V/70V/200V)<±0.1%+0.01%FS/Turns ratio measurement1~5000<0.05%/5000~35000<0.1%/Phase measurement/±2minResolution: 0.01minWinding resistance measurement0~8kΩ (automatically change range in 2ohm/20ohm/80ohm/800ohm/
8kohm)<0.2%RDG+0.02%FSMaximum resolution: 0.1mΩTemperature measurement-50~100 Celsius degree<3 Celsius degree/CT Secondary burden0~160ohm (automatically change
range in 2ohm/20ohm/80ohm/
160ohm)<0.2%RDG+0.02%FSMaximum resolution: 0.001ohmPT Secondary burden0~80kohm (automatically change
range in 800ohm/8kohm/80kohm)<0.2%RDG+0.02%FSMaximum resolution: 0.1ohmPT ratio measurement1~10000<0.1%/10000~35000<0.2%/
Other products:
Circuit Breaker Analyzer / Contact Resistance Tester / On Load Tap Changer Tester / Circuit Breaker Vacuum Degree Tester / Insulating Oil Tester / CT PT Analyzer / Transformer Winding Resistance Tester / Sweep Frequency Response Analyzer / Transformer Load and No-load tester / Transformer Ratio Tester / Primary Current Injection Test Set / Frequency Adjustable Series Resonance Test Set / High Voltage Divider / High Voltage Generator / VLF tester / Wireless HV Phase Tester / MOA metal Oxide Arrester MOA Tester / Hipot Tester / Relay Tester / Insulation Tester / Grounding Resistance TesterPackaging & Shipping